使用临床可及工具测量ICU声级与睡眠中断:一项前瞻性多中心观察研究

Using Clinically Accessible Tools to Measure Sound Levels and Sleep Disruption in the ICU: A Prospective Multicenter Observational Study.
PubMed 文献 · Crit Care Med · 2017-01-01
一句话结论在39个ICU中,患者暴露于高 sound levels(最大78 dB、平均62 dB)和显著睡眠中断(中位清醒3小时),与是否已有睡眠政策无关。

该前瞻性多中心观察研究在2015年两个时间点调查了澳大利亚和新西兰39个ICU的539例16岁以上患者,用个人移动设备下载的应用程序测量1分钟环境声音,并由床边护士记录患者夜间总清醒时间和觉醒次数。结果显示最大声级78 dB(SD 9)、平均声级62 dB(SD 8);有睡眠政策/方案的ICU最大声级反而更高(81 dB vs 77 dB,平均差4 dB,95%CI 0-2,p<0.001)。无论单间 occupancy、机械通气状态或疾病严重程度,声级无显著差异。护士可在15分钟间隔记录睡眠评估,中位清醒时间3小时(IQR 1-4),中位长时间中断次数3次(IQR 2-5)。结论认为患者普遍暴露于高声级和显著睡眠中断,简单可及工具可用于未来研究和临床实践。

要点

  • 在39个ICU的539例患者中,最大声级78 dB(SD 9),平均声级62 dB(SD 8)。
  • 有睡眠政策/方案的ICU最大声级81 dB(95%CI 79-83) vs 无睡眠政策/方案的ICU 77 dB(95%CI 77-78),平均差4 dB(95%CI 0-2),p<0.001。
  • 单间 occupancy、机械通气状态或疾病严重程度与声级无显著差异。
  • 床边护士可在15分钟间隔记录睡眠评估;中位清醒时间3小时(IQR 1-4),中位长时间中断次数3次(IQR 2-5)。
  • 简单可及工具测量声级和睡眠可促进未来研究,并可能可行地融入临床实践。

适用人群与场景

  • 澳大利亚和新西兰ICU中2015年两个点患病率研究日占用ICU床位的所有16岁及以上患者。

研究设计与关键结果

  • 研究类型:横断面观察研究;样本量539例;39个ICU;人群为澳大利亚和新西兰ICU中16岁及以上占用ICU床位的患者。
  • 干预:用个人移动设备下载的应用程序测量1分钟环境声音;床边护士记录患者夜间总清醒时间和觉醒次数。
  • 主要结果:最大声级78 dB(SD 9),平均声级62 dB(SD 8)。
  • 有睡眠政策/方案的ICU最大声级81 dB(95%CI 79-83) vs 无睡眠政策/方案的ICU 77 dB(95%CI 77-78),平均差4 dB(95%CI 0-2),p<0.001。
  • 单间 occupancy、机械通气状态或疾病严重程度与声级无显著差异。
  • 所有39个ICU的临床护理人员均能以15分钟间隔记录睡眠评估;中位清醒时间3小时(IQR 1-4),中位长时间中断次数3次(IQR 2-5)。

证据类型、等级与局限

  • 证据类型:横断面观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论认为,患者暴露于高声级和显著睡眠中断,与包括既往实施睡眠政策在内的因素无关。
  • 原文结论认为,使用简单可及工具测量声级和睡眠可促进未来研究,并可能可行地融入临床实践。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs.

DESIGN: A cross-sectional, observational study.

SETTING: Australian and New Zealand ICUs.

PATIENTS: All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015.

INTERVENTIONS: Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight.

MEASUREMENTS AND MAIN RESULTS: The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79-83) versus 77 dB (95% CI, 77-78), mean difference 4 dB (95% CI, 0-2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1-4) and three (interquartile range, 2-5), respectively.

CONCLUSIONS: Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.

来源:Crit Care Med,查看原文。版权归原作者所有。