左心室舒张功能障碍对机械通气撤机的预测价值
该回顾性病例对照研究纳入65例LVEF>0.50、机械通气>48小时的外科ICU患者,分析撤机前超声心动图左心室舒张功能参数与撤机结局的关系。结果显示撤机失败率随舒张功能障碍程度加重而升高(正常16.1%、轻度44.6%、中重度76.0%,P=0.001)。撤机失败组撤机前E/A、E/Em及RSBI均高于成功组。ROC分析显示E/A>1.2预测撤机失败的AUC为0.81±0.06,侧壁E/Em>7.9的AUC为0.85±0.06,两者联合AUC为0.86±0.05,敏感度78.3%、特异度93.6%。作者认为左心室舒张功能障碍与撤机结局显著相关,联合E/A>1.2与E/Em>7.9可能识别撤机失败高危患者。
要点
- 撤机失败率随左心室舒张功能障碍程度加重而升高:正常组16.1%、轻度组44.6%、中重度组76.0%(χ²=20.240,P=0.001)。
- 撤机失败组撤机前E/A为1.47±0.08,高于撤机成功组的1.14±0.05(t=3.827,P=0.000)。
- 撤机失败组撤机前侧壁E/Em为10.26±0.52,高于撤机成功组的7.28±0.41(t=4.535,P=0.000)。
- 撤机前E/A>1.2预测撤机失败的AUC为0.81±0.06,敏感度82.6%、特异度81.4%,高于RSBI的AUC 0.70±0.07。
- 撤机前E/A>1.2联合侧壁E/Em>7.9预测撤机失败的AUC为0.86±0.05,敏感度78.3%、特异度93.6%。
适用人群与场景
- LVEF>0.50、机械通气时间超过48小时、入住外科ICU的患者。
- 研究纳入2014年6月至2016年12月中日友好医院外科ICU的65例患者。
诊断标准与关键阈值
- 左心室舒张功能分级标准:正常、轻度(1级)、中重度(2-3级)。
- 撤机前E/A>1.2预测撤机失败,AUC 0.81±0.06,敏感度82.6%,特异度81.4%。
- 撤机前侧壁E/Em>7.9预测撤机失败,AUC 0.85±0.06,敏感度91.3%,特异度80.7%。
- 撤机前E/A>1.2联合侧壁E/Em>7.9预测撤机失败,AUC 0.86±0.05,敏感度78.3%,特异度93.6%。
研究设计与关键结果
- 研究类型为回顾性病例对照研究,纳入65例LVEF>0.50、机械通气>48小时的外科ICU患者,28例(43.1%)撤机失败,其中22例首次SBT失败、6例48小时内再插管。
- 左心室舒张功能正常31例、轻度功能障碍9例、中重度功能障碍25例,撤机失败率分别为16.1%、44.6%、76.0%(χ²=20.240,P=0.001)。
- 撤机失败组与撤机成功组撤机前比较:DTE 180.4±5.1 s vs. 196.8±4.0 s(t=2.567,P=0.013);E/A 1.47±0.08 vs. 1.14±0.05(t=3.827,P=0.000);侧壁E/Em 10.26±0.52 vs. 7.28±0.41(t=4.535,P=0.000);室间隔E/Em 10.08±0.58 vs. 8.16±0.40(t=2.797,P=0.007);平均E/Em 10.17±0.48 vs. 7.72±0.35(t=4.231,P=0.000);RSBI 61.7±3.6 vs. 50.6±2.7(t=2.507,P=0.015)。
- ROC分析显示撤机前E/A>1.2预测撤机失败的AUC为0.81±0.06,敏感度82.6%、特异度81.4%;侧壁E/Em>7.9的AUC为0.85±0.06,敏感度91.3%、特异度80.7%;两者联合AUC为0.86±0.05,敏感度78.3%、特异度93.6%;E/A与侧壁E/Em的AUC均高于RSBI(0.70±0.07)。
证据类型、等级与局限
- 证据类型:回顾性病例对照研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在LVEF>0.50的危重患者中,左心室舒张功能障碍与撤机结局显著相关。
- 作者认为,联合E/A>1.2与E/Em>7.9可能识别撤机失败高危患者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the predictive value of left ventricular diastolic function on mechanical ventilation weaning in patients with left ventricular ejection fraction (LVEF) > 0.50.
