文献速递心脑血管急症呼吸衰竭与机械通气重症综合管理与镇静镇痛

心脏骤停期间肺栓塞的检测——超声发现应谨慎解读

Detection of Pulmonary Embolism During Cardiac Arrest-Ultrasonographic Findings Should Be Interpreted With Caution.
PubMed 文献 · Crit Care Med · 2017-01-01
一句话结论猪模型显示肺栓塞所致心脏骤停时右心室较缺氧和原发性心律失常更扩张,但所有病因均有扩张,基础聚焦心脏超声培训医师诊断准确性中等。

该研究用24头猪随机分为肺栓塞、缺氧和原发性心律失常三组诱导心脏骤停,复苏7分钟后测量右心室直径。主要终点为第三次心律分析时的右心室直径:肺栓塞组32 mm(95%CI 29-36),显著大于缺氧组23 mm(95%CI 20-27)和原发性心律失常组25 mm(95%CI 22-28),绝对差7-9 mm。但所有组在骤停诱导期间右心室均扩张(p<0.01)。接受基础聚焦心脏超声培训的医师能检测约10 mm的右心室直径差异,敏感性79%(95%CI 64-94),特异性68%(95%CI 56-80)。结论挑战了「CPR期间右心室扩张特别提示肺栓塞」的范式。

要点

  • 猪心脏骤停模型中,第三次心律分析时肺栓塞组右心室直径32 mm(95%CI 29-36),大于缺氧组23 mm(95%CI 20-27)和原发性心律失常组25 mm(95%CI 22-28)。
  • 所有三组在骤停诱导期间右心室均扩张(p<0.01),无论骤停病因如何。
  • 基础聚焦心脏超声培训医师检测约10 mm右心室直径差异的敏感性79%(95%CI 64-94),特异性68%(95%CI 56-80)。
  • 作者结论认为这些发现挑战了CPR期间右心室扩张特别与肺栓塞相关的范式。

适用人群与场景

  • 雌性杂交长白/约克夏/杜洛克猪,体重27-32 kg,麻醉后诱导心脏骤停并复苏7分钟。

研究设计与关键结果

  • 研究类型:动物实验,24头猪随机分为肺栓塞、缺氧和原发性心律失常三组诱导心脏骤停。
  • 主要终点为第三次心律分析时右心室直径:肺栓塞组32 mm(95%CI 29-36)vs 缺氧组23 mm(95%CI 20-27)vs 原发性心律失常组25 mm(95%CI 22-28),肺栓塞组绝对差7-9 mm。
  • 基线时无差异;骤停诱导期间所有组右心室均扩张(p<0.01)。
  • 基础聚焦心脏超声培训医师检测约10 mm右心室直径差异的敏感性79%(95%CI 64-94),特异性68%(95%CI 56-80)。

证据类型、等级与局限

  • 证据类型:动物实验(猪模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为CPR期间右心室扩张在所有骤停病因中均可见,基础聚焦心脏超声培训医师诊断准确性中等,这些发现挑战了右心室扩张特别与肺栓塞相关的范式。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to test the hypothesis that the right ventricle is more dilated during resuscitation from cardiac arrest caused by pulmonary embolism, compared with hypoxia and primary arrhythmia.

DESIGN: Twenty-four pigs were anesthetized and cardiac arrest was induced using three different methods. Pigs were resuscitated after 7 minutes of untreated cardiac arrest. Ultrasonographic images were obtained and the right ventricular diameter was measured.

SETTING: University hospital animal laboratory.

SUBJECTS: Female crossbred Landrace/Yorkshire/Duroc pigs (27-32 kg).

INTERVENTIONS: Pigs were randomly assigned to cardiac arrest induced by pulmonary embolism, hypoxia, or primary arrhythmia.

MEASUREMENTS AND MAIN RESULTS: There was no difference at baseline. During induction of cardiac arrest, the right ventricle dilated in all groups (p < 0.01 for all). The primary endpoint was right ventricle diameter at the third rhythm analysis: 32 mm (95% CI, 29-36) for pulmonary embolism which was significantly larger than both hypoxia: 23 mm (95% CI, 20-27) and primary arrhythmia: 25 mm (95% CI, 22-28)-the absolute difference was 7-9 mm. Physicians with basic training in focused cardiac ultrasonography were able to detect a difference in right ventricle diameter of approximately 10 mm with a sensitivity of 79% (95% CI, 64-94) and a specificity of 68% (95% CI, 56-80).

CONCLUSIONS: The right ventricle was more dilated during resuscitation when cardiac arrest was caused by pulmonary embolism compared with hypoxia and primary arrhythmia. However, the right ventricle was dilated, irrespective of the cause of arrest, and diagnostic accuracy by physicians with basic training in focused cardiac ultrasonography was modest. These findings challenge the paradigm that right ventricular dilatation on ultrasound during cardiopulmonary resuscitation is particularly associated with pulmonary embolism.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Aagaard R, Caap P, Hansson NC, et al. Detection of Pulmonary Embolism During Cardiac Arrest-Ultrasonographic Findings Should Be Interpreted With Caution. Crit Care Med. 2017. PMID: 28403120. doi:10.1097/CCM.0000000000002334

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。