46岁男性双肺再移植后出现呼吸困难、低氧血症及影像学不对称

A 46-Year-Old Man With Dyspnea, Hypoxemia, and Radiographic Asymmetry After Redo Bilateral Lung Transplantation.
PubMed 文献 · Chest · 2017-01-01
一句话结论双肺再移植后出现持续肺动脉高压伴低氧血症,需进一步诊断评估。

一名46岁男性因初次移植后3.5年快速进展的闭塞性细支气管炎综合征接受双肺序贯再移植。术中因新植入左肺再灌注后肺动脉压升高而启动体外循环以完成右肺植入。术后转入胸科ICU时气管插管镇静状态,吸入氧浓度100%、呼气末正压10 cm H2O、吸入一氧化氮20 ppm下血氧饱和度92%。Swan-Ganz导管测得平均肺动脉压33 mm Hg、肺动脉收缩压63 mm Hg,持续升高,促使进一步诊断评估。

要点

  • 双肺再移植术后转入ICU时,在吸入氧浓度100%、呼气末正压10 cm H2O、吸入一氧化氮20 ppm条件下血氧饱和度仅92%。
  • Swan-Ganz导管测得平均肺动脉压33 mm Hg、肺动脉收缩压63 mm Hg,且持续升高。
  • 术中因新植入左肺再灌注后肺动脉压升高而启动体外循环以完成右肺植入。
  • 术后肺动脉压持续升高促使进一步诊断评估。

适用人群与场景

  • 46岁男性,因初次肺移植后3.5年快速进展的闭塞性细支气管炎综合征接受双肺序贯再移植。
  • 术后转入胸科ICU,气管插管、镇静状态。

处置流程与药物剂量

  • 术中:双腔气管插管、单右肺通气下植入左肺;左肺再灌注后肺动脉压升高,启动体外循环以完成右肺植入;右肺植入再灌注后脱离体外循环,关胸后转入胸科ICU。
  • ICU:气管插管镇静,吸入氧浓度100%、呼气末正压10 cm H2O、吸入一氧化氮20 ppm。
  • 放置Swan-Ganz导管于右颈内静脉,测得平均肺动脉压33 mm Hg、肺动脉收缩压63 mm Hg;因持续升高行进一步诊断评估。

红旗征与不能漏的情况

  • 术后肺动脉压持续升高(平均肺动脉压33 mm Hg、肺动脉收缩压63 mm Hg),促使进一步诊断评估。
  • 吸入氧浓度100%、呼气末正压10 cm H2O、吸入一氧化氮20 ppm下血氧饱和度仅92%。

证据类型、等级与局限

  • 病例报告。
  • 局限:原文未报告局限性

对床旁实践的改变

  • 双肺再移植术后出现持续肺动脉高压伴低氧血症时,需按原文所述进行进一步诊断评估。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「研究设计与关键结果」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

A 46-year-old man underwent redo bilateral sequential lung transplantation for rapidly progressive bronchiolitis obliterans syndrome that developed 3.5 years after initial transplantation. In the operating room, he was sedated and intubated with a dual lumen endotracheal tube with subsequent single right-lung ventilation and left allograft implantation. His pulmonary arterial pressure became elevated with reperfusion of the newly implanted left lung, which required initiation of cardiopulmonary bypass to facilitate implantation of the right lung. After implantation and reperfusion of the right lung, the patient was weaned from cardiopulmonary bypass. His chest was closed and he was transferred to the thoracic intensive care unit. On arrival to the intensive care unit, the patient was intubated, sedated, and had an oxygen saturation of 92% on a fraction of inspired oxygen of 100%, positive end-expiratory pressure of 10 cm H2O, and 20 parts per million of inhaled nitric oxide. He had a Swan-Ganz catheter in the right internal jugular vein that measured a mean pulmonary arterial pressure of 33 mm Hg and a pulmonary arterial systolic pressure of 63 mm Hg, which remained persistently elevated and prompted further diagnostic evaluation.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Tokman S, Smith MA, Hashimi AS, et al. A 46-Year-Old Man With Dyspnea, Hypoxemia, and Radiographic Asymmetry After Redo Bilateral Lung Transplantation. Chest. 2017. PMID: 28390643. doi:10.1016/j.chest.2016.09.013

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。