钝性创伤患者的选择性胸部影像学检查:NEXUS胸部算法
本文综述了3项前瞻性多中心研究在12年间推导并验证的决策工具,用于指导成人钝性创伤患者的胸片和胸部CT使用。NEXUS胸片工具含7项标准,检测临床显著损伤的敏感性为99.0%(95%CI 98.2-99.4%),特异性为13.3%(95%CI 12.6%-14.0%)。NEXUS胸部CT-Major工具含6项标准,检测主要损伤的敏感性为99.2%(95%CI 95.4-100%),特异性为37.9%(95%CI 35.8-40.1%);NEXUS CT-All工具含7项标准,检测主要和次要损伤的敏感性为95.4%(95%CI 93.6-96.9%),特异性为25.5%(95%CI 23.5-27.5%)。本文旨在将三种决策工具整合为一个连贯的总结算法,为成人钝性创伤患者的选择性胸部影像学检查提供实践实施建议。
要点
- NEXUS胸片工具7项标准:年龄>60岁、快速减速机制、胸痛、中毒、精神状态改变、分散注意力的疼痛性损伤、胸壁压痛;检测临床显著损伤敏感性99.0%(95%CI 98.2-99.4%),特异性13.3%(95%CI 12.6%-14.0%)。
- NEXUS胸部CT-Major工具6项标准:胸片异常、分散注意力的损伤、胸壁压痛、胸骨压痛、胸椎压痛、肩胛骨压痛;检测主要损伤敏感性99.2%(95%CI 95.4-100%),特异性37.9%(95%CI 35.8-40.1%)。
- NEXUS CT-All工具7项标准:CT-Major的6项标准加快速减速机制;检测主要和次要损伤敏感性95.4%(95%CI 93.6-96.9%),特异性25.5%(95%CI 23.5-27.5%)。
- 本文目的是将三种决策工具整合为统一的总结算法,为成人钝性创伤患者的选择性胸部影像学检查提供实践实施建议。
适用人群与场景
- 成人钝性创伤患者(原文为 adult blunt trauma patients)
诊断标准与关键阈值
- NEXUS胸片工具标准(7项):年龄>60岁、快速减速机制、胸痛、中毒、精神状态改变、分散注意力的疼痛性损伤、胸壁压痛。
- NEXUS胸部CT-Major工具标准(6项):胸片异常、分散注意力的损伤、胸壁压痛、胸骨压痛、胸椎压痛、肩胛骨压痛。
- NEXUS CT-All工具标准(7项):NEXUS CT-Major的6项标准加快速减速机制。
研究设计与关键结果
- 3项前瞻性多中心研究历时12年推导并验证决策工具,用于指导钝性创伤患者胸片和胸部CT的使用。
- NEXUS胸片工具检测临床显著损伤的敏感性为99.0%(95%CI 98.2-99.4%),特异性为13.3%(95%CI 12.6%-14.0%)。
- NEXUS胸部CT决策工具检测临床主要损伤的敏感性为99.2%(95%CI 95.4-100%)。
- NEXUS胸部CT-Major工具检测主要损伤的特异性为37.9%(95%CI 35.8-40.1%)。
- NEXUS CT-All工具检测主要和次要损伤的敏感性为95.4%(95%CI 93.6-96.9%),特异性为25.5%(95%CI 23.5-27.5%)。
证据类型、等级与局限
- 证据类型:综述,汇总3项前瞻性多中心研究的决策工具推导与验证结果。
- 局限:原文未报告局限性
对床旁实践的改变
- 本文提供将NEXUS胸片、NEXUS胸部CT-Major和NEXUS CT-All三种决策工具整合为统一总结算法的实践实施建议,用于指导成人钝性创伤患者的选择性胸部影像学检查。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Chest imaging plays a prominent role in blunt trauma patient evaluation, but indiscriminate imaging is expensive, may delay care, and unnecessarily exposes patients to potentially harmful ionizing radiation. To improve diagnostic chest imaging utilization, we conducted 3 prospective multicenter studies over 12years to derive and validate decision instruments (DIs) to guide the use of chest x-ray (CXR) and chest computed tomography (CT). The first DI, NEXUS Chest x-ray, consists of seven criteria (Age >60years; rapid deceleration mechanism; chest pain; intoxication; altered mental status; distracting painful injury; and chest wall tenderness) and exhibits a sensitivity of 99.0% (95% confidence interval [CI] 98.2-99.4%) and a specificity of 13.3% (95% CI, 12.6%-14.0%) for detecting clinically significant injuries. We developed two NEXUS Chest CT DIs, which are both highly reliable in detecting clinically major injuries (sensitivity of 99.2%; 95% CI 95.4-100%). Designed primarily to focus on detecting major injuries, the NEXUS Chest CT-Major DI consists of six criteria (abnormal CXR; distracting injury; chest wall tenderness; sternal tenderness; thoracic spine tenderness; and scapular tenderness) and exhibits higher specificity (37.9%; 95% CI 35.8-40.1%). Designed to reliability detect both major and minor injuries (sensitivity 95.4%; 95% CI 93.6-96.9%) with resulting lower specificity (25.5%; 95% CI 23.5-27.5%), the NEXUS CT-All rule consists of seven elements (the six NEXUS CT-Major criteria plus rapid deceleration mechanism). The purpose of this review is to synthesize the three DIs into a novel, cohesive summary algorithm with practical implementation recommendations to guide selective chest imaging in adult blunt trauma patients.
参考来源
- Rodriguez RM, Hendey GW, Mower WR, et al. Selective chest imaging for blunt trauma patients: The national emergency X-ray utilization studies (NEXUS-chest algorithm). Am J Emerg Med. 2016. PMID: 27838036. doi:10.1016/j.ajem.2016.10.066
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。