METHODS: A retrospective case control study was conducted. Sixty-five patients with LVEF > 0.50 undergoing mechanical ventilation for more than 48 hours admitted to surgery intensive care unit (ICU) of China-Japan Friendship Hospital from June 2014 to December 2016 were enrolled. The clinical data and parameters of echocardiography before spontaneous breathing trial (SBT) were collected. The possible relationship between left ventricular diastolic function and the results of weaning was analyzed according to analysis of blood flow filling parameters of mitral valve orifice. According to the grading standard of left ventricular diastolic function, the patients were divided into normal, mild (level 1) and moderate to severe (level 2-3) groups, and the outcomes of weaning were compared among the groups. Then patients were also divided into two groups of weaning successfully and weaning failure, and the clinical data and left ventricular diastolic function parameters of patients were compared between the two groups. The predictive value of left ventricular diastolic function on results of weaning was evaluated with receiver operating characteristic curve (ROC).
RESULTS: Sixty-five patients were enrolled and 28 patients (43.1%) failed weaning, 22 patients failed the first SBT and 6 required reintubation within 48 hours, 31 of the patients presented normal left ventricular diastolic function, 9 of patients presented mild diastolic dysfunction, and 25 of them presented moderate to severe diastolic dysfunction. So with the gradual increase of the severity of diastolic dysfunction, the rate of weaning failure was gradually increased, which was 16.1%, 44.6% and 76.0% respectively (χ 2 = 20.240, P = 0.001). Patients who failed weaning presented evidence of increased left ventricular filling pressures at pre-SBT, by demonstrating decreased deceleration time of E (DTE, s: 180.4±5.1 vs. 196.8±4.0, t = 2.567, P = 0.013), increased left ventricular mitral valve diastolic early and late filling velocity ratio (E/A: 1.47±0.08 vs. 1.14±0.05, t = 3.827, P = 0.000), increased lateral, septal and averaged left ventricular mitral valve diastolic early velocity and maximal velocity of mitral annulus in early diastolic velocity ratio (E/Em: 10.26±0.52 vs. 7.28±0.41, t = 4.535, P = 0.000; 10.08±0.58 vs. 8.16±0.40, t = 2.797, P = 0.007; 10.17±0.48 vs. 7.72±0.35, t = 4.231, P = 0.000), and the rapid shallow breathing index (RSBI) was also increased significantly (61.7±3.6 vs. 50.6±2.7, t = 2.507, P = 0.015). It was shown by ROC curve analysis that the basic left ventricular diastolic function at pre-SBT had the diagnostic performance in predicting the outcome of weaning from mechanical ventilation, especially E/A and lateral E/Em. Pre-SBT values of E/A greater than 1.2 and lateral E/Em greater than 7.9 predicted weaning failure with an area under the ROC curve (AUC), sensitivity, and specificity of 0.81±0.06 and 0.85±0.06, 82.6% and 91.3%, 81.4% and 80.7%, respectively, and the AUC was higher than RSBI (0.70±0.07). The AUC of combination of E/A > 1.2 and lateral E/Em > 7.9 predicting weaning failure was 0.86±0.05 with a sensitivity of 78.3% and a specificity of 93.6%.
CONCLUSIONS: The results suggest that left ventricular diastolic dysfunction is significantly associated with weaning outcome in critical patients with LVEF > 0.50. The combination of E/A ratio greater than 1.2 and E/Em ratio greater than 7.9 may identify patients at high risk of weaning failure.
参考来源
- Wang H, Ma M, Chen D, et al. [Predictive value of left ventricular diastolic dysfunction on mechanical ventilation weaning]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 28524029. doi:10.3760/cma.j.issn.2095-4352.2017.05.006
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。