文献速递复苏、休克与脓毒症创伤与烧伤重症综合管理与镇静镇痛

自动可变主动脉控制与完全主动脉阻断在猪失血模型中的比较

Automated variable aortic control versus complete aortic occlusion in a swine model of hemorrhage.
PubMed 文献 · J Trauma Acute Care Surg · 2017-01-01
一句话结论在致命性肝出血猪模型中,可变主动脉控制(VAC)实现允许性区域低灌注,较完全主动脉阻断(AO)降低缺血负担并提高生存率(90% vs 50%)。

该研究在25头猪中建立致命性非控制性肝出血模型,随机分为对照组(n=5)、完全主动脉阻断组(AO,n=10)和允许性区域低灌注联合可变主动脉控制组(VAC,n=10),治疗90分钟后行损伤控制手术和复苏,重症监护持续4.5小时或至死亡。VAC组在主动脉阻断20分钟后启动远端动态血流,根据预设近端平均动脉压范围调节远端流量在100–300 mL/min。结果显示VAC组生存率90%,AO组50%,对照组0%(p<0.01);VAC组近端MAP更接近生理且肾血流更高,重症监护期间近端MAP、颈动脉及肾血流、乳酸清除率和尿量均优于AO,且维持近端MAP≥50 mm Hg所需晶体液量仅为AO组一半。

要点

  • 在致命性肝出血猪模型中,VAC组生存率90%(9/10),AO组50%(5/10),对照组0%(0/5),p<0.01。
  • VAC组在AO 20分钟后启动远端动态血流,流量调节在100–300 mL/min,基于预设近端MAP范围。
  • 干预期间VAC组近端MAP为84±18 mm Hg,低于AO组的105±9 mm Hg(p<0.01),肾血流高于AO组(p=0.02)。
  • 重症监护期间VAC组近端MAP 73±8 mm Hg vs AO组50±6 mm Hg(p<0.01),颈动脉和肾血流、乳酸清除率、尿量均高于AO组(p<0.01)。
  • VAC组维持近端MAP≥50 mm Hg所需晶体液量为AO组的一半(p<0.01)。

适用人群与场景

  • 致命性非控制性肝出血的猪模型,体重未报告;动物随机接受90分钟治疗。
  • 研究场景为动物实验,非人类急诊或ICU。

诊断标准与关键阈值

  • 预设近端平均动脉压(MAP)范围用于调节VAC组远端流量(100–300 mL/min),具体数值原文未报告。
  • 重症监护期间以近端MAP≥50 mm Hg为目标进行晶体液复苏。

处置流程与药物剂量

  • VAC组:先完全阻断主动脉20分钟,然后启动动态远端血流,根据预设近端MAP范围调节流量在100–300 mL/min。
  • 90分钟干预后行损伤控制手术、复苏并恢复全血流。
  • 重症监护期间维持近端MAP≥50 mm Hg,VAC组所需晶体液量为AO组一半。

研究设计与关键结果

  • 研究类型:动物实验(猪),25头,随机分为对照组(n=5)、AO组(n=10)、VAC组(n=10)。
  • 主要生存率:对照组0%,AO组50%,VAC组90%(p<0.01)。
  • 干预期间:VAC组近端MAP 84±18 mm Hg vs AO组105±9 mm Hg(p<0.01);VAC组肾血流高于AO组(p=0.02)。
  • 重症监护期间:VAC组近端MAP 73±8 mm Hg vs AO组50±6 mm Hg(p<0.01);VAC组颈动脉和肾血流、乳酸清除率、尿量均高于AO组(p<0.01);VAC组维持近端MAP≥50 mm Hg所需晶体液量为AO组一半(p<0.01)。

证据类型、等级与局限

  • 证据类型:动物实验(猪模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,允许性区域低灌注联合可变主动脉控制可减轻远端缺血的不良效应,优化脑和心脏的近端压力,并在此致命性出血模型中防止失血致死。
  • 这些发现为继续开发该新范式提供基础知识,并为下一代血管内装置设计提供参考。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Future endovascular hemorrhage control devices will require features that mitigate the adverse effects of vessel occlusion. Permissive regional hypoperfusion (PRH) with variable aortic control (VAC) is a novel strategy to minimize hemorrhage and reduce the ischemic burden of complete aortic occlusion (AO). The objective of this study was to compare PRH with VAC to AO in a lethal model of hemorrhage.

METHODS: Twenty-five swine underwent cannulation of the supraceliac aorta, with diversion of aortic flow through an automated extracorporeal circuit. After creation of uncontrolled liver hemorrhage, animals were randomized to 90 minutes of treatment: Control (full, unregulated flow; n = 5), AO (no flow; n = 10), and PRH with VAC (dynamic distal flow initiated after 20 minutes of AO; n = 10). In the PRH group, distal flow rates were regulated between 100 and 300 mL/min based on a desired, preset range of proximal mean arterial pressure (MAP). At 90 minutes, damage control surgery, resuscitation, and restoration of full flow ensued. Critical care continued for 4.5 hours or until death. Hemodynamic parameters and markers of ischemia were recorded.

RESULTS: Study survival was 0%, 50%, and 90% for control, AO, and VAC, respectively (p < 0.01). During intervention, VAC resulted in more physiologic proximal MAP (84 ± 18 mm Hg vs. 105 ± 9 mm Hg, p < 0.01) and higher renal blood flow than AO animals (p = 0.02). During critical care, VAC resulted in higher proximal MAP (73 ± 8 mm Hg vs. 50 ± 6 mm Hg, p < 0.01), carotid and renal blood flow (p < 0.01), lactate clearance (p < 0.01), and urine output (p < 0.01) than AO despite requiring half the volume of crystalloids to maintain proximal MAP ≥50 mm Hg (p < 0.01).

CONCLUSION: Permissive regional hypoperfusion with variable aortic control minimizes the adverse effects of distal ischemia, optimizes proximal pressure to the brain and heart, and prevents exsanguination in this model of lethal hemorrhage. These findings provide foundational knowledge for the continued development of this novel paradigm and inform next-generation endovascular designs.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Williams TK, Neff LP, Johnson MA, et al. Automated variable aortic control versus complete aortic occlusion in a swine model of hemorrhage. J Trauma Acute Care Surg. 2017. PMID: 28166165. doi:10.1097/TA.0000000000001372

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。