三种婴儿胸外按压技术的随机比较及血流动力学效应:一项随机模拟人研究
该研究由42名波兰国家急救医疗服务人员参与,每人在婴儿模拟人上随机进行10分钟单人心肺复苏,分别采用传统双拇指(TTHT)、传统双指(TFT)和新型双拇指(nTTT)技术。nTTT组收缩压中位数显著高于TFT和TTHT(82 vs 30 vs 41 mmHg),舒张压和平均动脉压也更高。作者认为nTTT可能更有效,且简单易学,但能否转化为临床结局改善需进一步动物和人体试验。
要点
- 在婴儿模拟人单人心肺复苏中,nTTT组收缩压中位数82 mmHg,显著高于TFT组30 mmHg和TTHT组41 mmHg(p<0.001)。
- nTTT组平均动脉压中位数40 mmHg,高于TFT组22 mmHg和TTHT组26 mmHg,差异均显著(p<0.001)。
- nTTT组舒张压中位数16 mmHg,高于TFT组9 mmHg和TTHT组9.5 mmHg(p<0.001)。
- nTTT组脉压中位数67.5 mmHg,高于TTHT组31.5 mmHg和TFT组24 mmHg,差异均显著。
- 作者认为nTTT操作简单,可广泛教授给专业人员和旁观者,但是否改善结局需进一步动物研究和人体试验。
适用人群与场景
- 来自波兰国家急救医疗服务的42名急救人员,在婴儿模拟人上进行单人CPR。
研究设计与关键结果
- 随机模拟人研究,42名急救人员,每人随机顺序进行三种技术各10分钟单人CPR。
- nTTT组收缩压中位数82 mmHg vs TFT组30 mmHg vs TTHT组41 mmHg;nTTT与TFT、nTTT与TTHT差异p<0.001,TFT与TTHT差异p=0.003。
- nTTT组舒张压中位数16 mmHg vs TFT组9 mmHg(p<0.001)vs TTHT组9.5 mmHg(p<0.001)。
- nTTT组平均动脉压中位数40 mmHg vs TFT组22 mmHg vs TTHT组26 mmHg;nTTT与TFT、nTTT与TTHT、TFT与TTHT差异均p<0.001(原文写作TTEHT,按上下文应为TTHT)。
- nTTT组脉压中位数67.5 mmHg vs TTHT组31.5 mmHg vs TFT组24 mmHg;TFT与TTHT差异p=0.025,TFT与nTTT、TTHT与nTTT差异均p<0.001。
证据类型、等级与局限
- 证据类型:随机模拟人研究。
- 局限:作者指出该技术能否转化为临床结局改善需进一步动物研究和后续人体试验。
对床旁实践的改变
- 作者认为nTTT操作简单,可广泛教授给专业人员和旁观者。
- 作者指出nTTT能否改善临床结局需进一步动物研究和人体试验验证。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: Pediatric cardiac arrest is an uncommon but critical life-threatening event requiring effective cardiopulmonary resuscitation. High-quality cardio-pulmonary resuscitation (CPR) is essential, but is poorly performed, even by highly skilled healthcare providers. The recently described two-thumb chest compression technique (nTTT) consists of the two thumbs directed at the angle of 90° to the chest while having the fingers fist-clenched. This technique might facilitate adequate chest-compression depth, chest-compression rate and rate of full chest-pressure relief.
METHODS: 42 paramedics from the national Emergency Medical Service of Poland performed three single-rescuer CPR sessions for 10 minutes each. Each session was randomly assigned to the conventional two-thumb (TTHT), the conventional two-finger (TFT) or the nTTT. The manikin used for this study was connected with an arterial blood pressure measurement device and blood measurements were documented on a 10-seconds cycle.
RESULTS: The nTTT provided significant higher systolic (82 vs. 30 vs. 41 mmHg). A statistically significant difference was noticed between nTTT and TFT (p<.001), nTTT and TTHT (p<0.001), TFT and TTHT (p=0.003). The median diastolic preassure using nTTT was 16 mmHg compared with 9 mmHg for TFT (p<0.001), and 9.5 mmHg for TTHT (p<0.001). Mean arterial pressure using distinct methods varied and amounted to 40 vs. 22. vs. 26 mmHg (nTTT vs. TFT vs. TTHT, respectively). A statistically significant difference was noticed between nTTT and TFT (p<0.001), nTTT and TTEHT (p<0.001), and TFT and TTHT (p<0.001). The highest median pulse pressure was obtained by the nTTT 67.5 mmHg. Pulse pressure was 31.5 mmHg in the TTHT and 24 mmHg in the TFT. The difference between TFT and TTHT (p=0.025), TFT and nTTT (p<0.001), as well as between TTHT and nTTT (p<0.001) were statistically significant.
CONCLUSIONS: The new nTTT technique generated higher arterial blood pressures compared to established chest compression techniques using an infant manikin model, suggesting a more effective chest compression. Our results have important clinical implications as nTTT was simple to perform and could be widely taught to both healthcare professionals and bystanders. Whether this technique translates to improved outcomes over existing techniques needs further animal studies and subsequent human trials.
参考来源
- Smereka J, Szarpak L, Rodríguez-Núñez A, et al. A randomized comparison of three chest compression techniques and associated hemodynamic effect during infant CPR: A randomized manikin study. Am J Emerg Med. 2017. PMID: 28433454. doi:10.1016/j.ajem.2017.04.024
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。