文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

探索感染性休克患者液体反应性的最佳预测指标

Exploring the best predictors of fluid responsiveness in patients with septic shock.
PubMed 文献 · Am J Emerg Med · 2017-03-22
一句话结论机械通气感染性休克患者中,颈动脉峰值流速呼吸变异率(ΔCDPV)预测液体反应性最佳,阈值13%时敏感度78%、特异度90%。

本研究为前瞻性观察性研究,纳入机械通气感染性休克患者,评估颈动脉与肱动脉峰值流速呼吸变异及其他血流动力学参数对液体反应性的预测价值。所有患者接受200 mL生理盐水负荷,反应者27例、无反应者22例;反应者SVV、PVI、ΔIVC、ΔCDPV、ΔVpeak brach均更高,且均与心脏指数变化呈显著线性相关。以ΔCI≥10%定义反应者时,ΔCDPV阈值13%的敏感度78%、特异度90%,优于SVV、PVI、ΔIVC和ΔVpeak brach。作者认为超声评估ΔIVC和ΔVpeak brach、尤其是ΔCDPV可预测液体反应性,可能推荐作为机械通气感染性休克患者连续无创监测功能性血流动力学参数的方法。

要点

  • 以ΔCI≥10%定义液体反应者时,ΔCDPV阈值13%预测液体反应性的敏感度78%、特异度90%,为所评估指标中最佳。
  • ΔVpeak brach阈值11.7%预测液体反应性的敏感度70%、特异度80%,ΔIVC阈值20.5%的敏感度67%、特异度77%。
  • SVV阈值11.5%预测液体反应性的敏感度75%、特异度85%,PVI阈值15.5%的敏感度65%、特异度80%。
  • 反应者(27例)的SVV、PVI、ΔIVC、ΔCDPV、ΔVpeak brach测量值均高于无反应者(22例),且均与CI变化呈显著线性相关。
  • 作者认为超声评估ΔIVC和ΔVpeak brach、尤其是ΔCDPV可预测液体反应性,可能推荐作为机械通气感染性休克患者连续无创监测功能性血流动力学参数的方法。

适用人群与场景

  • 机械通气下的感染性休克患者,前瞻性观察性研究人群。

诊断标准与关键阈值

  • 以ΔCI≥10%定义液体反应者。
  • 液体负荷为200 mL生理盐水。

处置流程与药物剂量

  • 所有患者接受200 mL生理盐水负荷。
  • 测量中心静脉压、胸腔内血容量指数、每搏量变异度(SVV)、灌注变异指数(PVI),以及超声评估下腔静脉直径呼吸变异率(ΔIVC)、颈动脉多普勒峰值流速呼吸变异率(ΔCDPV)、肱动脉峰值流速呼吸变异率(ΔVpeak brach)。

研究设计与关键结果

  • 前瞻性观察性研究,纳入机械通气感染性休克患者,反应者27例、无反应者22例。
  • 反应者SVV、PVI、ΔIVC、ΔCDPV、ΔVpeak brach测量值均高于无反应者,且均与CI变化呈显著线性相关。
  • 以ΔCI≥10%定义反应者,ROC曲线分析显示SVV阈值11.5%预测液体反应性的敏感度75%、特异度85%。
  • PVI阈值15.5%预测液体反应性的敏感度65%、特异度80%。
  • ΔIVC阈值20.5%预测液体反应性的敏感度67%、特异度77%。
  • ΔCDPV阈值13%预测液体反应性的敏感度78%、特异度90%。
  • ΔVpeak brach阈值11.7%预测液体反应性的敏感度70%、特异度80%。

证据类型、等级与局限

  • 证据类型:前瞻性观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为超声评估ΔIVC和ΔVpeak brach、尤其是ΔCDPV可预测液体反应性,可能推荐作为机械通气感染性休克患者连续无创监测功能性血流动力学参数的方法。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate respiratory variations in carotid and brachial peak velocity and other hemodynamic parameters to predict responsiveness to fluid challenge.

METHODS: A prospective observational study was performed on mechanically ventilated patients with septic shock. Outcomes included the measurements of central venous pressure, intrathoracic blood volume index, stroke volume variation (SVV), pleth variability index(PVI), and ultrasound assessments of respiratory variations in inferior vena cava diameter (ΔIVC), carotid Doppler peak velocity (ΔCDPV), and brachial artery peak velocity (ΔVpeak brach).

RESULTS: All patients received 200 mL normal saline challenge. There were 27 responders and 22 non-responders. Responders had higher SVV, PVI, ΔIVC, ΔCDPV, and ΔVpeak brach measurements. In addition, all these measurements had statistically significant linear correlations with changes in cardiac index (CI).When responders were defined by ΔCI≥10%, receiver operating characteristics (ROC) curve analysis showed that fluid responsiveness could be predicted:11.5% optimal cut-off 1evels of SVV with sensitivity of 75% and specificity of 85%, 15.5% optimal cut-off 1evels of PVI with sensitivity of 65% and specificity of 80%, 20.5% optimal cut-off 1evels of ΔIVC with sensitivity of 67% and specificity of 77%, 13% optimal cut-off 1evels of ΔCDPV with sensitivity of 78%% and specificity of 90%, 11.7% optimal cut-off 1evels of ΔVpeak brach with sensitivity of 70% and specificity of 80%.

CONCLUSION: Ultrasound assessment of ΔIVC and ΔVpeak brach, especially ΔCDPV, could predict fluid responsiveness and might be recommended as a continuous and noninvasive method to monitor functional hemodynamic parameter in mechanically ventilated patients with septic shock.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Lu N, Xi X, Jiang L, et al. Exploring the best predictors of fluid responsiveness in patients with septic shock. Am J Emerg Med. 2017. PMID: 28363617. doi:10.1016/j.ajem.2017.03.052

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。