文献速递复苏、休克与脓毒症消化、代谢与肾脏急症

曼彻斯特分诊系统对急诊脓毒症患者分诊有效性的首次评估

Validity of the Manchester Triage System in patients with sepsis presenting at the ED: a first assessment.
PubMed 文献 · Emerg Med J · 2016-12-19
一句话结论曼彻斯特分诊系统对脓毒症患者的分诊敏感性有限,对脓毒症合并循环功能障碍者敏感性仅61.5%,关键鉴别症状考虑不足。

该回顾性分析纳入2012年6月至2014年3月期间每月前12天就诊于德国波恩某急诊科、年龄>16岁的患者,按1992年美国胸科医师学会与危重症医学会首次共识会议标准将患者分为脓毒症、严重脓毒症、严重脓毒症伴循环功能障碍及无脓毒症四组,评估曼彻斯特分诊系统(MTS)分诊准确性。共评估20836例患者,801例(3.8%)为脓毒症,其中581例(72.5%)为脓毒症、194例(24.2%)为严重脓毒症、26例(3.2%)为严重脓毒症伴循环功能障碍。脓毒症组正确分诊敏感性70.4%(95%CI 66.5-74.0),LR- 0.628(95%CI 0.564-0.698);严重脓毒症组敏感性84.5%(95%CI 78.1-89.4),LR- 0.330(95%CI 0.243-0.450);严重脓毒症伴循环功能障碍组敏感性61.5%(95%CI 39.3-79.8),LR- 0.466(95%CI 0.286-0.757)。作者认为MTS在脓毒症患者优先级判定方面存在弱点,针对识别全身性感染和确认生命体征的目标关键症状(鉴别词)考虑不足。

要点

  • 脓毒症患者经MTS分诊正确优先级的敏感性为70.4%(95%CI 66.5-74.0),LR-为0.628(95%CI 0.564-0.698)。
  • 严重脓毒症患者分诊敏感性为84.5%(95%CI 78.1-89.4),LR-为0.330(95%CI 0.243-0.450)。
  • 严重脓毒症伴循环功能障碍患者分诊敏感性仅61.5%(95%CI 39.3-79.8),LR-为0.466(95%CI 0.286-0.757)。
  • 801例脓毒症患者中,脓毒症581例(72.5%)、严重脓毒症194例(24.2%)、严重脓毒症伴循环功能障碍26例(3.2%)。
  • 作者认为MTS对识别全身性感染和确认生命体征的目标关键症状(鉴别词)考虑不足。

适用人群与场景

  • 年龄>16岁、于2012年6月至2014年3月期间每月前12天就诊于德国波恩某急诊科并使用MTS分诊的患者。

诊断标准与关键阈值

  • 脓毒症分组依据1992年美国胸科医师学会与危重症医学会首次共识会议标准,分为脓毒症、严重脓毒症、严重脓毒症伴循环功能障碍及无脓毒症。

研究设计与关键结果

  • 回顾性分析,共评估20836例患者,801例(3.8%)为脓毒症;其中脓毒症581例(72.5%)、严重脓毒症194例(24.2%)、严重脓毒症伴循环功能障碍26例(3.2%)。
  • 脓毒症组MTS正确分诊敏感性70.4%(95%CI 66.5-74.0),LR- 0.628(95%CI 0.564-0.698)。
  • 严重脓毒症组敏感性84.5%(95%CI 78.1-89.4),LR- 0.330(95%CI 0.243-0.450)。
  • 严重脓毒症伴循环功能障碍组敏感性61.5%(95%CI 39.3-79.8),LR- 0.466(95%CI 0.286-0.757)。

证据类型、等级与局限

  • 证据类型:回顾性分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为MTS在急诊脓毒症患者优先级判定方面存在弱点,针对识别全身性感染和确认生命体征的目标关键症状(鉴别词)考虑不足。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The Manchester Triage System (MTS) does not have a specific presentational flow chart for sepsis. The goal of this investigation was to determine adequacy of acuity assignment for patients with sepsis presenting at the ED and triaged using the MTS.

MATERIALS AND METHODS: This retrospective analysis included patients >16 presenting to an ED in Bonn, Germany, on the first 12 days of each month between June 2012 and March 2014. Patients were classified into one of three septic groups, or no sepsis. For those with sepsis, adequacy of acuity assignment was based on the criteria of the first consensus conference of the American College of Chest Physicians and Society of Critical Care Medicine, first published in 1992. Adequacy of prioritisation is expressed as sensitivity and likelihood ratio (LR-).

RESULTS: Among 20 836 patients evaluated, 801 (3.8%) were septic; of these, 581 (72.5%) had sepsis, 194 (24.2%) had severe sepsis and 26 (3.2%) had severe sepsis with circulation dysfunction. Patients who met the criteria for sepsis were correctly prioritised with a sensitivity of 70.4% (95% CI 66.5 to 74.0). The LR- was 0.628 (95% CI 0.564 to 0.698). Patients with severe sepsis were appropriately prioritised with a sensitivity of 84.5% (95% CI 78.1 to 89.4), and LR- was 0.330 (95% CI 0.243 to 0.450). In the group with severe sepsis and circulation dysfunction, sensitivity of MTS was 61.5% (95% CI 39.3 to 79.8), and LR- was 0.466 (95% CI 0.286 to 0.757).

CONCLUSIONS: The MTS has some weaknesses regarding priority levels in emergency patients with septic illness. Overall, target key symptoms (discriminators) which aim at identifying systemic infection and ascertaining vital parameters are insufficiently considered.

来源:Emerg Med J,查看原文。版权归原作者所有。

参考来源

  1. Gräff I, Goldschmidt B, Glien P, et al. Validity of the Manchester Triage System in patients with sepsis presenting at the ED: a first assessment. Emerg Med J. 2016. PMID: 27993937. doi:10.1136/emermed-2015-205309

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。