床旁血小板反应性检测(PFA-100®)辅助诊断卒中的效用
该前瞻性研究纳入在城市急诊科就诊的114例疑似急性缺血性卒中症状患者,采血用PFA-100®检测血小板反应性(以闭合时间量化),按出院诊断分为急性缺血性卒中(32例)、短暂性脑缺血发作(33例)和卒中模拟病(49例)。结果显示三组间闭合时间无显著差异,闭合时间不能区分急性缺血性卒中或短暂性脑缺血发作与卒中模拟病。偏头痛史和癫痫史与急性缺血性卒中或短暂性脑缺血发作诊断的较低比值比独立相关(OR 0.31,95%CI 0.10-0.94;OR 0.08,95%CI 0.01-0.88)。作者结论认为闭合时间在急诊不是临床可靠的鉴别指标。
要点
- 114例疑似急性缺血性卒中症状患者中,闭合时间在急性缺血性卒中、短暂性脑缺血发作与卒中模拟病三组间无显著差异。
- PFA-100®闭合时间不能作为急诊区分急性缺血性卒中或短暂性脑缺血发作与卒中模拟病的可靠指标。
- 偏头痛史与急性缺血性卒中或短暂性脑缺血发作诊断的较低比值比独立相关(OR 0.31,95%CI 0.10-0.94)。
- 癫痫史与急性缺血性卒中或短暂性脑缺血发作诊断的较低比值比独立相关(OR 0.08,95%CI 0.01-0.88)。
- 该研究为前瞻性设计,纳入城市急诊科疑似急性缺血性卒中症状患者,样本量114例。
适用人群与场景
- 在城市急诊科就诊的疑似急性缺血性卒中症状患者。
研究设计与关键结果
- 前瞻性研究纳入114例疑似急性缺血性卒中症状患者,出院诊断急性缺血性卒中32例、短暂性脑缺血发作33例、卒中模拟病49例。
- 急性缺血性卒中或短暂性脑缺血发作患者与卒中模拟病患者的闭合时间无显著差异。
- 偏头痛史与急性缺血性卒中或短暂性脑缺血发作诊断的较低比值比独立相关(OR 0.31,95%CI 0.10-0.94)。
- 癫痫史与急性缺血性卒中或短暂性脑缺血发作诊断的较低比值比独立相关(OR 0.08,95%CI 0.01-0.88)。
证据类型、等级与局限
- 证据类型:前瞻性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为闭合时间在急诊不是临床可靠的鉴别急性缺血性卒中、短暂性脑缺血发作与卒中模拟病的指标。
- 偏头痛史和癫痫史与急性缺血性卒中或短暂性脑缺血发作诊断的较低比值比独立相关,可能有助于急诊评估。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Rapid and accurate diagnosis of patients presenting with symptoms of stroke is needed to facilitate the timely delivery of proven effective treatment for patients with acute ischemic stroke (AIS). The aim of this study was to determine whether early assessment of platelet reactivity in patients presenting with symptoms of AIS was associated with a diagnosis of AIS, transient ischemic attack (TIA), or stroke mimic.
METHODS: This prospective study included patients with symptoms of AIS treated at an inner-city emergency department (ED). Blood samples were obtained and assayed for platelet reactivity (quantified by closure time). Patients were grouped by discharge diagnosis into: AIS, TIA, or stroke mimic. Binary logistic regression model was used to predict the association of closure time with the final diagnosis of 1) either AIS or TIA or, 2) stroke mimic.
RESULTS: Of 114 patients enrolled, 32 were diagnosed with AIS, 33 TIA, and 49 were diagnosed as a stroke mimic. There was no significant difference in closure times among patients with a diagnosis of AIS or TIA versus stroke mimic. A history of migraines and history of seizures were independently associated with lower odds of an AIS or TIA diagnosis (OR 0.31, 95% CI 0.10 to 0.94 and OR 0.08, 95% CI 0.01 to 0.88, respectively).
CONCLUSION: Closure time was not found to be a clinically reliable differentiator of patients with a diagnosis of AIS, TIA, or stroke mimic in the ED.
参考来源
- Pearson C, Przyklenk K, Mika VH, et al. Utility of point of care assessment of platelet reactivity (using the PFA-100®) to aid in diagnosis of stroke. Am J Emerg Med. 2016. PMID: 27955971. doi:10.1016/j.ajem.2016.11.036
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。