聚磷酸盐基止血纱布在猪肢体创伤失血性休克模型中较QuikClot Combat Gauze保留远端灌注
该研究为前瞻性随机对照大动物肢体创伤失血性休克模型,比较聚磷酸盐(PolyP)基止血纱布与高岭土基Combat Gauze(CG)在标准化压迫和复苏方案下的效果,每组n=11。主要终点为生存时间和生存比例,次要终点包括远端股动脉血流、失血量、血流动力学、代谢状态和凝血。结果显示120分钟生存率(PolyP 90.9% vs CG 81.8%)和总失血量(1,780±219 vs 1,847±484 mL,p=0.72)无显著差异,首次止血成功率(63.6% vs 81.8%,p=0.64)也无显著差异;但远端搏动性股动脉血流恢复率PolyP组为90.9%,CG组为27.3%(p=0.0075)。作者认为这些发现支持将下游灌注纳入院前止血敷料的性能基准,并需进一步转化和现场评估。
要点
- 在猪肢体创伤失血性休克模型中,PolyP纱布组远端搏动性股动脉血流恢复率为90.9%,显著高于CG组的27.3%(p=0.0075)。
- PolyP组与CG组120分钟生存率分别为90.9%和81.8%,总失血量分别为1,780±219 mL和1,847±484 mL(p=0.72),均无显著差异。
- 首次止血成功率PolyP组为63.6%,CG组为81.8%(p=0.64),两组无显著差异。
- 两组血流动力学、代谢指标(乳酸、碱剩余、pH、血红蛋白)及全身凝血指标(凝血酶原时间、纤维蛋白原、活化部分凝血活酶时间)变化相似。
- 作者认为这些发现支持将下游灌注纳入院前止血敷料的性能基准,并需进一步转化和现场评估。
适用人群与场景
- 猪肢体创伤失血性休克模型,每组n=11,用于比较PolyP基止血纱布与高岭土基Combat Gauze的效果。
处置流程与药物剂量
- 在标准化压迫和复苏方案下,使用PolyP基止血纱布或高岭土基Combat Gauze进行止血。
研究设计与关键结果
- 研究类型为前瞻性、随机、对照大动物肢体创伤失血性休克模型,每组n=11,结局评估采用研究者盲法。
- 120分钟生存率:PolyP组90.9% vs CG组81.8%,无显著差异。
- 总失血量:PolyP组1,780±219 mL vs CG组1,847±484 mL(p=0.72),无显著差异。
- 首次止血成功率:PolyP组63.6% vs CG组81.8%(p=0.64),无显著差异。
- 远端搏动性股动脉血流恢复率:PolyP组90.9% vs CG组27.3%(p=0.0075),PolyP组显著高于CG组。
- 血流动力学、代谢指标(乳酸、碱剩余、pH、血红蛋白)及全身凝血指标(凝血酶原时间、纤维蛋白原、活化部分凝血活酶时间)两组变化相似。
证据类型、等级与局限
- 证据类型:前瞻性、随机、对照大动物(猪)实验研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为这些发现支持将下游灌注纳入院前止血敷料的性能基准,并需进一步转化和现场评估。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Uncontrolled hemorrhage remains the leading preventable cause of death after trauma. Current prehospital strategies emphasize rapid bleeding control, yet benchmark kaolin-based dressings may impair distal perfusion through intraluminal thrombosis. Polyphosphate (PolyP)-based dressings could offer effective hemostasis while maintaining arterial flow.
METHODS: In a prospective, randomized, controlled large-animal extremity trauma model with hemorrhagic shock, PolyP gauze was compared with kaolin-based Combat Gauze (CG) under a standardized compression and resuscitation protocol. Primary endpoints were survival time and survival proportion; secondary endpoints included distal femoral flow, blood loss, hemodynamics, metabolic status, and coagulation. Outcome assessment was investigator blinded.
RESULTS: Baseline characteristics were comparable between groups (n = 11 per group). Survival at 120 minutes (PolyP 90.9% vs. CG 81.8%) and total blood loss (1,780 ± 219 vs. 1,847 ± 484 mL, p = 0.72) did not differ significantly. First-pass hemostasis was achieved in 63.6% of PolyP- and 81.8% of CG-treated animals (p = 0.64). In contrast, distal pulsatile femoral flow was restored in 90.9% of PolyP-treated animals compared with 27.3% after CG (p = 0.0075). Hemodynamics, metabolic markers (lactate, base excess, pH, hemoglobin), and systemic coagulation assays (prothrombin time, fibrinogen, activated partial thromboplastin time) evolved similarly across groups.
CONCLUSION: In this swine extremity trauma model with shock, PolyP gauze provided hemostasis equivalent to the current benchmark while significantly improving distal arterial perfusion. These findings support expanding performance benchmarks for prehospital hemostatic dressings to include downstream perfusion and justify further translational and field evaluation. (J Trauma Acute Care Surg. 2026;101: 129-135. Copyright © 2026 Wolters Kluwer Health, Inc. All rights reserved.).