指南与共识儿科与产科急症重症综合管理与镇静镇痛

新生儿重症监护病房声级显著超过推荐标准,暖箱内尤甚

Sound levels in a neonatal intensive care unit significantly exceeded recommendations, especially inside incubators.
指南 / 共识 · Acta Paediatr · 2017-06-05
一句话结论法国NICU实测平均Leq 60.4 dBA、Lmax 89.1 dBA,均超过AAP 2007推荐值(45、65 dBA),暖箱内Leq比室内高8 dBA。

本研究在2008年建成的法国新生儿重症监护病房(NICU)17间单人或双人房间内,每间放置两个剂量计(一个在暖箱内、一个在暖箱外),进行24小时声级测量,指标包括等效连续声级(Leq)、最大声级(Lmax)和10%测量时间内超过的声级(L10),并与2007年美国儿科学会(AAP)推荐值比较。结果显示平均Leq、L10、Lmax分别为60.4、62.1、89.1 dBA,均超过AAP推荐的45、50、65 dBA(p<0.001);暖箱内Leq比室内高8 dBA(p<0.001)。除受孕龄低于32周外,新生儿特征、环境或医疗护理均与声级升高无关。作者认为需要多管齐下的策略改善声环境,保护新生儿感觉发育。

要点

  • NICU实测平均Leq 60.4 dBA、L10 62.1 dBA、Lmax 89.1 dBA,分别超过AAP推荐值45、50、65 dBA(p<0.001)。
  • 暖箱内Leq比房间内高8 dBA(p<0.001),暖箱并非隔声保护环境。
  • 除受孕龄低于32周外,新生儿特征、环境及医疗护理均未显示与声级升高相关。
  • 作者结论:声级显著超过AAP推荐,暖箱内尤甚,需多管齐下策略改善声环境以保护新生儿感觉发育。

适用人群与场景

  • 2008年建成的法国NICU中17间单人或双人房间内的新生儿。

诊断标准与关键阈值

  • 对照标准为2007年美国儿科学会(AAP)推荐值:Leq 45 dBA、L10 50 dBA、Lmax 65 dBA。

研究设计与关键结果

  • 研究类型为NICU声级测量研究,在17间单人或双人房间每间安装两个剂量计(一个在暖箱内、一个在暖箱外),进行24小时测量,指标为Leq、Lmax和L10。
  • 平均Leq 60.4 dBA、L10 62.1 dBA、Lmax 89.1 dBA,分别超过AAP推荐值45、50、65 dBA(p<0.001)。
  • 暖箱内Leq显著高于房间内,高8 dBA(p<0.001)。
  • 除受孕龄低于32周外,新生儿特征、环境或医疗护理均与声级升高无相关性。

证据类型、等级与局限

  • 证据类型:NICU声级测量研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为声级显著超过AAP推荐,暖箱内尤甚,需要多管齐下的策略改善声环境并保护新生儿感觉发育。

指南或共识出处

  • 2007年美国儿科学会(AAP)推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: This study measured sound levels in a 2008 built French neonatal intensive care unit (NICU) and compared them to the 2007 American Academy of Pediatrics (AAP) recommendations. The ultimate aim was to identify factors that could influence noise levels.

METHODS: The study measured sound in 17 single or double rooms in the NICU. Two dosimeters were installed in each room, one inside and one outside the incubators, and these conducted measurements over a 24-hour period. The noise metrics measured were the equivalent continuous sound level (Leq ), the maximum noise level (Lmax ) and the noise level exceeded for 10% of the measurement period (L10 ).

RESULTS: The mean Leq , L10 and Lmax were 60.4, 62.1 and 89.1 decibels (dBA), which exceeded the recommended levels of 45, 50 and 65 dBA (p < 0.001), respectively. The Leq inside the incubator was significantly higher than in the room (+8 dBA, p < 0.001). None of the newborns' characteristics, the environment or medical care was correlated to an increased noise level, except for a postconceptional age below 32 weeks.

CONCLUSION: The sound levels significantly exceeded the AAP recommendations, particularly inside incubators. A multipronged strategy is required to improve the sound environment and protect the neonates' sensory development.

来源:Acta Paediatr,查看原文。版权归原作者所有。

参考来源

  1. Parra J, de Suremain A, Berne Audeoud F, et al. Sound levels in a neonatal intensive care unit significantly exceeded recommendations, especially inside incubators. Acta Paediatr. 2017. PMID: 28477430. doi:10.1111/apa.13906

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。