在儿科急诊使用Pan Optic iExaminer系统进行非散瞳眼底成像
本研究在儿科急诊纳入18岁及以下、主诉非眼部疾病的儿童,按年龄分层(0–2、2–6、6–18岁),使用Pan Optic iExaminer系统进行双眼非散瞳眼底成像,图像由小儿眼科医师根据清晰度和视野进行分级。2–18岁儿童中91.06%(95%CI 86.01%–96.1%)至少获得一张临床合格图像;0–2岁为16%(95%CI 7%–26%),2–6岁为85%(95%CI 76%–94.15%),6–18岁为9%(95%CI 92%–100%,原文此处数值疑有笔误)。中位总检查时间为3分24秒(四分位距2分27秒至4分49秒)。作者结论认为该系统在儿科急诊尤其2–18岁儿童中可稳定获得眼底图像,2岁以下虽可获得临床合格图像但一致性较低。
要点
- 2–18岁儿童中91.06%(95%CI 86.01%–96.1%)至少获得一张临床合格眼底图像。
- 2–6岁组85%(95%CI 76%–94.15%)至少一张临床合格图像,6–18岁组原文报告为9%(95%CI 92%–100%),原文此处数值疑有笔误。
- 0–2岁组仅16%(95%CI 7%–26%)至少一张临床合格图像,一致性较低。
- 中位总检查时间3分24秒(四分位距2分27秒至4分49秒)。
- 作者结论:该系统在儿科急诊尤其2–18岁儿童中可稳定获得眼底图像。
适用人群与场景
- 18岁及以下因非眼部主诉就诊于儿科急诊的儿童,按年龄分层为0–2岁、2–6岁、6–18岁。
诊断标准与关键阈值
- 临床合格图像定义为可供小儿眼科医师获得视神经完整视野的图像,按清晰度和视野分级。
- 易用性定义为80%患者至少一张图像质量达到临床合格、双眼检查时间15分钟或更短、每只眼尝试3次或更少。
处置流程与药物剂量
- 每名入组患儿使用Pan Optic iExaminer系统进行双眼眼底检查,图像提交小儿眼科医师审阅。
研究设计与关键结果
- 研究类型为在儿科急诊开展的前瞻性研究,纳入18岁及以下非眼部主诉患儿,按年龄分层,使用Pan Optic iExaminer系统行双眼非散瞳眼底成像并由小儿眼科医师分级。
- 2–18岁儿童91.06%(95%CI 86.01%–96.1%)至少获得一张临床合格图像。
- 0–2岁组16%(95%CI 7%–26%)、2–6岁组85%(95%CI 76%–94.15%)、6–18岁组9%(95%CI 92%–100%)至少获得一张临床合格图像;原文6–18岁组数值与2–18岁总体数值矛盾,原文此处表述有矛盾。
- 中位总检查时间3分钟24秒(四分位距2分27秒至4分49秒)。
证据类型、等级与局限
- 证据类型:在儿科急诊开展的前瞻性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,使用Pan Optic iExaminer系统在儿科急诊尤其2–18岁儿童中可稳定获得眼底图像;2岁以下虽可获得临床合格图像但一致性较低。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: The primary objective of this study was to determine the percentage of clinically adequate (CA) fundoscopic images that could be obtained using the Pan Optic iExaminer system to perform nonmydriatic fundoscopic imaging in the pediatric emergency department (ED). Secondary objectives were to identify target age groups in which this technology is best utilized and evaluate the overall ease of use in this setting.
METHODS: Children 18 years of age or less who presented to the pediatric ED with a non-eye-related chief complaint were enrolled and stratified by age group (0-2, 2-6, and 6-18 years). Each enrolled patient underwent a bilateral eye examination using the Pan Optic iExaminer system. Images were submitted for review to a pediatric ophthalmologist and were graded based on clarity and field of view. Ease of use was defined as 80% of patients having at least one image of quality to be considered "clinically adequate" for obtaining a full view of the optic nerve, examination time for both eyes 15 minutes or less, and three attempts or less for each eye.
RESULTS: Overall, 91.06% (95% confidence interval [CI] = 86.01% to 96.1%) of children ages 2-18 years had at least one CA image obtained. A total of 16% (95% CI = 7% to 26%) of children 0-2 years, 85% (95% CI = 76% to 94.15%) of children 2-6 years, and 9% (95% CI = 92% to 100%) of 6-18 years had at least one CA image. The median total examination time was 3 minutes 24 seconds (interquartile range = 2 minutes 27 seconds to 4 minutes 49 seconds).
CONCLUSION: Fundoscopic images were consistently obtained using the Pan Optic iExaminer system in the pediatric ED particularly in children 2-18 years of age. CA images were obtained in children less than 2 years old, but less consistently.
参考来源
- Day LM, Wang SX, Huang CJ, et al. Nonmydriatic Fundoscopic Imaging Using the Pan Optic iExaminer System in the Pediatric Emergency Department. Acad Emerg Med. 2017. PMID: 27801997. doi:10.1111/acem.13128
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。