文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

急性呼吸窘迫综合征五十年研究:急性呼吸窘迫综合征的呼气末正压设定

Fifty Years of Research in ARDS. Setting Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome.
PubMed 文献 · Am J Respir Crit Care Med · 2017-01-01
一句话结论尚无单一呼气末正压滴定方法被证实优于其他方法;未来试验应聚焦识别高呼气末正压复张反应者及临床重要结局(如死亡率)。

该综述回顾了自急性呼吸窘迫综合征首次描述以来呼气末正压(PEEP)在机械通气中的应用及多种优化滴定策略。较高PEEP可改善动脉氧合、降低潮气性肺应力与应变、防止呼气末肺泡塌陷从而促进更均匀通气,但也可能导致循环抑制并通过肺泡过度膨胀参与呼吸机相关性肺损伤。PEEP的总体效应主要取决于被复张参与通气的肺泡数量与PEEP应用时过度膨胀的肺量之间的平衡。评估PEEP肺复张的技术可能有助于指导更安全有效的PEEP滴定;部分策略试图权衡氧合改善与防止周期性肺泡塌陷的益处及过度膨胀的潜在危害。一种方法是优先支持动脉氧合的PEEP/FiO2表,其他方法基于平台压、呼吸系统顺应性或跨肺压等机械参数设定PEEP;尚无单一PEEP滴定方法被证实较其他方法改善临床结局。

要点

  • 较高PEEP可改善动脉氧合、降低潮气性肺应力与应变、防止呼气末肺泡塌陷以促进更均匀通气。
  • PEEP也可能导致循环抑制,并通过肺泡过度膨胀参与呼吸机相关性肺损伤。
  • PEEP的总体效应主要取决于被复张参与通气的肺泡数量与PEEP应用时过度膨胀的肺量之间的平衡。
  • 评估PEEP肺复张的技术可能有助于指导更安全有效的PEEP滴定。
  • 尚无单一PEEP滴定方法被证实较其他方法改善临床结局;未来试验应聚焦识别高PEEP复张反应者及临床重要结局(如死亡率)。

适用人群与场景

  • 接受机械通气的急性呼吸窘迫综合征(ARDS)患者。

处置流程与药物剂量

  • 一种PEEP滴定方法是使用PEEP/FiO2表,优先支持动脉氧合。
  • 其他方法基于机械参数设定PEEP,如平台压、呼吸系统顺应性或跨肺压。
  • 评估肺复张的技术可能有助于指导更安全有效的PEEP滴定。
  • 部分PEEP滴定策略试图权衡对动脉氧合和防止周期性肺泡塌陷的有益效应与过度膨胀的潜在危害。

红旗征与不能漏的情况

  • PEEP可能导致循环抑制。
  • PEEP可通过肺泡过度膨胀参与呼吸机相关性肺损伤。

研究设计与关键结果

  • 该综述回顾了自ARDS首次描述以来PEEP在机械通气中的应用及多种优化滴定策略。
  • 较高PEEP可改善动脉氧合、降低潮气性肺应力与应变、防止呼气末肺泡塌陷以促进更均匀通气,但也可能导致循环抑制并通过肺泡过度膨胀参与呼吸机相关性肺损伤。
  • PEEP的总体效应主要取决于被复张参与通气的肺泡数量与PEEP应用时过度膨胀的肺量之间的平衡。
  • 尚无单一PEEP滴定方法被证实较其他方法改善临床结局。
  • 未来试验应聚焦识别高PEEP复张反应者及临床重要结局(如死亡率)。

证据类型、等级与局限

  • 证据类型:综述。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 该综述提示临床医生在设定PEEP时应权衡肺复张获益与过度膨胀及循环抑制风险。
  • 评估肺复张的技术可能有助于指导更安全有效的PEEP滴定。
  • 尚无单一PEEP滴定方法被证实较其他方法改善临床结局。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Positive end-expiratory pressure (PEEP) has been used during mechanical ventilation since the first description of acute respiratory distress syndrome (ARDS). In the subsequent decades, many different strategies for optimally titrating PEEP have been proposed. Higher PEEP can improve arterial oxygenation, reduce tidal lung stress and strain, and promote more homogenous ventilation by preventing alveolar collapse at end expiration. However, PEEP may also cause circulatory depression and contribute to ventilator-induced lung injury through alveolar overdistention. The overall effect of PEEP is primarily related to the balance between the number of alveoli that are recruited to participate in ventilation and the amount of lung that is overdistended when PEEP is applied. Techniques to assess lung recruitment from PEEP may help to direct safer and more effective PEEP titration. Some PEEP titration strategies attempt to weigh beneficial effects on arterial oxygenation and on prevention of cyclic alveolar collapse with the harmful potential of overdistention. One method for PEEP titration is a PEEP/FiO2 table that prioritizes support for arterial oxygenation. Other methods set PEEP based on mechanical parameters, such as the plateau pressure, respiratory system compliance, or transpulmonary pressure. No single method of PEEP titration has been shown to improve clinical outcomes compared with other approaches of setting PEEP. Future trials should focus on identifying individuals who respond to higher PEEP with recruitment and on clinically important outcomes (e.g., mortality).

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Sahetya SK, Goligher EC, Brower RG, et al. Fifty Years of Research in ARDS. Setting Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome. Am J Respir Crit Care Med. 2017. PMID: 28146639. doi:10.1164/rccm.201610-2035CI

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。