缺氧后定量MRI改变可预测昏迷苏醒及出院时功能结局
该研究纳入69例心脏骤停后7天内完成MRI的患者,用半自动算法对不同ADC阈值进行全脑定量容积分析,比较定量MRI与瞳孔检查在骤停后第3、5、7天对持续昏迷和出院时功能结局(CPC 3-4为不良)的预测价值。排除撤除生命支持者后,ADC≤650×10-6m2/s时全脑弥散受限≥2.8%对出院前未能苏醒的预测特异度100%、敏感度68%,且ADC≤450×10-6mm2/s和≤650×10-6mm2/s的ROC-AUC显著优于双侧瞳孔反射消失。幸存者中ADC≤450×10-6m2/s时全脑弥散受限>0.01%对出院时不良功能结局特异度100%、敏感度46%,AUC 0.737(0.574-0.899,p=0.04)。作者认为缺氧后定量脑MRI弥散改变可能有助于预测持续昏迷和出院时不良功能结局。
要点
- 排除撤除生命支持者后,ADC≤650×10-6m2/s时全脑弥散受限≥2.8%预测出院前未能苏醒:特异度100%、敏感度68%。
- ADC≤450×10-6mm2/s和≤650×10-6mm2/s的ROC-AUC在预测未能苏醒方面显著优于双侧瞳孔反射消失。
- 幸存者中ADC≤450×10-6m2/s时全脑弥散受限>0.01%预测出院时不良功能结局(CPC 3-4):特异度100%、敏感度46%。
- ADC≤450×10-6mm2/s预测不良功能结局的ROC曲线AUC为0.737(0.574-0.899,p=0.04)。
- 目标温度管理后传统神经预后指标不可靠,瞳孔反射消失仍是预测不良结局的可靠指标。
适用人群与场景
- 心脏骤停后7天内完成MRI的69例患者。
- 预测未能苏醒的分析排除撤除生命支持的患者。
诊断标准与关键阈值
- 出院时脑功能分类(CPC)评分3-4分定义为不良结局。
- ADC≤650×10-6m2/s时全脑弥散受限≥2.8%为预测出院前未能苏醒的阈值。
- ADC≤450×10-6mm2/s时全脑弥散受限>0.01%为预测出院时不良功能结局的阈值。
红旗征与不能漏的情况
- 双侧瞳孔反射消失仍是预测不良结局的可靠指标。
研究设计与关键结果
- 研究纳入69例心脏骤停后7天内完成MRI的患者,采用半自动算法对不同ADC阈值进行全脑定量容积分析,比较定量MRI与瞳孔检查在骤停后第3、5、7天对持续昏迷和出院时功能结局的预测价值。
- 排除撤除生命支持者后,ADC≤650×10-6m2/s时全脑弥散受限≥2.8%预测出院前未能苏醒:特异度100%、敏感度68%。
- ADC≤450×10-6mm2/s和≤650×10-6mm2/s的ROC-AUC在预测未能苏醒方面显著优于双侧瞳孔反射消失。
- 幸存者中ADC≤450×10-6mm2/s时全脑弥散受限>0.01%预测出院时不良功能结局:特异度100%、敏感度46%。
- ADC≤450×10-6mm2/s预测不良功能结局的ROC曲线AUC为0.737(0.574-0.899,p=0.04)。
证据类型、等级与局限
- 证据类型:研究论文(队列研究)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,缺氧后定量脑MRI弥散改变可能有助于预测持续昏迷和出院时不良功能结局。
- 目标温度管理后传统神经预后指标不可靠,定量MRI可作为辅助预测工具。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Traditional predictors of neurological prognosis after cardiac arrest are unreliable after targeted temperature management. Absence of pupillary reflexes remains a reliable predictor of poor outcome. Diffusion-weighted imaging has emerged as a potential predictor of recovery, and here we compare imaging characteristics to pupillary exam.
METHODS: We identified 69 patients who had MRIs within seven days of arrest and used a semi-automated algorithm to perform quantitative volumetric analysis of apparent diffusion coefficient (ADC) sequences at various thresholds. Area under receiver operating characteristic curves (ROC-AUC) were estimated to compare predictive values of quantitative MRI with pupillary exam at days 3, 5 and 7 post-arrest, for persistence of coma and functional outcomes at discharge. Cerebral Performance Category scores of 3-4 were considered poor outcome.
RESULTS: Excluding patients where life support was withdrawn, ≥2.8% diffusion restriction of the entire brain at an ADC of ≤650×10-6m2/s was 100% specific and 68% sensitive for failure to wake up from coma before discharge. The ROC-AUC of ADC changes at ≤450×10-6mm2/s and ≤650×10-6mm2/s were significantly superior in predicting failure to wake up from coma compared to bilateral absence of pupillary reflexes. Among survivors, >0.01% of diffusion restriction of the entire brain at an ADC ≤450×10-6m2/s was 100% specific and 46% sensitive for poor functional outcome at discharge. The ROC curve predicting poor functional outcome at ADC ≤450×10-6mm2/s had an AUC of 0.737 (0.574-0.899, p=0.04).
CONCLUSION: Post-anoxic diffusion changes using quantitative brain MRI may aid in predicting persistent coma and poor functional outcomes at hospital discharge.
参考来源
- Reynolds AS, Guo X, Matthews E, et al. Post-anoxic quantitative MRI changes may predict emergence from coma and functional outcomes at discharge. Resuscitation. 2017. PMID: 28624592. doi:10.1016/j.resuscitation.2017.06.010
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。