儿童钝性腹部创伤后床旁超声快速评估:多中心分析
该前瞻性多中心研究纳入14家一级儿童创伤中心、1年内就诊的16岁以下钝性腹部创伤儿童共2188例,其中829例(37.9%)接受了FAST。以CT和/或术中所见为金标准,FAST对腹腔内损伤的敏感性为27.8%、特异性为91.4%,对需急性干预的腹腔内损伤敏感性为44.4%、特异性为88.5%。FAST后CT使用率为41%,未行FAST者为46%。作者结论认为,按目前使用方式,FAST对腹腔内损伤敏感性低、会漏诊需急性干预的损伤,且很少影响儿童钝性腹部创伤的处理。
要点
- FAST对儿童钝性腹部创伤后腹腔内损伤的敏感性仅27.8%、特异性91.4%,阴性预测值76.0%,漏诊较多。
- FAST对需急性干预的腹腔内损伤敏感性44.4%、特异性88.5%、阴性预测值94.9%,仍有15例FAST阴性者接受了急性干预。
- FAST后CT使用率41%,未行FAST者为46%,FAST与CT使用率之间相关性低(r=-0.050,p<0.001)。
- 各中心FAST使用频率从0.84%到94.1%差异很大,使用频率更高的中心并未提高准确性。
- 27例FAST真阳性者中12例接受干预,全部有腹部体格检查异常;无患者在CT前接受干预。
适用人群与场景
- 14家一级儿童创伤中心、1年期间前瞻性纳入的16岁以下钝性腹部创伤儿童,共2188例,年龄7.8±4.6岁。
- 其中829例(37.9%)接受了FAST,340例FAST后接受了腹部CT。
红旗征与不能漏的情况
- FAST阴性不能排除需急性干预的腹腔内损伤:15例FAST阴性儿童接受了急性干预。
- 70例FAST假阴性中共有81处损伤。
- 27例FAST真阳性并接受干预者全部有腹部体格检查异常。
研究设计与关键结果
- 前瞻性多中心研究,14家一级儿童创伤中心,纳入16岁以下钝性腹部创伤儿童2188例,829例(37.9%)接受FAST,其中340例接受腹部CT。
- 340例中97例(29%)有腹腔内损伤,27例(7.9%)接受急性干预;FAST后CT使用率41%,未行FAST者46%。
- FAST对腹腔内损伤:敏感性27.8%、特异性91.4%、阳性预测值56.2%、阴性预测值76.0%、准确性73.2%。
- FAST对需急性干预的腹腔内损伤:敏感性44.4%、特异性88.5%、阳性预测值25.0%、阴性预测值94.9%、准确性85.0%。
- 各中心FAST使用频率0.84%~94.1%,FAST与CT使用率相关性低(r=-0.050,p<0.001),使用频率更高的中心未提高准确性。
- 27例FAST真阳性中12例接受干预,全部有腹部体格检查异常;无患者在CT前接受干预;70例假阴性中共81处损伤,15例FAST阴性者接受急性干预。
证据类型、等级与局限
- 证据类型:前瞻性多中心研究;证据等级:预后与流行病学研究level II,诊断试验或标准研究level II,治疗/护理管理研究level III。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,按目前使用方式,FAST对儿童钝性腹部创伤后腹腔内损伤敏感性低、会漏诊需急性干预的损伤,且很少影响处理。
- 各中心FAST使用频率差异大(0.84%~94.1%),使用频率更高的中心未提高准确性。
- 27例FAST真阳性并接受干预者全部有腹部体格检查异常;无患者在CT前接受干预。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: The utility of focused assessment with sonography for trauma (FAST) in children is poorly defined with considerable practice variation. Our purpose was to investigate the role of FAST for intra-abdominal injury (IAI) and IAI requiring acute intervention (IAI-I) in children after blunt abdominal trauma (BAT).
METHODS: We prospectively enrolled children younger than 16 years after BAT at 14 Level I pediatric trauma centers over a 1-year period. Patients who underwent FAST were compared with those that did not, using descriptive statistics and univariate analysis; p value less than 0.05 was considered significant. FAST test characteristics were performed using computed tomography (CT) and/or intraoperative findings as the gold standard.
RESULTS: Two thousand one hundred eighty-eight children (age, 7.8 ± 4.6 years) were included. Eight hundred twenty-nine (37.9%) received a FAST, 340 of whom underwent an abdominal CT. Ninety-seven (29%) of these 340 patients had an IAI and 27 (7.9%) received an acute intervention. CT scan utilization after FAST was 41% versus 46% among those who did not receive FAST. The frequency of FAST among centers ranged from 0.84% to 94.1%. There was low correlation between FAST and CT utilization (r = -0.050, p < 0.001). Centers that performed FAST at a higher frequency did not have improved accuracy. The test performance of FAST for IAI was sensitivity, 27.8%; specificity, 91.4%; positive predictive value, 56.2%; negative predictive value, 76.0%; and accuracy, 73.2%. There were 81 injuries among the 70 false-negative FAST. The test performance of FAST for IAI-I was sensitivity, 44.4%; specificity, 88.5%; positive predictive value, 25.0%; negative predictive value, 94.9%; and accuracy, 85.0%. Fifteen children with a negative FAST received acute interventions. Among the 27 patients with true positive FAST examinations, 12 received intervention. All had an abnormal abdominal physical examination. No patient underwent intervention before CT scan.
CONCLUSION: As currently used, FAST has a low sensitivity for IAI, misses IAI-I and rarely impacts management in pediatric BAT.
LEVEL OF EVIDENCE: Prognostic and epidemiologic study, level II; diagnostic tests or criteria study, level II; therapeutic/care management study, level III.
参考来源
- Calder BW, Vogel AM, Zhang J, et al. Focused assessment with sonography for trauma in children after blunt abdominal trauma: A multi-institutional analysis. J Trauma Acute Care Surg. 2017. PMID: 28590347. doi:10.1097/TA.0000000000001546