急性严重创伤性脊髓损伤患者损伤部位监测:五家重症监护病房109例病例系列
该回顾性多中心病例系列分析了五家ICU共109例急性严重创伤性脊髓损伤成人患者,在损伤部位硬膜内放置监测探头,评估探头类型、放置方式、信号质量和安全性。所有患者均放置硬膜内压探头,67.9%同时放置微透析探头,44.0%同时放置氧探头;探头留置5.3±0.2天。信号质量大部分时间良好者占比分别为硬膜内压89.0%、微透析95.9%、氧79.2%。CT确认探头位置良好者除1例外均良好。主要并发症为脑脊液漏20.8%、假性脊膜膨出10.4%、伤口感染4.7%,未发生脊髓损伤、脑膜炎或血肿。探头可实时显示脊髓灌注压、脊髓自动调节、脊髓组织氧合和代谢,具有潜在临床指导价值。
要点
- 109例急性严重创伤性脊髓损伤成人患者中,所有患者放置硬膜内压探头,67.9%加微透析探头,44.0%加氧探头,探头留置5.3±0.2天。
- 信号质量大部分时间良好者:硬膜内压89.0%、微透析95.9%、氧79.2%;CT确认探头位置良好者除1例外均良好。
- 主要风险为脑脊液漏20.8%(其中81.8%需床旁缝合、9.1%需腰大池引流、9.1%需拔除探头)、假性脊膜膨出10.4%(81.8%无症状、18.2%需手术)、伤口感染4.7%(60.0%抗生素治愈、40.0%需手术清创)。
- 未观察到脊髓损伤、脑膜炎或血肿。
- 探头信号可用于研究,并可实时显示脊髓灌注压、脊髓自动调节、脊髓组织氧合和代谢,具有潜在临床指导价值。
适用人群与场景
- 五家ICU(Aarhus、Leuven、Ljubljana、London、Madrid)收治的109例急性严重创伤性脊髓损伤成人患者。
- 入院AIS分级为A级58.7%、B级19.3%、C级22.0%。
诊断标准与关键阈值
- 原文未提及
处置流程与药物剂量
- 在损伤部位硬膜内放置监测探头:所有患者放置硬膜内压探头,67.9%同时放置微透析探头,44.0%同时放置氧探头。
- 探头留置时间为5.3±0.2天(均值±标准误)。
- 脑脊液漏的处理:81.8%需床旁缝合,9.1%需腰大池引流,9.1%需拔除探头。
- 假性脊膜膨出的处理:81.8%无症状,18.2%需手术。
- 伤口感染的处理:60.0%经抗生素治愈,40.0%需手术清创。
红旗征与不能漏的情况
- 脑脊液漏(发生率20.8%):部分需床旁缝合、腰大池引流或拔除探头。
- 假性脊膜膨出(发生率10.4%):多数无症状,少数需手术。
- 伤口感染(发生率4.7%):部分需手术清创。
研究设计与关键结果
- 研究类型:回顾性多中心病例系列,共109例成人患者,来自五家ICU。
- 干预:在损伤部位硬膜内放置监测探头(硬膜内压探头全部患者,微透析探头67.9%,氧探头44.0%)。
- 主要结果:探头留置5.3±0.2天;信号质量大部分时间良好者占比为硬膜内压89.0%、微透析95.9%、氧79.2%;CT确认探头位置良好者除1例外均良好。
- 并发症:脑脊液漏20.8%,假性脊膜膨出10.4%,伤口感染4.7%;未观察到脊髓损伤、脑膜炎或血肿。
证据类型、等级与局限
- 证据类型:回顾性多中心病例系列(病例系列研究)。
- 局限:回顾性数据收集,通过问卷和病历回顾,样本量109例,非对照设计,原文未提及证据等级或推荐强度。
对床旁实践的改变
- 在急性严重创伤性脊髓损伤成人患者中,硬膜内监测探头可提供大部分时间良好的信号质量,但需警惕脑脊液漏、假性脊膜膨出和伤口感染。
- 探头信号目前主要用于研究,原文仅展示潜在临床价值示例,尚不能作为常规临床决策依据。
- 脑脊液漏多数需床旁缝合处理,少数需腰大池引流或拔除探头;伤口感染多数可抗生素治愈,部分需手术清创。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: We review the international experience of placing monitoring probes intrathecally at the injury site in patients with acute, severe traumatic spinal cord injuries. The aims are to assess the types of probes used, their placement, signal quality, and safety.
METHODS: We analyzed data from 109 adult patients managed in intensive care units in Aarhus, Leuven, Ljubljana, London, and Madrid. A questionnaire was distributed to all participating sites and data were retrospectively collected from each patient's medical record.
RESULTS: Admission American Spinal Injury Association (AIS) grade was A (58.7%), B (19.3%), or C (22.0%). The probes remained for 5.3 ± 0.2 days (mean ± standard error). All patients had intraspinal pressure probes, 67.9% also had microdialysis probes, and 44.0% also had oxygen probes. Signal quality was good most of the time in 89.0% (intraspinal pressure), 95.9% (microdialysis), and 79.2% (oxygen) of patients. Computed tomography (CT) obtained in 89.0% of patients confirmed good probe position in all but one patient. Cerebrospinal fluid leak occurred in 20.8% of patients, 81.8% of whom required bedside suturing, 9.1% of whom required lumbar drainage, and 9.1% of whom required probe removal. Pseudomeningocele developed in 10.4% patients, of whom 81.8% were asymptomatic and 18.2% required surgery. Wound infections were reported in 4.7% patients: 60.0% resolved with antibiotics and 40.0% required surgical debridement. There was no spinal cord damage, meningitis, or hematoma. Though the probe signals were used for research, we show examples of potential clinical value. The probes allow for visualization in real time of spinal cord perfusion pressure, spinal cord autoregulation, spinal cord tissue oxygenation, and metabolism.
CONCLUSIONS: The main risks of intrathecal monitoring probes are cerebrospinal fluid leak, pseudomeningocele, and wound infection. Spinal cord damage, meningitis, or hematoma have not been observed. The probes provide good quality data in most patients with acute, severe traumatic spinal cord injuries that could potentially be used to guide clinical management.
参考来源
- Ilochonwu LC, Asif H, Kopač C, et al. Monitoring from the Injury Site After Spinal Cord Injury: Case Series of 109 Patients from Five Intensive Care Units. Neurocrit Care. 2026. PMID: 42601564. doi:10.1007/s12028-026-02629-6
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。