全身炎症反应综合征、快速序贯器官功能评估与器官功能障碍:来自急诊感染患者前瞻性数据库的见解
该前瞻性研究连续纳入8,871例因疑似感染入急诊的患者,旨在评估SIRS的预后影响、比较SIRS与qSOFA对器官功能障碍的诊断准确性,并比较Sepsis-2与Sepsis-3定义。结果显示SIRS与器官功能障碍风险增加相关(RR 3.5),在无器官功能障碍患者中与死亡率相关(OR 3.2);SIRS与qSOFA对器官功能障碍的判别能力相似(AUC 0.72 vs 0.73),qSOFA特异性96.1%但敏感性仅29.7%。Sepsis-2与Sepsis-3器官功能障碍患者死亡率相似(12.5% vs 11.4%),但29%的Sepsis-3器官功能障碍患者不符合Sepsis-2标准。作者认为放弃SIRS概念似乎为时过早,qSOFA作为床旁筛查方法可能因敏感性差而受限,SOFA评分可能需要重新校准。
要点
- 在8,871例急诊感染患者中,qSOFA≥2对器官功能障碍特异性96.1%,但敏感性仅29.7%,可能限制其作为床旁筛查方法。
- SIRS与器官功能障碍风险增加相关(RR 3.5),在无器官功能障碍患者中与死亡率相关(OR 3.2)。
- SIRS与qSOFA对器官功能障碍的判别能力相似(AUC 0.72 vs 0.73)。
- Sepsis-2与Sepsis-3器官功能障碍患者死亡率相似(12.5% vs 11.4%),但29%的Sepsis-3器官功能障碍患者不符合Sepsis-2标准。
- Sepsis-2器官系统功能障碍数量增加与死亡率升高相关。
适用人群与场景
- 连续纳入的因疑似感染入急诊的成年患者,为期3年前瞻性 enrolled。
诊断标准与关键阈值
- SIRS、qSOFA、SOFA评分按原文定义计算;qSOFA评分≥2为阳性。
- 器官功能障碍定义为SOFA总分增加≥2分。
研究设计与关键结果
- 研究类型为前瞻性队列研究,纳入8,871例急诊疑似感染患者,SIRS存在4,176例(47.1%)。
- SIRS与器官功能障碍风险增加相关(RR 3.5),在无器官功能障碍患者中与死亡率相关(OR 3.2)。
- SIRS与qSOFA对器官功能障碍的判别能力相似(AUC 0.72 vs 0.73)。
- qSOFA对器官功能障碍特异性96.1%,敏感性29.7%。
- Sepsis-2与Sepsis-3器官功能障碍患者死亡率相似(12.5% vs 11.4%),29%的Sepsis-3器官功能障碍患者不符合Sepsis-2标准。
- Sepsis-2器官系统功能障碍数量增加与死亡率升高相关。
证据类型、等级与局限
- 证据类型:前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为放弃SIRS概念似乎为时过早,因SIRS仍与器官功能障碍和死亡率相关。
- qSOFA评分≥2特异性高但敏感性差,可能限制其作为床旁筛查方法。
- 尽管Sepsis-2与Sepsis-3器官功能障碍死亡率相当,Sepsis-2关于器官功能障碍数量和类型能提供更多预后和临床信息。
- 作者认为SOFA评分可能需要重新校准。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: A proposed revision of sepsis definitions has abandoned the systemic inflammatory response syndrome (SIRS), defined organ dysfunction as an increase in total Sequential Organ Function Assessment (SOFA) score of ≥ 2, and conceived "qSOFA" (quick SOFA) as a bedside indicator of organ dysfunction. We aimed to (1) determine the prognostic impact of SIRS, (2) compare the diagnostic accuracy of SIRS and qSOFA for organ dysfunction, and (3) compare standard (Sepsis-2) and revised (Sepsis-3) definitions for organ dysfunction in ED patients with infection.
METHODS: Consecutive ED patients admitted with presumed infection were prospectively enrolled over 3 years. Sufficient observational data were collected to calculate SIRS, qSOFA, SOFA, comorbidity, and mortality.
RESULTS: We enrolled 8,871 patients, with SIRS present in 4,176 (47.1%). SIRS was associated with increased risk of organ dysfunction (relative risk [RR] 3.5) and mortality in patients without organ dysfunction (OR 3.2). SIRS and qSOFA showed similar discrimination for organ dysfunction (area under the receiver operating characteristic curve, 0.72 vs 0.73). qSOFA was specific but poorly sensitive for organ dysfunction (96.1% and 29.7%, respectively). Mortality for patients with organ dysfunction was similar for Sepsis-2 and Sepsis-3 (12.5% and 11.4%, respectively), although 29% of patients with Sepsis-3 organ dysfunction did not meet Sepsis-2 criteria. Increasing numbers of Sepsis-2 organ system dysfunctions were associated with greater mortality.
CONCLUSIONS: SIRS was associated with organ dysfunction and mortality, and abandoning the concept appears premature. A qSOFA score ≥ 2 showed high specificity, but poor sensitivity may limit utility as a bedside screening method. Although mortality for organ dysfunction was comparable between Sepsis-2 and Sepsis-3, more prognostic and clinical information is conveyed using Sepsis-2 regarding number and type of organ dysfunctions. The SOFA score may require recalibration.
参考来源
- Williams JM, Greenslade JH, McKenzie JV, et al. Systemic Inflammatory Response Syndrome, Quick Sequential Organ Function Assessment, and Organ Dysfunction: Insights From a Prospective Database of ED Patients With Infection. Chest. 2016. PMID: 27876592. doi:10.1016/j.chest.2016.10.057
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。