爆发-抑制伴相同爆发与心脏骤停后脑氧合多模态指标的关联
该单中心回顾性研究纳入心脏骤停复苏后同时接受脑电图和颈静脉球血氧饱和度(SjvO2)或脑组织氧分压(PbtO2)监测的患者,将脑电图模式分为BSIB、恶性非BSIB和非恶性三组。结果显示BSIB组SjvO2高于非恶性组(β=12,95%CI 7.0-16.0),与恶性非BSIB组无差异;BSIB组颈静脉-动脉二氧化碳分压差低于恶性非BSIB组(β=-1.4,95%CI -2.6至-0.3)和非恶性组(β=-2.6,95%CI -4.1至-1.0);BSIB组颅内压低于恶性非BSIB组(β=-19.0,95%CI -32.5至-5.6);PbtO2在三组间调整后无显著差异。提示BSIB可能代表一种以氧代谢受损但氧输送和弥散保留为特征的PCABI亚型。
要点
- BSIB患者SjvO2较非恶性脑电图模式高12%(β=12,95%CI 7.0-16.0),但与恶性非BSIB模式无差异(β=3,95%CI -0.6至7.0)。
- BSIB患者颈静脉-动脉二氧化碳分压差较恶性非BSIB低1.4 mmHg(β=-1.4,95%CI -2.6至-0.3),较非恶性低2.6 mmHg(β=-2.6,95%CI -4.1至-1.0)。
- BSIB患者颅内压较恶性非BSIB模式低19.0 mmHg(β=-19.0,95%CI -32.5至-5.6)。
- BSIB患者PbtO2在调整模型中与恶性非BSIB模式相比无显著差异(β=4.0,95%CI -4.7至13.0)。
适用人群与场景
- 心脏骤停复苏后同时接受脑电图和颈静脉球血氧饱和度(SjvO2)或脑组织氧分压(PbtO2)监测的患者。
- 单中心回顾性研究,纳入标准为心脏骤停复苏后并进行了上述监测。
诊断标准与关键阈值
- 脑电图模式分为三类:BSIB(爆发-抑制伴相同爆发)、恶性非BSIB、非恶性。
- 原文未提及具体的脑电图判读界值或监测启动/停止阈值。
处置流程与药物剂量
- 原文未提及
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:单中心回顾性研究;样本量:SjvO2队列109例,PbtO2队列33例。
- 人群:心脏骤停复苏后接受脑电图和SjvO2或PbtO2监测的患者。
- 干预/暴露:按脑电图模式分组(BSIB、恶性非BSIB、非恶性),比较各组SjvO2、颈静脉-动脉二氧化碳分压差、PbtO2和颅内压。
- 主要终点结果:BSIB组SjvO2较非恶性组高(β=12,95%CI 7.0-16.0),与恶性非BSIB组无差异(β=3,95%CI -0.6至7.0);BSIB组颈静脉-动脉二氧化碳分压差较恶性非BSIB组低(β=-1.4,95%CI -2.6至-0.3),较非恶性组低(β=-2.6,95%CI -4.1至-1.0);BSIB组颅内压较恶性非BSIB组低(β=-19.0,95%CI -32.5至-5.6);PbtO2在调整模型中与恶
- 关键次要终点及不良事件:原文未提及。
证据类型、等级与局限
- 证据类型:单中心回顾性研究;证据等级或推荐强度:原文未提及。
- 局限:单中心、回顾性设计、样本量较小(SjvO2队列109例,PbtO2队列33例),原文未提及盲法或混杂控制细节。
对床旁实践的改变
- 对于心脏骤停后接受多模态脑氧合监测的患者,BSIB脑电图模式可能提示氧代谢受损但氧输送和弥散保留,需结合SjvO2、颈静脉-动脉二氧化碳分压差和颅内压综合解读,而非简单视为严重缺血。
- 原文未提及基于BSIB改变治疗决策的具体建议,不推荐仅凭BSIB调整氧疗或血流动力学目标。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: Burst-suppression with identical bursts (BSIB) is an electroencephalographic (EEG) pattern associated with severe post-cardiac arrest brain injury (PCABI). Whether modifiable mechanisms of brain injury underlie BSIB is unknown. We hypothesized BSIB is associated with impaired cerebral oxygen metabolism, reflected as pathologically elevated jugular bulb venous oxygen saturation (SjvO2), higher brain tissue oxygen tension (PbtO2), normal jugular bulb venous-to-arterial carbon dioxide gradient (PbCO2 gap, and lower intracranial pressure (ICP) compared to other EEG patterns.
METHODS: This single-center retrospective study included patients resuscitated from cardiac arrest who underwent EEG and SjvO2 or PbtO2 monitoring. We categorized EEG patterns as BSIB, malignant without BSIB, and non-malignant. Using mixed effects linear regression, we examined associations between EEG and SjvO2, PbCO2 gap, PbtO2, and ICP.
RESULTS: The SjvO2 and PbtO2 cohorts included 109 and 33 patients, respectively. SjvO2 did not differ between BSIB and malignant EEGs (β = 3; 95% CI, -0.6 to 7.0), but was higher with BSIB compared to non-malignant patterns (β = 12; 95% CI, 7.0 to 16.0). BSIB was associated with lower PbCO2 gap compared to malignant (β = -1.4; 95% CI, -2.6 to -0.3) and non-malignant (β = -2.6; 95% CI, -4.1 to -1.0) patterns. PbtO2 was highest with BSIB, but not significantly higher compared to malignant patterns in our adjusted model (β = 4.0; 95% CI, -4.7 to 13.0). ICP was lower in those with BSIB compared to malignant patterns (β = -19.0; 95% CI, -32.5 to -5.6).
INTERPRETATION: BSIB may represent a distinct subtype of PCABI characterized by impaired oxygen metabolism with preserved oxygen delivery and diffusion.
参考来源
- Faiver L, Tam J, Ratay CR, et al. Association between burst-suppression with identical bursts and multimodal measures of cerebral oxygenation after cardiac arrest. Resuscitation. 2026. PMID: 42901367. doi:10.1016/j.resuscitation.2026.111360
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。