文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

声门下分泌物引流对ICU机械通气患者综合效果的Meta分析

[Comprehensive effect of subglottic secretion drainage on patients with mechanical ventilation in ICU: a Meta-analysis].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2017-01-01
一句话结论Meta分析显示声门下分泌物引流可降低VAP发生率、缩短机械通气时间和住院时间,但不降低ICU或住院死亡率。

该Meta分析纳入13项RCT共2052例ICU机械通气成人患者,比较声门下分泌物引流(SSD)与非SSD。结果显示SSD组VAP发生率降低(RR=0.54,95%CI 0.46-0.64,P<0.00001),机械通气时间缩短(MD=-3.29,95%CI -4.53至-2.05,P<0.00001),住院时间缩短(MD=-4.27,95%CI -7.36至-1.18,P=0.007),但ICU或住院死亡率无显著差异(RR=0.89,95%CI 0.73-1.09,P=0.25)。敏感性分析结果稳定,漏斗图未发现明显发表偏倚。

要点

  • SSD降低ICU机械通气成人患者VAP发生率(RR=0.54,95%CI 0.46-0.64,P<0.00001)。
  • SSD缩短机械通气时间(MD=-3.29,95%CI -4.53至-2.05,P<0.00001)。
  • SSD缩短住院时间(MD=-4.27,95%CI -7.36至-1.18,P=0.007)。
  • SSD对ICU或住院死亡率无显著影响(RR=0.89,95%CI 0.73-1.09,P=0.25)。
  • 敏感性分析显示机械通气时间结果稳定,漏斗图未发现明显发表偏倚。

适用人群与场景

  • ICU中接受机械通气的成人患者。

研究设计与关键结果

  • 研究类型:Meta分析,纳入13项随机对照试验(RCT),共2052例患者,干预组1021例,对照组1031例。
  • 主要终点:VAP发生率,SSD组 vs 对照组 RR=0.54(95%CI 0.46-0.64,P<0.00001)。
  • 关键次要终点:机械通气时间 MD=-3.29(95%CI -4.53至-2.05,P<0.00001);住院时间 MD=-4.27(95%CI -7.36至-1.18,P=0.007);ICU或住院死亡率 RR=0.89(95%CI 0.73-1.09,P=0.25),无显著差异。
  • 敏感性分析:逐步剔除纳入文献后合并计算,机械通气时间结果稳定,个体研究结果对总体结果无显著影响。
  • 发表偏倚:漏斗图显示纳入研究对称,未发现明显发表偏倚。

证据类型、等级与局限

  • 证据类型:随机对照试验(RCT)的Meta分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为SSD确实有降低VAP发生率、缩短机械通气时间和住院时间的作用,但对降低死亡率无显著效果。
  • 作者认为有效使用SSD是预防VAP的重要措施,有必要客观评估SSD的临床效果。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To systematically evaluate the comprehensive effect of subglottic secretion drainage (SSD) on patients with mechanical ventilation (MV) in intensive care unit (ICU).

METHODS: The randomized controlled clinical trials (RCTs) comparing SSD (intervention group) versus non-SSD (control group) in adult patients with MV in ICU was collected through the databases such as the PubMed database of the National Library of Medicine, CNKI, Wanfang database and the Chinese journal of science and technology database (VIP). The subjects were ICU patients with MV, and the retrieval time ranged from January 2006 to December 2016. Two reviewers independently screened the studies according to the inclusive and exclusive criteria, extracted the data, and assessed the quality. Then RevMan 5.3 software was used for Meta-analysis. Sensitivity analysis was performed using Stata 11.0 software. Funnel plot was used to analyze publication bias.

RESULTS: In the 1 004 documents obtained from preliminary screening, a total of 13 studies involving 2 052 patients were enrolled after excluding duplicated documents and literature did not meet the inclusion criteria, with 1 021 patients in intervention group, and 1 031 in control group. Meta-analysis showed that compared with control group, the application of SSD in patients with MV could contribute to the reduction of the incidence of ventilator-associated pneumonia [VAP; risk ratio (RR) = 0.54, 95% confidence interval (95%CI) = 0.46-0.64, P < 0.000 01], the duration of MV [mean difference (MD) = -3.29, 95%CI = -4.53 to -2.05, P < 0.000 01] and length of hospital stay (MD = -4.27, 95%CI = -7.36 to -1.18, P = 0.007) were shortened, while there was no significant difference in ICU or hospital mortality rate between the intervention group and control group (RR = 0.89, 95%CI = 0.73-1.09, P = 0.25). The sensitivity analysis for studies enrolled in Meta-analysis of MV duration showed that individual research results were stable through step remove of the included literatures and combined calculation of the remaining literature value, suggesting that individual research results were stable, and would not have a significant impact on the overall results. The results of the funnel analysis showed that there was a symmetry in the inclusion studies, and no significant publication bias was found.

CONCLUSIONS: SSD did have effect in reducing the incidence of VAP, shortening the duration of MV and length of hospital stay, while there was no significant effect on reducing mortality rate. Effective use of SSD is an important measure to prevent VAP. It is necessary to objectively evaluate the clinical effect of SSD.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Sun X, Zhang J, Jiang T, et al. [Comprehensive effect of subglottic secretion drainage on patients with mechanical ventilation in ICU: a Meta-analysis]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 28743333. doi:10.3760/cma.j.issn.2095-4352.2017.07.003