指南与共识重症综合管理与镇静镇痛

改良早期预警评分联动SBAR沟通工具的验证:一项混合方法研究

Validation of a modified early warning score-linked Situation-Background-Assessment-Recommendation communication tool: A mixed methods study.
指南 / 共识 · J Clin Nurs · 2017-06-20
一句话结论在南非开普敦医院开发的改良早期预警评分联动SBAR沟通工具经认知访谈、内容验证和评分者间信度测试后,保留45个条目,整体一致率82%,护士可用其按逻辑顺序向医生报告病情恶化信息。

本研究旨在开发并验证一种改良的病情-背景-评估-建议(SBAR)沟通工具,该工具整合了开普敦改良早期预警评分生命体征图表的组成部分,用于报告临床恶化的早期迹象。研究采用序贯三阶段混合方法:认知访谈、内容验证和评分者间信度测试,参与者为开普敦政府医院中目的性选取的专家护士和医生。认知访谈中5名专家促使15/42(35.71%)个条目被修改;18名专家对修订工具的内容验证高(预定≥70%),4/49(8.2%)个条目被修改;两名护士的评分者间信度测试显示37/45(82%)个条目达到高度至完全一致(Cohen's kappa .61-1),一个条目仅轻微一致(Cohen's kappa .20),提示临床判断存在差异。最终验证工具保留45个条目。结论认为这是南非开发的首个改良早期预警评分联动SBAR沟通工具,在当地情境下有效且可靠;护士可使用该验证工具向医生提供病情恶化患者的相关信息,以预防严重不良事件。

要点

  • 最终验证的改良早期预警评分联动SBAR沟通工具保留45个条目,整体一致率82%。
  • 两名护士评分者间信度测试中,37/45(82%)个条目达到高度至完全一致(Cohen's kappa .61-1)。
  • 一个条目仅达到轻微一致(Cohen's kappa .20),提示临床判断存在差异。
  • 认知访谈中5名专家促使15/42(35.71%)个条目被修改;内容验证中18名专家(预定≥70%)使4/49(8.2%)个条目被修改。
  • 护士可使用该验证工具按逻辑顺序向医生提供病情恶化患者的相关信息,以预防严重不良事件。

适用人群与场景

  • 开普敦政府医院中目的性选取的专家护士和医生。

研究设计与关键结果

  • 研究设计为混合方法工具开发与验证,采用序贯三阶段:认知访谈、内容验证和评分者间信度测试。
  • 认知访谈阶段5名专家促使15/42(35.71%)个条目被修改。
  • 内容验证阶段18名专家对修订工具的内容验证高(预定≥70%),4/49(8.2%)个条目被修改。
  • 评分者间信度测试由两名护士完成,37/45(82%)个条目达到高度至完全一致(Cohen's kappa .61-1)。
  • 一个条目达到轻微一致(Cohen's kappa .20),提示临床判断存在差异。
  • 最终验证工具保留45个条目,整体一致率82%。

证据类型、等级与局限

  • 证据类型:混合方法工具开发与验证研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 护士可使用该验证工具向医生提供病情恶化患者的相关信息,按逻辑顺序报告以预防严重不良事件。
  • 作者认为,研究结果为其他非洲国家开发和验证用于报告临床恶化早期迹象的沟通工具提供了参考。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIMS AND OBJECTIVES: To develop and validate a modified Situation-Background-Assessment-Recommendation communication tool incorporating components of the Cape Town modified early warning score vital signs chart for reporting early signs of clinical deterioration.

BACKGROUND: Reporting early signs of physiological and clinical deterioration could prevent "failure to rescue" or unexpected intensive care admission, cardiac arrest or death. A structured communication tool incorporating physiological and clinical parameters allows nurses to provide pertinent information about a deteriorating patient in a logical order.

DESIGN: Mixed methods instrument development and validation.

METHODS: We used a sequential three-phase method: cognitive interviews, content validation and inter-rater reliability testing to validate a self-designed communication tool. Participants were purposively selected expert nurses and doctors in government sector hospitals in Cape Town.

RESULTS: Cognitive interviews with five experts prompted most changes to the communication tool: 15/42 (35.71%) items were modified. Content validation of a revised tool was high by a predetermined ≥70% of 18 experts: 4/49 (8.2%) items were modified. Inter-rater reliability testing by two nurses indicated substantial to full agreement (Cohen's kappa .61-1) on 37/45 (82%) items. The one item achieving slight agreement (Cohen's kappa .20) indicated a difference in clinical judgement. The high overall percentage agreement (82%) suggests that the modified items are sound. Overall, 45 items remained on the validated tool.

CONCLUSION: The first modified early warning score-linked Situation-Background-Assessment-Recommendation communication tool developed in South Africa was found to be valid and reliable in a local context.

RELEVANCE TO CLINICAL PRACTICE: Nurses in South Africa can use the validated tool to provide doctors with pertinent information about a deteriorating patient in a logical order to prevent a serious adverse event. Our findings provide a reference for other African countries to develop and validate communication tools for reporting early signs of clinical deterioration.

来源:J Clin Nurs,查看原文。版权归原作者所有。

参考来源

  1. Burger D, Jordan S, Kyriacos U, et al. Validation of a modified early warning score-linked Situation-Background-Assessment-Recommendation communication tool: A mixed methods study. J Clin Nurs. 2017. PMID: 28401657. doi:10.1111/jocn.13852

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。