文献速递儿科与产科急症复苏、休克与脓毒症

提高急诊科对儿童严重脓毒症的识别:基于生命体征的电子预警与床旁临床医生识别的贡献

Improving Recognition of Pediatric Severe Sepsis in the Emergency Department: Contributions of a Vital Sign-Based Electronic Alert and Bedside Clinician Identification.
PubMed 文献 · Ann Emerg Med · 2017-06-02
一句话结论在儿科急诊,电子脓毒症预警单独识别严重脓毒症敏感性86.2%、特异性99.1%,加上床旁临床医生识别后敏感性升至99.4%,预警实施使急诊脓毒症检出率从83%升至96%。

该研究在儿科急诊开展含质量改进干预的队列研究,评估由电子脓毒症预警和床旁评估组成的脓毒症识别流程。电子预警阳性定义为脉搏率升高或低血压、存在感染担忧,且至少满足以下之一:毛细血管再充盈异常、精神状态异常或高危基础疾病。预警阳性触发团队评估或碰头会以决定是否需要启动脓毒症方案,临床医生也可根据临床担忧在预警阴性时启动评估。研究期间共182,509次急诊就诊,1,112次(1.2%)预警阳性,326例(0.3%)在24小时内因严重脓毒症接受治疗;预警单独检测严重脓毒症的敏感性86.2%、特异性99.1%、阳性预测值25.4%、阴性预测值100%,加入临床医生筛查后额外识别43例预警阴性患儿,敏感性升至99.4%、特异性99.1%;预警实施使急诊脓毒症检出率从83%升至96%。

要点

  • 电子脓毒症预警单独识别严重脓毒症敏感性86.2%(95%CI 82.0%–89.5%),特异性99.1%(95%CI 99.0%–99.2%),阴性预测值100%(95%CI 99.9%–100%)。
  • 加入床旁临床医生识别后,额外发现43例电子预警阴性的严重脓毒症患儿,敏感性升至99.4%(95%CI 97.8%–99.8%),特异性仍为99.1%(95%CI 99.1%–99.2%)。
  • 电子预警阳性预测值仅25.4%(95%CI 22.8%–28.0%),提示预警阳性需团队评估或碰头会进一步确认,而非直接诊断。
  • 电子脓毒症预警实施后,急诊严重脓毒症检出率从83%升至96%。
  • 研究期间326例(0.3%)患儿在24小时内因严重脓毒症接受治疗,1,112次(1.2%)电子预警阳性。

适用人群与场景

  • 儿科急诊就诊患儿,研究期间共182,509次急诊就诊,其中电子预警实施前86,037次、实施后96,472次。
  • 电子预警阳性定义为脉搏率升高或低血压、存在感染担忧,且至少满足以下之一:毛细血管再充盈异常、精神状态异常或高危基础疾病。

诊断标准与关键阈值

  • 电子脓毒症预警阳性:脉搏率升高或低血压,加上感染担忧,且至少满足以下之一:毛细血管再充盈异常、精神状态异常或高危基础疾病。
  • 严重脓毒症结局定义:在急诊启动脓毒症方案,或24小时内发展为严重脓毒症需入住ICU。

处置流程与药物剂量

  • 电子脓毒症预警阳性触发团队评估或碰头会,以确定是否需要启动脓毒症方案。
  • 临床医生可根据临床担忧,在电子预警阴性时启动团队评估或碰头会。

红旗征与不能漏的情况

  • 脉搏率升高或低血压伴感染担忧,且合并毛细血管再充盈异常、精神状态异常或高危基础疾病时,电子预警阳性,需团队评估或碰头会。
  • 电子预警阴性但临床医生有担忧时,仍应启动团队评估或碰头会,因此类患者中可识别出额外43例严重脓毒症患儿。

研究设计与关键结果

  • 研究设计:在儿科急诊开展含质量改进干预的队列研究,暴露为电子脓毒症预警阳性。
  • 样本量:研究期间共182,509次急诊就诊,电子预警实施前86,037次、实施后96,472次;1,112次(1.2%)电子预警阳性;326例(0.3%)在24小时内因严重脓毒症接受治疗。
  • 电子预警单独检测严重脓毒症:敏感性86.2%(95%CI 82.0%–89.5%),特异性99.1%(95%CI 99.0%–99.2%),阳性预测值25.4%(95%CI 22.8%–28.0%),阴性预测值100%(95%CI 99.9%–100%)。
  • 加入临床医生筛查后:额外识别43例电子预警阴性的严重脓毒症患儿,敏感性99.4%(95%CI 97.8%–99.8%),特异性99.1%(95%CI 99.1%–99.2%)。
  • 电子预警实施使急诊脓毒症检出率从83%升至96%。

证据类型、等级与局限

  • 证据类型:含质量改进干预的队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在儿科急诊,可将电子脓毒症预警作为严重脓毒症筛查工具,预警阳性时触发团队评估或碰头会以决定是否启动脓毒症方案。
  • 不应仅依赖电子预警:临床医生对电子预警阴性但临床担忧的患儿应启动团队评估或碰头会,因加入临床医生识别后敏感性从86.2%升至99.4%。
  • 电子预警阳性预测值25.4%,提示预警阳性不等于严重脓毒症诊断,需团队评估进一步确认。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

STUDY OBJECTIVE: Recognition of pediatric sepsis is a key clinical challenge. We evaluate the performance of a sepsis recognition process including an electronic sepsis alert and bedside assessment in a pediatric emergency department (ED).

METHODS: This was a cohort study with quality improvement intervention in a pediatric ED. Exposure was a positive electronic sepsis alert, defined as elevated pulse rate or hypotension, concern for infection, and at least one of the following: abnormal capillary refill, abnormal mental status, or high-risk condition. A positive electronic sepsis alert prompted team assessment or huddle to determine need for sepsis protocol. Clinicians could initiate team assessment or huddle according to clinical concern without positive electronic sepsis alert. Severe sepsis outcome defined as activation of the sepsis protocol in the ED or development of severe sepsis requiring ICU admission within 24 hours.

RESULTS: There were 182,509 ED visits during the study period, with 86,037 before electronic sepsis alert implementation and 96,472 afterward, and 1,112 (1.2%) positive electronic sepsis alerts. Overall, 326 patients (0.3%) were treated for severe sepsis within 24 hours. Test characteristics of the electronic sepsis alert alone to detect severe sepsis were sensitivity 86.2% (95% confidence interval [CI] 82.0% to 89.5%), specificity 99.1% (95% CI 99.0% to 99.2%), positive predictive value 25.4% (95% CI 22.8% to 28.0%), and negative predictive value 100% (95% CI 99.9% to 100%). Inclusion of the clinician screen identified 43 additional electronic sepsis alert-negative children, with severe sepsis sensitivity 99.4% (95% CI 97.8% to 99.8%) and specificity 99.1% (95% CI 99.1% to 99.2%). Electronic sepsis alert implementation increased ED sepsis detection from 83% to 96%.

CONCLUSION: Electronic sepsis alert for severe sepsis demonstrated good sensitivity and high specificity. Addition of clinician identification of electronic sepsis alert-negative patients further improved sensitivity. Implementation of the electronic sepsis alert was associated with improved recognition of severe sepsis.