跨肺压导向呼气末正压滴定对急性呼吸窘迫综合征患者肺动脉顺应性的影响:一项单中心随机对照初步病理生理研究
该单中心随机对照初步病理生理研究纳入40例接受有创机械通气不足72小时的成人ARDS患者,随机分为跨肺压导向PEEP滴定组(Ptp组,n=20)与经验性低潮气量肺保护性通气组(对照组,n=20)。主要终点为入组后72小时内肺动脉顺应性(Cpa)动态变化差异。Ptp组Cpa在72小时动态监测期间显著高于对照组(p=0.039),但Cpa随时间无显著变化且两组趋势无显著差异。两组右心室射血分数和氧输送指数的动态变化有显著差异(p<0.05),右心室舒张末横径/左心室舒张末横径比值及三尖瓣环收缩期位移的变化也有显著差异(p<0.05)。结论认为跨肺压导向PEEP滴定在维持更高Cpa和保护右心室功能方面优于传统肺保护性通气。
要点
- 在肺炎所致中重度ARDS成人患者中,跨肺压导向PEEP滴定组72小时内Cpa显著高于传统低潮气量肺保护性通气组(p=0.039)。
- 两组Cpa随时间无显著变化,且组间趋势无显著差异,提示差异主要来自组间整体水平而非时间演变。
- 两组右心室射血分数和氧输送指数的动态变化在随机化后72小时内差异显著(p<0.05)。
- 两组右心室舒张末横径/左心室舒张末横径比值及三尖瓣环收缩期位移的变化差异显著(p<0.05),提示右心室功能保护更优。
- 研究为单中心初步病理生理研究,样本量40例,结论需进一步验证。
适用人群与场景
- 成人ARDS患者,已接受有创机械通气不足72小时。
- 研究场景为中国某呼吸ICU。
- 结论针对肺炎所致中重度ARDS患者。
诊断标准与关键阈值
- ARDS诊断标准原文未提及具体条件与界值。
- 纳入标准:成人、诊断为ARDS、有创机械通气不足72小时。
- 排除标准原文未提及。
处置流程与药物剂量
- 第一步:将符合纳入标准的ARDS患者随机分为跨肺压导向PEEP滴定组或经验性低潮气量肺保护性通气组。
- 第二步:Ptp组以跨肺压为导向滴定PEEP;对照组采用经验性低潮气量肺保护性通气策略。
- 第三步:入组后72小时内动态监测肺动脉顺应性(Cpa)及右心室功能指标。
- 药物剂量、PEEP具体数值、跨肺压目标值原文未提及。
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:单中心、随机对照初步病理生理研究;样本量40例(Ptp组20例,对照组20例);单中心。
- 主要终点:入组后72小时内Cpa动态变化差异;Ptp组Cpa在72小时动态监测期间显著高于对照组(p=0.039)。
- Cpa随时间无显著变化,两组趋势无显著差异。
- 关键次要终点:右心室射血分数和氧输送指数的动态变化在72小时内组间差异显著(p<0.05);右心室舒张末横径/左心室舒张末横径比值及三尖瓣环收缩期位移的变化组间差异显著(p<0.05)。
- 不良事件原文未提及。
证据类型、等级与局限
- 证据类型:单中心、随机对照初步病理生理研究。
- 证据等级或推荐强度原文未提及。
- 局限:单中心、样本量小(40例)、初步研究,结论需进一步验证。
对床旁实践的改变
- 在肺炎所致中重度ARDS成人患者中,可考虑采用跨肺压导向PEEP滴定以维持更高肺动脉顺应性并保护右心室功能,但需注意证据来自单中心小样本初步研究。
- 传统经验性低潮气量肺保护性通气在右心室功能保护方面可能不如跨肺压导向策略,但原文未给出具体PEEP设置差异。
- 不适用人群及常见陷阱原文未提及。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the function of positive end-expiratory pressure (PEEP) titration guided by transpulmonary pressure (Ptp) with traditional lung-protective ventilation to optimize pulmonary arterial compliance (Cpa) in acute respiratory distress syndrome (ARDS) patients.
DESIGN: A single center, randomized controlled pilot pathophysiological study.
SETTING: A respiratory ICU in China.
PATIENTS/SUBJECTS: Adult patients diagnosed with ARDS who had received invasive mechanical ventilation for less than 72 hours.
INTERVENTIONS: Patients were randomized to the Ptp group or empirical low tidal volume lung-protective group.
MEASUREMENTS AND MAIN RESULTS: The primary endpoint was the difference in the Cpa dynamic changes between the two groups during the first 72 hours of intervention following enrollment. A total of 40 patients were included in the study, with 20 patients in the Ptp group and 20 patients in the control group. The Cpa in the Ptp group was 3.98 ± 0.46 mL/mm Hg at randomization, which was not significantly different from that in the control group (3.89 ± 0.40 mL/mm Hg). The Cpa in the Ptp group was significantly higher than that in the control group (p = 0.039) during the 72 hours of dynamic monitoring performed after enrollment. However, Cpa did not change significantly over time, and there was no significant difference in the trend between the two groups. There was a significant difference in the dynamic change of the right ventricular ejection fraction and oxygen delivery index between the two groups within 72 hours after randomization (p < 0.05). The change in the right ventricular end-diastolic transverse diameter/left ventricular end-diastolic transverse diameter ratio and in the tricuspid annular plane systolic excursion was significantly different between the two groups (p < 0.05).
CONCLUSIONS: Ptp-guided PEEP titration was superior to traditional lung-protective ventilation in maintaining a higher Cpa and preserving right ventricular function in patients with moderate-to-severe ARDS caused by pneumonia.
参考来源
- Tang X, Li T, Yang H, et al. The Effect of Transpulmonary Pressure-Guided Positive End-Expiratory Pressure Titration on Pulmonary Arterial Compliance in Acute Respiratory Distress Syndrome Patients: A Single-Center, Randomized Controlled Pilot Pathophysiological Study. Crit Care Explor. 2026. PMID: 42545865. doi:10.1097/CCE.0000000000001461
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。