文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

纤维支气管镜肺泡灌洗联合振动排痰对机械通气重症肺炎患者的疗效:286例前瞻性随机对照试验

[Effect of bronchoalveolar lavage with fiberoptic bronchoscopy combined with vibration sputum drainage on mechanically ventilated patients with severe pneumonia: a prospective randomized controlled trial in 286 patients].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2017-01-01
一句话结论在接受机械通气的重症肺炎患者中,纤维支气管镜肺泡灌洗联合振动排痰较单用灌洗更能改善氧合、降低炎症指标并缩短机械通气与ICU停留时间,但28天死亡率无显著差异。

该研究为前瞻性随机对照试验,纳入2014年1月至2016年7月湖南省人民医院ICU收治的286例接受机械通气的重症肺炎患者,随机分为对照组和观察组各143例。两组均接受敏感抗生素抗感染、病因治疗及加温湿化治疗;对照组行纤维支气管镜肺泡灌洗,观察组行肺泡灌洗联合振动排痰。治疗后2小时观察组氧合指数高于对照组、动脉血二氧化碳分压及气道阻力低于对照组;干预后24小时观察组白细胞计数、降钙素原及C反应蛋白均低于对照组。观察组治疗有效率提高、排痰量增加、机械通气时间及ICU停留时间缩短,但28天死亡率两组无显著差异。

要点

  • 机械通气重症肺炎患者中,肺泡灌洗联合振动排痰较单用灌洗在治疗后2小时氧合指数更高(379.1±20.2 mmHg vs 351.8±24.7 mmHg),动脉血二氧化碳分压及气道阻力更低(均P<0.01)。
  • 联合振动排痰组干预后24小时白细胞计数、降钙素原及C反应蛋白均低于单用灌洗组(均P<0.01)。
  • 联合振动排痰组治疗有效率95.1%(136/143)高于单用灌洗组87.4%(125/143),排痰量更多(49.2±12.5 mL vs 36.9±11.0 mL)。
  • 联合振动排痰组机械通气时间及ICU停留时间均短于单用灌洗组(6.4±3.6天 vs 9.4±2.1天;8.6±5.7天 vs 12.4±4.6天,均P<0.01)。
  • 两组28天死亡率无显著差异(观察组2.8%(4/143)vs 对照组2.1%(3/143),P>0.05)。

适用人群与场景

  • 2014年1月至2016年7月湖南省人民医院ICU收治的接受机械通气的重症肺炎患者286例,随机分为对照组和观察组各143例。

处置流程与药物剂量

  • 两组均接受敏感抗生素抗感染、病因治疗及加温湿化治疗。
  • 对照组行纤维支气管镜肺泡灌洗;观察组行纤维支气管镜肺泡灌洗联合振动排痰。

研究设计与关键结果

  • 研究类型为前瞻性随机对照试验,样本量286例(对照组143例、观察组143例),人群为ICU接受机械通气的重症肺炎患者。
  • 治疗后2小时,观察组氧合指数高于对照组(379.1±20.2 mmHg vs 351.8±24.7 mmHg),动脉血二氧化碳分压及气道阻力低于对照组(36.5±5.8 mmHg vs 45.3±6.9 mmHg;12.9±0.6 cmH2O vs 13.1±0.8 cmH2O),均P<0.01。
  • 干预后24小时,观察组白细胞计数、降钙素原及C反应蛋白均低于对照组(8.2±1.7×10⁹/L vs 12.8±3.7×10⁹/L;15.4±2.4 μg/L vs 21.8±3.1 μg/L;37.1±6.1 mg/L vs 67.2±7.2 mg/L),均P<0.01。
  • 观察组治疗有效率95.1%(136/143)高于对照组87.4%(125/143),排痰量多于对照组(49.2±12.5 mL vs 36.9±11.0 mL)。
  • 观察组机械通气时间及ICU停留时间均短于对照组(6.4±3.6天 vs 9.4±2.1天;8.6±5.7天 vs 12.4±4.6天),均P<0.01。
  • 两组28天死亡率无显著差异(观察组2.8%(4/143)vs 对照组2.1%(3/143),P>0.05)。

