急诊科启动肺保护性通气(LOV-ED):一项准实验前后对照试验
该研究为前后对照的准实验设计,纳入干预前组1192例和干预组513例,干预为急诊科多层面机械通气方案,目标包括肺保护性潮气量、合适设置呼气末正压、快速脱氧和床头抬高。倾向性评分匹配分析(每组490例)显示,主要复合终点(急性呼吸窘迫综合征和呼吸机相关并发症)在干预前组71例(14.5%)vs 干预组36例(7.4%),校正OR 0.47(95%CI 0.31-0.71)。干预还与无呼吸机天数(均差3.7;95%CI 2.3-5.1)、无ICU天数(均差2.4;95%CI 1.0-3.7)和无住院天数(均差2.4;95%CI 1.2-3.6)增加相关。死亡率干预前组34.1% vs 干预组19.6%(校正OR 0.47;95%CI 0.35-0.63)。作者认为在急诊科实施机械通气方案可行,并与安全机械通气实施和临床结局的显著改善相关。
要点
- 急诊科实施多层面肺保护性通气方案后,肺保护性通气实施率增加48.4%。
- 倾向性评分匹配(每组490例)主要复合终点(ARDS和呼吸机相关并发症)干预前组14.5% vs 干预组7.4%,校正OR 0.47(95%CI 0.31-0.71)。
- 干预与无呼吸机天数增加相关(均差3.7;95%CI 2.3-5.1)。
- 干预与无ICU天数增加相关(均差2.4;95%CI 1.0-3.7)和无住院天数增加相关(均差2.4;95%CI 1.2-3.6)。
- 死亡率干预前组34.1% vs 干预组19.6%(校正OR 0.47;95%CI 0.35-0.63)。
适用人群与场景
- 急诊科接受机械通气的患者,干预前组1192例,干预组513例。
处置流程与药物剂量
- 干预为急诊科多层面机械通气方案,目标包括肺保护性潮气量、合适设置呼气末正压、快速脱氧和床头抬高。
研究设计与关键结果
- 研究类型为准实验前后对照研究,包括干预前阶段、约6个月导入期和前瞻性干预阶段。
- 主要终点为急性呼吸窘迫综合征和呼吸机相关并发症的复合发生率,倾向性评分匹配分析(每组490例)显示干预前组71例(14.5%)vs 干预组36例(7.4%),校正OR 0.47(95%CI 0.31-0.71)。
- 肺保护性通气在干预组增加48.4%。
- 无呼吸机天数均差3.7(95%CI 2.3-5.1),无ICU天数均差2.4(95%CI 1.0-3.7),无住院天数均差2.4(95%CI 1.2-3.6),均与干预相关。
- 死亡率干预前组34.1% vs 干预组19.6%(校正OR 0.47;95%CI 0.35-0.63)。
证据类型、等级与局限
- 证据类型:准实验前后对照研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为在急诊科实施机械通气方案可行,并与安全机械通气实施和临床结局的显著改善相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
STUDY OBJECTIVE: We evaluated the efficacy of an emergency department (ED)-based lung-protective mechanical ventilation protocol for the prevention of pulmonary complications.
METHODS: This was a quasi-experimental, before-after study that consisted of a preintervention period, a run-in period of approximately 6 months, and a prospective intervention period. The intervention was a multifaceted ED-based mechanical ventilator protocol targeting lung-protective tidal volume, appropriate setting of positive end-expiratory pressure, rapid oxygen weaning, and head-of-bed elevation. A propensity score-matched analysis was used to evaluate the primary outcome, which was the composite incidence of acute respiratory distress syndrome and ventilator-associated conditions.
RESULTS: A total of 1,192 patients in the preintervention group and 513 patients in the intervention group were included. Lung-protective ventilation increased by 48.4% in the intervention group. In the propensity score-matched analysis (n=490 in each group), the primary outcome occurred in 71 patients (14.5%) in the preintervention group compared with 36 patients (7.4%) in the intervention group (adjusted odds ratio 0.47; 95% confidence interval [CI] 0.31 to 0.71). There was an increase in ventilator-free days (mean difference 3.7; 95% CI 2.3 to 5.1), ICU-free days (mean difference 2.4; 95% CI 1.0 to 3.7), and hospital-free days (mean difference 2.4; 95% CI 1.2 to 3.6) associated with the intervention. The mortality rate was 34.1% in the preintervention group and 19.6% in the intervention group (adjusted odds ratio 0.47; 95% CI 0.35 to 0.63).
CONCLUSION: Implementing a mechanical ventilator protocol in the ED is feasible and is associated with significant improvements in the delivery of safe mechanical ventilation and clinical outcome.
参考来源
- Fuller BM, Ferguson IT, Mohr NM, et al. Lung-Protective Ventilation Initiated in the Emergency Department (LOV-ED): A Quasi-Experimental, Before-After Trial. Ann Emerg Med. 2017. PMID: 28259481. doi:10.1016/j.annemergmed.2017.01.013
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。