重症烧伤患者氧耗量变化测量:Fick法与间接测热法可否互换
这项前瞻性观察性单中心研究纳入22例伴循环功能不全和高乳酸血症(>2 mmol/L)的危重烧伤患者,均在镇静通气下接受经肺热稀释法心输出量监测,并在液体负荷前后同步测量Fick法氧耗量(VO2Fick)与Haldane间接测热法氧耗量(VO2Haldane)。共获得44对测量值,各时间点VO2Haldane中位数均显著高于VO2Fick。两种方法测得的氧耗量变化百分比(ΔVO2Fick与ΔVO2Haldane)相关性差(r=0.06,P=0.77),平均偏倚8.6%,一致性界限为-75.7%至92.9%。作者结论认为,在此条件下两者不可互换。
要点
- 液体负荷前VO2Haldane中位数126(103-192)mL O2/min/m显著高于VO2Fick 90(66-149)mL O2/min/m(P=0.004)。
- 液体负荷后VO2Haldane中位数129(105-189)mL O2/min/m显著高于VO2Fick 80(54-119)mL O2/min/m(P=0.001)。
- ΔVO2Fick与ΔVO2Haldane(%)相关性差,r=0.06(P=0.77),平均偏倚8.6%,一致性界限-75.7%至92.9%。
- 在伴循环功能不全和高乳酸血症(>2 mmol/L)的危重烧伤患者中,ΔVO2Haldane与ΔVO2Fick(%)不可互换。
适用人群与场景
- 连续纳入的22例伴循环功能不全和高乳酸血症(>2 mmol/L)、需要液体负荷的危重烧伤患者。
- 所有患者均接受经肺热稀释技术心输出量监测,并处于通气镇静状态;测量在静息及血流动力学稳定至少1小时条件下进行。
诊断标准与关键阈值
- 高乳酸血症定义为乳酸>2 mmol/L;液体负荷指需要液体负荷的临床状态。
研究设计与关键结果
- 前瞻性观察性单中心研究,纳入22例危重烧伤患者,共获得44对氧耗量测量值。
- 液体负荷前VO2Haldane中位数126(103-192)mL O2/min/m vs VO2Fick 90(66-149)mL O2/min/m,P=0.004。
- 液体负荷后VO2Haldane中位数129(105-189)mL O2/min/m vs VO2Fick 80(54-119)mL O2/min/m,P=0.001。
- ΔVO2Fick与ΔVO2Haldane(%)相关性差,r=0.06(P=0.77);平均偏倚8.6%,一致性界限-75.7%至92.9%。
证据类型、等级与局限
- 证据类型:前瞻性观察性单中心研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,在伴循环功能不全和高乳酸血症的危重烧伤患者中,ΔVO2Haldane与ΔVO2Fick(%)不可互换。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the interchangeability of oxygen consumption variations measured with the Fick equation (ΔVO2Fick) and indirect calorimetry (ΔVO2Haldane) in critically ill burns patients.
METHODS: Prospective observational single-center study conducted in a university hospital. Twenty-two consecutive burns patients with circulatory insufficiency and hyperlactatemia (>2 mmol/L) who required a fluid challenge (FC) were included. All patients had cardiac output monitoring (transpulmonary thermodilution technique) and were ventilated and sedated. Simultaneous measurements of VO2Fick and VO2Haldane were performed before and immediately after the FC, at rest, and in hemodynamic conditions stabilized for at least 1 h. VO2Fick and VO2Haldane were measured, respectively, with the standard formulae (using arterial and central venous saturation measured with a blood gas analyzer) and with a metabolic monitor.
RESULTS: Forty-four paired measurements of VO2 were obtained. At each timepoint, the median (interquartile range, 25-75) VO2Haldane values were significantly higher than the median VO2Fick values (126 (103-192) vs. 90 (66-149) mL O2/min/m (P = 0.004) before FC and 129 (105-189) vs. 80 (54-119) mL O2/min/m (P = 0.001) after FC). Correlation between the ΔVO2Fick and the ΔVO2Haldane (%) measurements was poor, with an r = 0.06, (P = 0.77). The mean bias was 8.6% [limits of agreement (LOA): -75.7%, 92.9%].
CONCLUSIONS: Analysis of agreement showed poor concordance for the ΔVO2Haldane and the ΔVO2Fick (%) with a low mean bias but large and clinically unacceptable LOA. ΔVO2Haldane and ΔVO2Fick (%) are not interchangeable in these conditions.
参考来源
- Soussi S, Vallée F, Roquet F, et al. Measurement of Oxygen Consumption Variations in Critically Ill Burns Patients: Are the Fick Method and Indirect Calorimetry Interchangeable? Shock. 2017. PMID: 28452908. doi:10.1097/SHK.0000000000000885
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。