公众号 / 文章创伤与烧伤

超声引导锁骨后入路锁骨下臂丛神经阻滞用于上肢急诊操作

Ultrasound-guided retroclavicular approach infraclavicular brachial plexus block for upper extremity emergency procedures.
PubMed 文献 · Am J Emerg Med · 2017-01-15
一句话结论美国麻醉学会指南推荐多模式镇痛联合区域麻醉技术;RAPTIR作为新型锁骨下臂丛阻滞技术,作者认为可能适合急诊上肢操作。

美国麻醉学会指南推荐多模式镇痛,将区域麻醉技术与药物治疗相结合,以改善围操作期疼痛管理并减少阿片类药物相关并发症。上肢常见急诊操作(骨折脱位复位、清创、脓肿切开引流)是超声引导臂丛区域麻醉的理想适应证,但急诊操作者因担心并发症和技术难度而采用有限。RAPTIR是一种新描述的超声引导臂丛阻滞技术,通过优化超声下针的显像使区域麻醉更安全、更易操作;单次显像良好的注射远离颈部与胸部关键结构,可提供广泛上肢麻醉,可能降低膈肌麻痹、中枢阻滞、神经损伤、血管穿刺和气胸等并发症风险,且患者体位适合清醒急性损伤的急诊患者。本文首次描述RAPTIR在急诊科的应用,作者初步经验提示这是急诊环境下臂丛区域麻醉有前景的新技术。

要点

  • 美国麻醉学会指南推荐多模式镇痛,将区域麻醉技术与药物治疗联合,以改善围操作期疼痛管理并减少阿片相关并发症。
  • RAPTIR通过优化超声下针显像,单次注射远离颈部与胸部关键结构,可能降低膈肌麻痹、中枢阻滞、神经损伤、血管穿刺和气胸风险。
  • RAPTIR患者体位为上肢内收于体侧舒适位,适合清醒、急性损伤的急诊患者。
  • 本文首次描述RAPTIR在急诊科的应用,作者初步经验提示这是急诊臂丛区域麻醉有前景的新技术。

适用人群与场景

  • 上肢急诊操作患者,如骨折和脱位复位、伤口清创、脓肿切开引流。
  • 清醒、急性损伤的急诊患者,上肢保持内收于体侧舒适位。

处置流程与药物剂量

  • RAPTIR为超声引导锁骨后入路锁骨下区域臂丛阻滞,采用单次注射,注射位置远离颈部与胸部关键结构,超声下针显像良好。

研究设计与关键结果

  • 本文为首次描述RAPTIR在急诊科应用的病例系列/经验报道,作者初步经验提示这是急诊环境下臂丛区域麻醉有前景的新技术。

证据类型、等级与局限

  • 证据类型:病例系列/经验报道(首次急诊应用描述)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为RAPTIR是急诊环境下臂丛区域麻醉有前景的新技术,可能使区域麻醉更安全、更易操作。
  • 美国麻醉学会指南推荐多模式镇痛,将区域麻醉技术与药物治疗联合,以改善围操作期疼痛管理并减少阿片相关并发症。

指南或共识出处

  • 美国麻醉学会指南

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

The America Society of Anesthesiology guidelines recommend multimodal analgesia that combines regional anesthetic techniques with pharmacotherapy to improve peri-procedural pain management and reduce opioid related complications. Commonly performed emergency procedures of the upper extremity such as fracture and dislocation reduction, wound debridement, and abscess incision and drainage are ideal candidates for ultrasound-guided (USG) regional anesthesia of the brachial plexus. However, adoption of regional anesthesia by emergency practitioners has been limited by concerns for potential complications and perceived technical difficulty. The Retroclavicular Approach to The Infraclavicular Region (RAPTIR) is a newly described USG brachial plexus block technique that optimizes sonographic needle visualization as a means of making regional anesthesia of the upper extremity safer and easier to perform. With RAPTIR a single well-visualized injection distant from key anatomic neck and thorax structures provides extensive upper extremity anesthesia, likely reducing the risk of complications such as diaphragm paralysis, central block, nerve injury, vascular puncture, and pneumothorax. Additionally, patient positioning for RAPTIR is well suited for the awake, acutely injured ED patient as the upper extremity remains adducted in a position of comfort at the patient's side. Thus, RAPTIR is a potentially ideal combination of infraclavicular targeting, excellent needle visualization, single injection, safety, comprehensive upper extremity analgesia, rapid performance, and comfortable patient positioning. Herein we present the first description of the RAPTIR utilized in the ED. Our initial experience suggests this is a promising new technique for brachial plexus regional anesthesia in the ED setting.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Luftig J, Mantuani D, Herring AA, et al. Ultrasound-guided retroclavicular approach infraclavicular brachial plexus block for upper extremity emergency procedures. Am J Emerg Med. 2017. PMID: 28126454. doi:10.1016/j.ajem.2017.01.028

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。