在人体尸体模型中,使用ResQPUMP进行心肺复苏时,静态按压和减压会改变胸部顺应性,表现为胸廓前后径高度的变化

Chest compliance is altered by static compression and decompression as revealed by changes in anteroposterior chest height during CPR using the ResQPUMP in a human cadaver model.
PubMed 文献 · Resuscitation · 2017-04-28
一句话结论尸体模型显示,5分钟自动心肺复苏后胸廓前后径位移显著增大,提示胸部顺应性随时间增加,可能需要调整按压和减压力度以优化心肺复苏。

该研究在9具新近死亡(未冷冻)的人体尸体上,使用手动ACD-CPR装置(ResQPUMP,ZOLL)在5分钟自动心肺复苏前后施加静态按压(30、40、50kg)和减压(-10、-15kg)力,并通过侧位胸片测量胸廓前后径变化。结果发现,5分钟心肺复苏后,各力度下的胸廓前后径位移均显著增大(p<0.05),例如50kg按压时从4.3±1.0 cm增至6.3±1.9 cm。作者认为胸部顺应性随时间显著增加,提示可能需要调整按压和减压力度以优化心肺复苏。

要点

  • 在9具人体尸体中,5分钟自动心肺复苏后,50kg按压产生的胸廓前后径位移从4.3±1.0 cm增至6.3±1.9 cm(p<0.05)。
  • 30kg按压时胸廓前后径位移从2.1±1.2 cm增至3.7±1.4 cm,40kg从2.9±1.3 cm增至4.9±1.6 cm(均p<0.05)。
  • -10kg减压时胸廓前后径位移从1.0±0.8 cm增至2.3±0.9 cm,-15kg从1.8±0.6 cm增至2.7±1.1 cm(均p<0.05)。
  • 作者认为,胸部顺应性随时间显著增加,提示可能需要调整按压和减压力度以优化心肺复苏。

适用人群与场景

  • 新近死亡(未冷冻)的人体尸体,共9具,用于心肺复苏研究。

研究设计与关键结果

  • 研究类型为人体尸体模型研究,样本量9具尸体。
  • 干预:使用手动ACD-CPR装置(ResQPUMP,ZOLL)在5分钟自动心肺复苏前后施加静态按压(30、40、50kg)和减压(-10、-15kg)力。
  • 主要终点:胸廓前后径位移变化。5分钟心肺复苏前,30kg按压时位移为2.1±1.2 cm,40kg为2.9±1.3 cm,50kg为4.3±1.0 cm,-10kg减压为1.0±0.8 cm,-15kg为1.8±0.6 cm。
  • 5分钟心肺复苏后,胸廓前后径位移显著增大(p<0.05):30kg按压为3.7±1.4 cm,40kg为4.9±1.6 cm,50kg为6.3±1.9 cm,-10kg减压为2.3±0.9 cm,-15kg为2.7±1.1 cm。

证据类型、等级与局限

  • 证据类型:人体尸体模型研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,胸部顺应性随时间显著增加,提示可能需要调整按压和减压力度以优化心肺复苏。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Chest compliance plays a fundamental role in the generation of circulation during cardiopulmonary resuscitation (CPR). To study potential changes in chest compliance over time, anterior posterior (AP) chest height measurements were performed on newly deceased (never frozen) human cadavers during CPR before and after 5min of automated CPR. We tested the hypothesis that after 5min of CPR chest compliance would be significantly increased.

METHODS: Static compression (30, 40, and 50kg) and decompression forces (-10, -15kg) were applied with a manual ACD-CPR device (ResQPUMP, ZOLL) before and after 5min of automated CPR. Lateral chest x-rays were obtained with multiple reference markers to assess changes in AP distance.

RESULTS: In 9 cadavers, changes (mean±SD) in the AP distance (cm) during the applied forces were 2.1±1.2 for a compression force of 30kg, 2.9±1.3 for 40kg, 4.3±1.0 for 50kg, 1.0±0.8 for a decompression force of -10kg and 1.8±0.6 for -15kg. After 5min of automated CPR, AP excursion distances were significantly greater (p<0.05). AP distance increased to 3.7±1.4 for a compression force of 30kg, 4.9±1.6 for 40kg, 6.3±1.9 for 50kg, 2.3±0.9 for -10kg of lift and 2.7±1.1 for -15kg of lift.

CONCLUSIONS: These data demonstrate chest compliance increases significantly over time as demonstrated by the significant increase in the measured AP distance after 5min of CPR. These findings suggest that adjustments in compression and decompression forces may be needed to optimize CPR over time.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Segal N, Robinson AE, Berger PS, et al. Chest compliance is altered by static compression and decompression as revealed by changes in anteroposterior chest height during CPR using the ResQPUMP in a human cadaver model. Resuscitation. 2017. PMID: 28461164. doi:10.1016/j.resuscitation.2017.04.032

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。