证据类型、等级与局限

  • 证据类型:前瞻性随机对照试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对于ICU接受机械通气的重症肺炎患者,在纤维支气管镜肺泡灌洗基础上联合振动排痰较单用灌洗可更多排痰、改善氧合与气道阻力、降低感染指标,并缩短机械通气时间和ICU停留时间;原文报告两组28天死亡率无显著差异。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the curative effect of bronchoalveolar lavage with fiberoptic bronchoscopy combined with vibration sputum drainage in the treatment of severe pneumonia patients undergoing mechanical ventilation (MV).

METHODS: A prospective randomized controlled trial was conducted. 286 severe pneumonia patients undergoing MV admitted to intensive care unit (ICU) of Hunan People's Hospital from January 2014 to July 2016 were enrolled, and they were divided into control group and observation group according to random number table, with 143 patients in each group. Patients in both groups received sensitive antibiotics for anti-infection, etiological treatment, and calefacient and humidifying treatment. The patients in the control group received bronchoalveolar lavage with fiberoptic bronchoscopy, and those in the observation group received bronchoalveolar lavage combined with vibration sputum drainage. The parameters of respiratory function and inflammation before and after treatment, curative effect, and prognosis were compared between the two groups.

RESULTS: (1) There were no significant differences in respiratory function parameters between the two groups before treatment, 2 hours after treatment, the parameters were improved in both groups. Moreover, oxygenation index (PaO2/FiO2) in observation group was significantly higher than that of control group [mmHg (1 mmHg = 0.133 kPa): 379.1±20.2 vs. 351.8±24.7], and arterial partial pressure of carbon dioxide (PaCO2) and airway resistance (Raw) were significantly lower than those of the control group [PaCO2 (mmHg): 36.5±5.8 vs. 45.3±6.9, Raw (cmH2O, 1 cmH2O = 0.098 kPa): 12.9±0.6 vs. 13.1±0.8, all P < 0.01]. (2) There were no significant differences in inflammation parameters between the two groups before treatment, 24 hours after intervention, which were significantly decreased in both groups. Moreover, white blood cell count (WBC), procalcitonin (PCT) and C-reactive protein (CRP) in the observation group were significantly lower than those of the control group [WBC (×109/L): 8.2±1.7 vs. 12.8±3.7, PCT (μg/L): 15.4±2.4 vs. 21.8±3.1, CRP (mg/L): 37.1±6.1 vs. 67.2±7.2, all P < 0.01]. (3) Compared with the control group, the treatment efficiency of observation group was improved [95.1% (136/143) vs. 87.4% (125/143)], the quantity of sputum excretion was increased (mL: 49.2±12.5 vs. 36.9±11.0), duration of MV and length of ICU stay were significantly shortened (days: 6.4±3.6 vs. 9.4±2.1, 8.6±5.7 vs. 12.4±4.6, both P < 0.01), however, there was no significantly statistical difference in 28-day mortality between control group and observation group [2.8% (4/143) vs. 2.1% (3/143), P > 0.05].

CONCLUSIONS: Compared with bronchoalveolar lavage with fiberoptic bronchoscopy alone, the treatment of bronchoalveolar lavage combined with vibration sputum drainage is more effective in sputum excretion for severe pneumonia patients undergoing MV, which could improve the respiratory function, reduce infection, shorten the duration of MV and the length of ICU stay, and improve the recovery.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Shi Z, Qin Y, Zhu Y, et al. [Effect of bronchoalveolar lavage with fiberoptic bronchoscopy combined with vibration sputum drainage on mechanically ventilated patients with severe pneumonia: a prospective randomized controlled trial in 286 patients]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 28459407. doi:10.3760/cma.j.issn.2095-4352.2017.01.014

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。