文献速递心脑血管急症重症综合管理与镇静镇痛

脑电图预测心脏骤停后的不良与良好结局:一项双中心研究

Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study.
PubMed 文献 · Crit Care Med · 2017-01-01
一句话结论心脏骤停后目标温度管理期间及之后,脑电图反应性预测不良与良好结局,运动反应预测良好结局(III级证据)。

该双中心队列研究纳入2009年4月至2016年3月连续收治的357例心脏骤停后昏迷成人,均接受目标温度管理及标准化临床、神经生理(含目标温度管理期间及之后的脑电图)和生化评估。早期脑电图反应性和连续性、屈肌或更好运动反应对良好结局(CPC 1-2)的阳性预测值均大于70%,反应性(80.4%,95%CI 75.9-84.4%)和运动反应(80.1%,95%CI 75.6-84.1%)准确率最高。早期良性脑电图预示良好结局的比例为86.2%(95%CI 79.8-91.1%)。早期癫痫样或非反应性、晚期非反应性脑电图、体感诱发电位消失、瞳孔或角膜反射消失、肌阵挛、神经元特异性烯醇化酶大于75 µg/L对死亡预测的假阳性率均小于5%,其中早期脑电图反应性准确率最高(86.6%,95%CI 82.6-90.0%)。早期高度恶性脑电图假阳性率1.5%,准确率85.7%(95%CI 81.7-89.2%)。

要点

  • 心脏骤停后昏迷成人中,早期脑电图反应性对良好结局(CPC 1-2)的准确率为80.4%(95%CI 75.9-84.4%),对死亡预测准确率86.6%(95%CI 82.6-90.0%)。
  • 早期脑电图良性模式预示良好结局的比例为86.2%(95%CI 79.8-91.1%)。
  • 早期高度恶性脑电图预测死亡的假阳性率仅1.5%,准确率85.7%(95%CI 81.7-89.2%)。
  • 早期癫痫样或非反应性脑电图、晚期非反应性脑电图、体感诱发电位消失、瞳孔或角膜反射消失、肌阵挛、神经元特异性烯醇化酶大于75 µg/L预测死亡的假阳性率均小于5%。
  • 早期脑电图反应性和连续性、屈肌或更好运动反应对良好结局的阳性预测值均大于70%。

适用人群与场景

  • 心脏骤停后连续收治的昏迷成人,来自两个学术医院(瑞士洛桑大学医院;美国明尼苏达州罗切斯特梅奥诊所),通过前瞻性登记识别。
  • 所有患者均接受目标温度管理,并接受预设的标准化临床、神经生理(特别是目标温度管理期间及之后的脑电图)和生化评估。

诊断标准与关键阈值

  • 良好结局定义为3个月时脑功能分类(Cerebral Performance Categories)1和2。
  • 脑电图变量包括反应性、连续性、癫痫样特征,以及基于美国临床神经生理学会命名预设的「良性」或「高度恶性」模式。
  • 其他预测指标包括体感诱发电位、瞳孔或角膜反射、肌阵挛、神经元特异性烯醇化酶。

红旗征与不能漏的情况

  • 早期癫痫样或非反应性脑电图、晚期非反应性脑电图、体感诱发电位消失、瞳孔或角膜反射消失、肌阵挛、神经元特异性烯醇化酶大于75 µg/L对死亡预测的假阳性率均小于5%。
  • 早期高度恶性脑电图对死亡预测的假阳性率为1.5%。

研究设计与关键结果

  • 研究类型为队列研究(2009年4月至2016年3月),在两个学术医院进行,纳入357例心脏骤停后昏迷成人。
  • 早期脑电图反应性对良好结局的准确率为80.4%(95%CI 75.9-84.4%),运动反应为80.1%(95%CI 75.6-84.1%)。
  • 早期良性脑电图预示良好结局的比例为86.2%(95%CI 79.8-91.1%)。
  • 早期脑电图反应性对死亡预测的准确率最高,为86.6%(95%CI 82.6-90.0%)。
  • 早期高度恶性脑电图预测死亡的假阳性率为1.5%,准确率为85.7%(95%CI 81.7-89.2%)。

证据类型、等级与局限

  • 研究提供III级证据,表明脑电图反应性预测心脏骤停后的不良与良好结局,运动反应预测良好结局。
  • 脑电图反应性似乎是区分良好与不良结局的最佳指标。
  • 标准化脑电图判读似乎可预测目标温度管理期间及之后的两种结局。
  • 局限:原文未报告局限性

对床旁实践的改变

  • 作者认为,脑电图反应性似乎是区分心脏骤停后良好与不良结局的最佳指标。
  • 作者认为,标准化脑电图判读似乎可预测目标温度管理期间及之后的良好与不良结局。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: The prognostic role of electroencephalography during and after targeted temperature management in postcardiac arrest patients, relatively to other predictors, is incompletely known. We assessed performances of electroencephalography during and after targeted temperature management toward good and poor outcomes, along with other recognized predictors.

DESIGN: Cohort study (April 2009 to March 2016).

SETTING: Two academic hospitals (Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland; Mayo Clinic, Rochester, MN).

PATIENTS: Consecutive comatose adults admitted after cardiac arrest, identified through prospective registries.

INTERVENTIONS: All patients were managed with targeted temperature management, receiving prespecified standardized clinical, neurophysiologic (particularly, electroencephalography during and after targeted temperature management), and biochemical evaluations.

MEASUREMENTS AND MAIN RESULTS: We assessed electroencephalography variables (reactivity, continuity, epileptiform features, and prespecified "benign" or "highly malignant" patterns based on the American Clinical Neurophysiology Society nomenclature) and other clinical, neurophysiologic (somatosensory-evoked potential), and biochemical prognosticators. Good outcome (Cerebral Performance Categories 1 and 2) and mortality predictions at 3 months were calculated. Among 357 patients, early electroencephalography reactivity and continuity and flexor or better motor reaction had greater than 70% positive predictive value for good outcome; reactivity (80.4%; 95% CI, 75.9-84.4%) and motor response (80.1%; 95% CI, 75.6-84.1%) had highest accuracy. Early benign electroencephalography heralded good outcome in 86.2% (95% CI, 79.8-91.1%). False positive rates for mortality were less than 5% for epileptiform or nonreactive early electroencephalography, nonreactive late electroencephalography, absent somatosensory-evoked potential, absent pupillary or corneal reflexes, presence of myoclonus, and neuron-specific enolase greater than 75 µg/L; accuracy was highest for early electroencephalography reactivity (86.6%; 95% CI, 82.6-90.0). Early highly malignant electroencephalography had an false positive rate of 1.5% with accuracy of 85.7% (95% CI, 81.7-89.2%).

CONCLUSIONS: This study provides class III evidence that electroencephalography reactivity predicts both poor and good outcomes, and motor reaction good outcome after cardiac arrest. Electroencephalography reactivity seems to be the best discriminator between good and poor outcomes. Standardized electroencephalography interpretation seems to predict both conditions during and after targeted temperature management.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Rossetti AO, Tovar Quiroga DF, Juan E, et al. Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study. Crit Care Med. 2017. PMID: 28406812. doi:10.1097/CCM.0000000000002337

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。