指南与共识重症综合管理与镇静镇痛心脑血管急症

自主神经系统临床诊断测试的效用与最佳实践:美国自主神经学会与美国神经肌肉与电诊断医学会认可的共识声明

Utility and best practices for clinical diagnostic testing of the autonomic nervous system: A Consensus Statement Endorsed by the American Autonomic Society and the American Association of Neuromuscular & Electrodiagnostic Medicine.
指南 / 共识 · Clin Auton Res · 2026-09-21
一句话结论由合格人员按最佳实践操作的标准化自主神经反射功能测试有临床效用、经过充分验证、有证据基础且非研究性,应在适当时整合入临床实践。

美国自主神经学会召集自主神经专科写作委员会,回顾已发表证据与临床标准化自主神经反射功能测试的既定实践,制定本共识声明。声明总结了支持标准化自主神经反射功能测试的临床证据,涵盖神经退行性疾病、周围神经病、直立不耐受综合征和自身免疫性自主神经障碍等;描述了经过验证的测试组合——直立挑战、Valsalva动作、心血管迷走心率变异性测试和催汗测试——并关注生理学原理、技术标准和临床解读。声明为自主神经测试所需角色(自主神经技术员、监督临床医师和解读自主神经的医师)定义了最低标准,并讨论了儿科、妊娠和危重症人群的特殊考虑。结论认为,由合格人员按最佳实践执行的标准化自主神经反射功能测试有临床效用、经过充分验证、有证据基础且非研究性;在某些情况下对临床决策不可替代,应在适当时整合入临床实践。

要点

  • 标准化自主神经反射功能测试由合格人员按最佳实践执行时有临床效用、经过充分验证、有证据基础且非研究性。
  • 经过验证的测试组合包括直立挑战、Valsalva动作、心血管迷走心率变异性测试和催汗测试。
  • 声明为自主神经技术员、监督临床医师和解读自主神经的医师定义了最低标准。
  • 声明讨论了儿科、妊娠和危重症人群的特殊考虑。
  • 自主神经测试在某些情况下对临床决策不可替代,应在适当时整合入临床实践。

适用人群与场景

  • 神经退行性疾病、周围神经病、直立不耐受综合征和自身免疫性自主神经障碍等患者。
  • 儿科、妊娠和危重症人群需特殊考虑。

处置流程与药物剂量

  • 经过验证的测试组合包括直立挑战、Valsalva动作、心血管迷走心率变异性测试和催汗测试。
  • 自主神经测试所需角色包括自主神经技术员、监督临床医师和解读自主神经的医师,声明定义了各角色最低标准。

研究设计与关键结果

  • 美国自主神经学会召集自主神经专科写作委员会,回顾已发表证据和临床标准化自主神经反射功能测试的既定实践,制定本共识声明。
  • 声明总结了支持标准化自主神经反射功能测试的临床证据,涵盖神经退行性疾病、周围神经病、直立不耐受综合征和自身免疫性自主神经障碍等。
  • 声明描述了经过验证的测试组合——直立挑战、Valsalva动作、心血管迷走心率变异性测试和催汗测试——并关注生理学原理、技术标准和临床解读。
  • 声明为自主神经技术员、监督临床医师和解读自主神经的医师定义了最低标准。
  • 声明讨论了儿科、妊娠和危重症人群的特殊考虑,并回顾了新兴辅助技术。

证据类型、等级与局限

  • 证据类型:共识声明。
  • 声明基于已发表证据和既定实践,并建立在北美和欧洲专业学会先前发布的立场声明之上。

对床旁实践的改变

  • 作者认为标准化自主神经反射功能测试有临床效用、经过充分验证、有证据基础且非研究性,前提是由合格人员按最佳实践执行。
  • 作者认为自主神经测试在某些情况下对临床决策不可替代,应在适当时整合入临床实践。

指南或共识出处

  • 自主神经系统临床诊断测试的效用与最佳实践:美国自主神经学会与美国神经肌肉与电诊断医学会认可的共识声明(Clin Auton Res)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: Disorders of the autonomic nervous system are prevalent and associated with substantial morbidity, mortality and diagnostic delay. Standardized, laboratory-based autonomic function testing provides objective physiological data essential for diagnosing, staging, and monitoring autonomic disorders, yet no current consensus statement establishes best practices for the conduct, interpretation, and minimum quality standards of such testing.

METHODS: The American Autonomic Society convened a writing committee of autonomic specialists to review published evidence and established practices governing standardized autonomic reflex function testing in clinical settings. This consensus statement builds upon prior position statements published by North American and European professional societies.

RESULTS: We summarize the clinical evidence supporting standardized autonomic reflex function testing across a broad range of conditions, including neurodegenerative disorders, peripheral neuropathies, orthostatic intolerance syndromes, and autoimmune autonomic disorders. We describe the validated battery of tests -orthostatic challenge, Valsalva maneuver, cardiovagal heart rate variability testing, and sudomotor testing-with attention to physiological principles, technical standards, and clinical interpretation. Minimum standards are defined for the requisite roles in autonomic testing: the autonomic technician, supervising clinician, and interpreting autonomic physician. Special considerations for pediatric, pregnant, and critically ill populations are addressed, and emerging adjunctive techniques are reviewed.

CONCLUSION: Standardized autonomic reflex function testing is clinically useful, well validated, evidence-based, and non-investigational when performed by qualified personnel adhering to best practices. Autonomic testing is irreplaceable for clinical decision-making in certain circumstances and should be integrated into clinical practice when appropriate.

来源:Clin Auton Res,查看原文。版权归原作者所有。

参考来源

  1. Cortez MM, Cook G, Miglis MG, et al. Utility and best practices for clinical diagnostic testing of the autonomic nervous system: A Consensus Statement Endorsed by the American Autonomic Society and the American Association of Neuromuscular & Electrodiagnostic Medicine. Clin Auton Res. 2026. PMID: 42766240. doi:10.1007/s10286-026-01238-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。