AHA心肺复苏质量指南依从性与院外心脏骤停临床结局的关联
该研究为对Resuscitation Outcomes Consortium Epistry-Cardiac Arrest数据库前瞻性收集数据的二次分析,纳入4年期间(截至2015年6月)的19,568份除颤器记录。按2015年AHA指南定义指南依从性心肺复苏为:胸外按压比例>0.8、按压频率100-120次/分、按压深度50-60mm、除颤前暂停<10秒。校正Utstein变量后,整体符合全部质量指标的复苏与参照标准相比,出院生存无显著差异(OR 1.26;95%CI 0.80,1.97);但在≥10分钟院前复苏后恢复自主循环的亚组(n=4,158)中,依从性与生存显著改善相关(OR 2.17;95%CI 1.11,4.27),神经功能完好生存(MRS≤3)也相似(OR 3.03;95%CI 1.12,8.20)。作者认为提高整体指南依从性的策略可能对院外心脏骤停结局有显著影响。
要点
- 整体符合AHA心肺复苏质量指南(胸外按压比例>0.8、频率100-120次/分、深度50-60mm、除颤前暂停<10秒)与出院生存无显著关联(OR 1.26;95%CI 0.80,1.97)。
- 在≥10分钟院前复苏后恢复自主循环的患者(n=4,158)中,指南依从性与出院生存显著改善相关(OR 2.17;95%CI 1.11,4.27)。
- 同一亚组中,指南依从性与神经功能完好生存(MRS≤3)显著改善相关(OR 3.03;95%CI 1.12,8.20)。
- 研究为观察性设计,整体依从性与结局的关联可能受早期恢复自主循环病例的混杂影响,故进行了预先规定的亚组分析。
- 作者认为,提高整体指南依从性的策略可能对院外心脏骤停结局有显著影响。
适用人群与场景
- 院外心脏骤停患者,数据来自Resuscitation Outcomes Consortium Epistry-Cardiac Arrest数据库,共19,568份除颤器记录(4年期间,截至2015年6月)。
- 预先规定的亚组分析纳入院前急救复苏≥10分钟后恢复自主循环的患者(n=4,158)。
诊断标准与关键阈值
- 按2015年AHA指南定义指南依从性心肺复苏:胸外按压比例>0.8、胸外按压频率100-120次/分、胸外按压深度50-60mm、除颤前暂停<10秒。
研究设计与关键结果
- 研究类型:对前瞻性收集数据的二次分析(观察性研究),样本量19,568份除颤器记录,数据收集4年期间截至2015年6月。
- 主要模型(胸外按压比例、频率、深度)中,符合全部心肺复苏质量指标(指南依从)与参照标准(未达到全部指标)相比,出院生存无显著差异(OR 1.26;95%CI 0.80,1.97)。
- 亚组分析(≥10分钟院前复苏后恢复自主循环,n=4,158):指南依从组出院生存显著高于参照标准(OR 2.17;95%CI 1.11,4.27)。
- 同一亚组中,指南依从组神经功能完好生存(MRS≤3)显著高于参照标准(OR 3.03;95%CI 1.12,8.20)。
证据类型、等级与局限
- 证据类型:观察性研究(对前瞻性收集数据的二次分析)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,提高整体指南依从性的策略可能对院外心脏骤停结局有显著影响。
- 在≥10分钟院前复苏后恢复自主循环的患者中,符合AHA心肺复苏质量指南与出院生存及神经功能完好生存改善相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Measures of chest compression fraction (CCF), compression rate, compression depth and pre-shock pause have all been independently associated with improved outcomes from out-of-hospital (OHCA) cardiac arrest. However, it is unknown whether compliance with American Heart Association (AHA) guidelines incorporating all the aforementioned metrics, is associated with improved survival from OHCA.
METHODS: We performed a secondary analysis of prospectively collected data from the Resuscitation Outcomes Consortium Epistry-Cardiac Arrest database. As per the 2015 American Heart Association (AHA) guidelines, guideline compliant cardiopulmonary resuscitation (CPR) was defined as CCF >0.8, chest compression rate 100-120/minute, chest compression depth 50-60mm, and pre-shock pause <10s. Multivariable logistic regression models controlling for Utstein variables were used to assess the relationship between global guideline compliance and survival to hospital discharge and neurologically intact survival with MRS ≤3. Due to potential confounding between CPR quality metrics and cases that achieved early ROSC, we performed an a priori subgroup analysis restricted to patients who obtained ROSC after ≥10min of EMS resuscitation.
RESULTS: After allowing for study exclusions, 19,568 defibrillator records were collected over a 4-year period ending in June 2015. For all reported models, the reference standard included all cases who did not meet all CPR quality benchmarks. For the primary model (CCF, rate, depth), there was no significant difference in survival for resuscitations that met all CPR quality benchmarks (guideline compliant) compared to the reference standard (OR 1.26; 95% CI: 0.80, 1.97). When the dataset was restricted to patients obtaining ROSC after ≥10min of EMS resuscitation (n=4,158), survival was significantly higher for those resuscitations that were guideline compliant (OR 2.17; 95% CI: 1.11, 4.27) compared to the reference standard. Similar findings were obtained for neurologically intact survival with MRS ≤3 (OR 3.03; 95% CI: 1.12, 8.20).
CONCLUSIONS: In this observational study, compliance with AHA guidelines for CPR quality was not associated with improved outcomes from OHCA. Conversely, when restricting the cohort to those with late ROSC, compliance with guidelines was associated with improved clinical outcomes. Strategies to improve overall guideline compliance may have a significant impact on outcomes from OHCA.
参考来源
- Cheskes S, Schmicker RH, Rea T, et al. The association between AHA CPR quality guideline compliance and clinical outcomes from out-of-hospital cardiac arrest. Resuscitation. 2017. PMID: 28476474. doi:10.1016/j.resuscitation.2017.05.003
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。