机械通气首日平均气道压与中心静脉压升高提示不良结局
该回顾性研究纳入北京协和医院重症医学科2208例机械通气患者,收集首24小时呼吸与血流动力学数据。非幸存者组(177/2208)心率、呼吸频率、中心静脉压和乳酸更高,灌注指数和P(v-a)CO2更低;平均气道压、峰气道压、呼气末正压、驱动压和吸气时间/总呼吸时间更高。中心静脉压升高(OR 1.125,95%CI 1.069-1.184,P<0.001)和平均气道压升高(OR 1.125,95%CI 1.069-1.184,P<0.001)与28天死亡率独立相关。基于中心静脉压和平均气道压截断值分组后,三组28天生存率差异显著(log rank 131.931,P<0.001)。
要点
- 机械通气首24小时内中心静脉压升高与28天死亡率独立相关(OR 1.125,95%CI 1.069-1.184,P<0.001)。
- 机械通气首24小时内平均气道压升高与28天死亡率独立相关(OR 1.125,95%CI 1.069-1.184,P<0.001)。
- 非幸存者组(177/2208)中心静脉压、平均气道压、峰气道压、呼气末正压、驱动压均显著高于幸存者(P<0.05)。
- 中心静脉压与平均气道压均高的患者28天生存率显著低于仅一项高或两项均低者(log rank 131.931,P<0.001)。
- 非幸存者组心率、呼吸频率、乳酸更高,灌注指数和P(v-a)CO2更低(P<0.05)。
适用人群与场景
- ICU内接受机械通气的患者,来自北京协和医院重症医学科。
- 回顾性分析机械通气首24小时内的临床数据。
研究设计与关键结果
- 回顾性研究,纳入2208例机械通气患者,非幸存者177例。
- 非幸存者组心率、呼吸频率、中心静脉压、乳酸更高,灌注指数和P(v-a)CO2更低(P<0.05)。
- 非幸存者组平均气道压、峰气道压、呼气末正压、驱动压、吸气时间/总呼吸时间显著更高,动脉氧分压和动态顺应性更低(P<0.05)。
- 中心静脉压升高(OR 1.125,95%CI 1.069-1.184,P<0.001)和平均气道压升高(OR 1.125,95%CI 1.069-1.184,P<0.001)与28天死亡率独立相关。
- 中心静脉压和平均气道压的ROC曲线下面积分别为0.795(95%CI 0.654-0.757)和0.833(95%CI 0.608-0.699)。
- 按中心静脉压和平均气道压截断值分为三组:两者均低、仅一项高、两者均高,三组28天生存率差异显著(log rank 131.931,P<0.001)。
证据类型、等级与局限
- 证据类型:回顾性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,机械通气首24小时内平均气道压和中心静脉压升高的患者结局更差。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: The relationship between respiratory mechanical parameters and hemodynamic variables remains unclear. This study was performed to determine whether mean airway pressure and central venous pressure in the first day of mechanical ventilation are associated with patient outcomes.
DESIGN: Retrospective first 24-hour comparison during ICU stay.
SETTING: The Department of Critical Care Medicine of Peking Union Medical College Hospital.
PATIENTS: Patients with mechanical ventilation.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: The clinical data of patients who received mechanical ventilation, especially respiratory and hemodynamic data, were collected and analyzed. In terms of the hemodynamic and perfusion data, the nonsurvivors group (177/2,208) had higher heart rate, respiratory rate, central venous pressure, and lactates and a lower perfusion index and P(v-a)CO2 (p < 0.05). In terms of respiratory condition, mean airway pressure, peak airway pressure, positive end-expiratory pressure, driving pressure, and inspiratory time/total respiration time of nonsurvivors were significantly higher, and arterial oxygen pressure and dynamic compliance worsened and were lower than the survivors (p < 0.05). Increased central venous pressure (odds ratio, 1.125; 95% CI, 1.069-1.184; p < 0.001) and elevated mean airway pressure (odds ratio, 1.125; 95% CI, 1.069-1.184; p < 0.001) were independently associated with 28-day mortality. The area under receiver operating characteristic demonstrated that central venous pressure and mean airway pressure were measured at 0.795 (95% CI, 0.654-0.757) and 0.833 (95% CI, 0.608-0.699), respectively. Based on the cutoff of central venous pressure and mean airway pressure, all of the participants were divided into the following groups: low central venous pressure and mean airway pressure, only high central venous pressure or mean airway pressure, or high central venous pressure and mean airway pressure. Post hoc tests showed significant differences among these three groups based on 28-day survival (log rank [Mantel-Cox], 131.931; p < 0.001).
CONCLUSIONS: During the first 24 hours of mechanical ventilation, patients with elevated mean airway pressure and elevated central venous pressure had worse outcomes.
参考来源
- Long Y, Su L, Zhang Q, et al. Elevated Mean Airway Pressure and Central Venous Pressure in the First Day of Mechanical Ventilation Indicated Poor Outcome. Crit Care Med. 2017. PMID: 28244940. doi:10.1097/CCM.0000000000002290
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。