文献速递心脑血管急症呼吸衰竭与机械通气重症综合管理与镇静镇痛

急诊科医师判读的床旁超声与心脏科医师判读的会诊超声心动图识别肺栓塞患者右心室功能障碍的准确性比较

Accuracy of Point-of-Care Ultrasound Versus Consultative Echocardiography to Identify Right Ventricular Dysfunction in Emergency Department Patients With Pulmonary Embolism.
PubMed 文献 · Ann Emerg Med · 2026-06-18
一句话结论在急诊肺栓塞患者中,急诊医师判读的床旁超声识别右心室功能障碍的敏感性为76.8%、特异性为85.9%,与心脏科医师判读的会诊超声心动图总体一致性中等(kappa=0.63)。

该回顾性队列纳入194例同时接受急诊床旁超声和心脏科医师判读的会诊超声心动图的肺栓塞患者,由97名急诊医师操作床旁超声。床旁超声识别右心室功能障碍的敏感性为76.8%、特异性为85.9%,与会诊超声心动图总体一致率为81.4%(kappa=0.63,95%CI 0.51至0.75)。当会诊超声心动图判读为中度至重度右心室功能障碍时,床旁超声的准确性和一致性提高。急诊住院医师培训年限增加时,评分者间信度下降。

要点

  • 在194例急诊肺栓塞患者中,急诊医师判读的床旁超声识别右心室功能障碍的敏感性为76.8%、特异性为85.9%。
  • 床旁超声与会诊超声心动图总体一致率为81.4%,kappa=0.63(95%CI 0.51至0.75),一致性中等。
  • 当会诊超声心动图判读为中度至重度右心室功能障碍时,床旁超声的准确性和一致性提高。
  • 急诊住院医师培训年限增加时,床旁超声判读的评分者间信度下降。
  • 床旁超声右心室功能障碍定义为右心室大小大于左心室大小、三尖瓣环收缩期位移提示右心室收缩功能下降或两者兼有。

适用人群与场景

  • 急诊科肺栓塞患者,且同时接受了急诊床旁超声和心脏科医师判读的会诊超声心动图。

诊断标准与关键阈值

  • 床旁超声右心室功能障碍定义:右心室大小大于左心室大小、三尖瓣环收缩期位移提示右心室收缩功能下降,或两者兼有。
  • 会诊超声心动图右心室功能障碍分为无、轻度、中度至重度,依据右心室扩张、右心室功能减低或两者兼有的描述。

研究设计与关键结果

  • 回顾性队列纳入194例肺栓塞患者,由97名急诊医师操作床旁超声。
  • 床旁超声识别右心室功能障碍的敏感性为76.8%、特异性为85.9%(以会诊超声心动图为参照)。
  • 床旁超声与会诊超声心动图总体一致率为81.4%,kappa=0.63(95%CI 0.51至0.75)。
  • 当会诊超声心动图判读为中度至重度右心室功能障碍时,床旁超声的准确性和一致性提高。
  • 急诊住院医师培训年限增加时,评分者间信度下降。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在急诊肺栓塞患者中,急诊医师判读的床旁超声识别右心室功能障碍的敏感性为76.8%、特异性为85.9%,与会诊超声心动图一致性中等(kappa=0.63),当右心室功能障碍为中度至重度时准确性和一致性提高。
  • 急诊住院医师培训年限增加时,床旁超声判读的评分者间信度下降。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

STUDY OBJECTIVE: Assessment of right ventricular dysfunction facilitates risk stratification of emergency department (ED) patients with pulmonary embolism (PE). We evaluated the accuracy of emergency physician-interpreted point-of-care ultrasound (POCUS) compared with cardiologist-interpreted consultative echocardiography for right ventricular dysfunction in patients with PE.

METHODS: We developed a retrospective cohort using a regular expression algorithm to identify PE+ patients. Patients were included if they received both an ED POCUS and a cardiologist-interpreted consultative echocardiogram. Right ventricular dysfunction on POCUS was defined as RV size greater than left ventricular size, decreased RV systolic function by tricuspid annular plane systolic excursion, or both. Right ventricular dysfunction on consultative echocardiography was categorized as absent, mild, or moderate to severe using this verbiage to describe the presence of RV dilation, reduced RV function, or both. We report test characteristics (sensitivity and specificity), and agreement as inter-rater reliability coefficients (kappa) of POCUS stratified by right ventricular dysfunction severity and emergency residency training level.

RESULTS: In a 194-patient cohort with 97 emergency physician ultrasound operators, POCUS was 76.8% sensitive and 85.9% specific for the identification of right ventricular dysfunction compared with consultative echocardiography. There was 81.4% agreement, overall (kappa=0.63, 95% CI, 0.51 to 0.75). POCUS accuracy improved when right ventricular dysfunction was interpreted as moderate to severe on consultative ultrasound. Inter-rater reliability declined through residency training.

CONCLUSION: POCUS is 76.8% sensitive and 85.9% specific for right ventricular dysfunction in ED patients with PE compared with consultative echocardiography. There is moderate agreement between modalities. Accuracy and agreement improve when right ventricular dysfunction is moderate to severe.

来源:Ann Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Thomas AL, Rupp JD, Suszanski J, et al. Accuracy of Point-of-Care Ultrasound Versus Consultative Echocardiography to Identify Right Ventricular Dysfunction in Emergency Department Patients With Pulmonary Embolism. Ann Emerg Med. 2026. PMID: 42313044. doi:10.1016/j.annemergmed.2026.05.003

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。