文献速递心脑血管急症重症综合管理与镇静镇痛

定量瞳孔测量与其他神经预后标志物在心脏骤停后昏迷患者中的相关性:一项双中心研究

Correlation Between Quantitative Pupillometry and Other Markers for Neuroprognostication of Comatose Patients After Cardiac Arrest: A Bicentric Study.
PubMed 文献 · Crit Care Med · 2026-06-11
一句话结论心脏骤停后昏迷患者中,定量瞳孔光反射与脑电图、体感诱发电位及神经元特异性烯醇化酶密切相关,低qPLR和NPi≤2对不良预后高度特异,但预测性能未超过临床瞳孔光反射。

该双中心研究分析了2020至2024年间442例心脏骤停后昏迷成人,在骤停后48-72小时内采集定量瞳孔测量参数(NPi、最小和最大qPLR),评估其与临床特征、脑电图、体感诱发电位及48小时血清NSE的相关性,以及预测3个月时神经功能结局(CPC 1-2为良好)的价值。结果显示最小和最大qPLR在早期肌阵挛、双侧N20缺失、脑电图无反应及癫痫样放电时显著降低,与NSE水平显著相关。最小qPLR<2%、最大qPLR<13%及NPi≤2对不良预后高度特异(特异度分别为96.4%、96.4%、99%),但敏感度低;定性PLR敏感度高于最小和最大qPLR(38.9% vs 23.6%和19.0%,p<0.001),特异度相当。最小qPLR>9.5%和最大qPLR>25.5%与良好预后相关,但预测良好结局的能力有限。

要点

  • 心脏骤停后昏迷患者中,最小qPLR<2%(特异度96.4%,敏感度23.6%)、最大qPLR<13%(特异度96.4%,敏感度19.0%)和NPi≤2(特异度99%,敏感度34%)对不良预后高度特异但敏感度低。
  • 定性瞳孔光反射敏感度高于最小和最大qPLR(38.9% vs 23.6%和19.0%,p<0.001),特异度相当,定量瞳孔测量预测性能未超过临床定性评估。
  • 最小qPLR>9.5%(特异度83.2%,敏感度31.1%)和最大qPLR>25.5%(特异度62.2%,敏感度65.5%)与良好预后相关,但预测良好结局的能力有限。
  • 最小和最大qPLR在早期肌阵挛、双侧N20缺失、脑电图无反应及癫痫样放电时显著降低(p<0.001或p=0.03/0.05),与48小时血清NSE水平显著相关(Spearman Rho=-0.283和R=-0.444,p<0.001)。
  • qPLR与脑电图背景抑制相关:抑制背景较不连续和连续背景qPLR显著降低(p<0.001)。

适用人群与场景

  • 心脏骤停后昏迷成人,来自瑞士洛桑大学医院和法国巴黎科尚医院两个中心的前瞻性登记数据库。
  • 瞳孔测量参数在心脏骤停后48-72小时内获取。

诊断标准与关键阈值

  • 良好结局定义为3个月时脑功能分类(CPC)1-2级。
  • 最小qPLR<2%、最大qPLR<13%、NPi≤2与不良预后相关(特异度分别为96.4%、96.4%、99%;敏感度分别为23.6%、19.0%、34%)。
  • 最小qPLR>9.5%和最大qPLR>25.5%与良好预后相关(特异度分别为83.2%、62.2%;敏感度分别为31.1%、65.5%)。

研究设计与关键结果

  • 双中心研究,纳入2020至2024年间442例心脏骤停后昏迷成人,分析前瞻性登记数据,无干预。
  • 最小和最大qPLR在早期肌阵挛、双侧N20体感诱发电位缺失、脑电图无反应及癫痫样放电时显著降低(p<0.001或p=0.03/0.05)。
  • 脑电图背景抑制时qPLR较不连续和连续背景显著降低(p<0.001)。
  • 48小时血清NSE与最小qPLR(Spearman Rho=-0.283,p<0.001)和最大qPLR(R=-0.444,p<0.001)显著相关。
  • 最小qPLR<2%(特异度96.4%,敏感度23.6%)、最大qPLR<13%(特异度96.4%,敏感度19.0%)、NPi≤2(特异度99%,敏感度34%)与不良预后相关。
  • 定性PLR敏感度高于最小和最大qPLR(38.9% vs 23.6%和19.0%,p<0.001),特异度相当。
  • 最小qPLR>9.5%(特异度83.2%,敏感度31.1%)和最大qPLR>25.5%(特异度62.2%,敏感度65.5%)与良好预后相关。

证据类型、等级与局限

  • 证据类型:双中心前瞻性登记研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在心脏骤停后昏迷患者中,定量瞳孔测量参数(低qPLR和NPi≤2)对不良预后高度特异,但敏感度低,且预测性能未超过临床定性瞳孔光反射;高qPLR对良好预后的预测能力有限。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: The prognostic role of quantitative pupillometry in comatose patients after cardiac arrest (CA) has been recently described, but data on quantitative pupillary light reflex (qPLR) are limited, especially in a multimodal approach and regarding good outcome. We assessed qPLR correlations with clinical features, electroencephalogram (EEG), somatosensory evoked potentials (SSEPs), and neuron-specific enolase (NSE), as well as qPLR prognostic values toward poor and good outcomes.

DESIGN, SETTINGS, AND PATIENTS: Bicentric study (Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland and Cochin Hospital, Paris, France), analyzing prospective registries of comatose adults with pupillometry parameters obtained during the first 48-72 hours after CA. Neurological Pupil index (NPi), lowest (minimum qPLR), and highest values (maximum qPLR) of qPLR were collected. Predictive performances in terms of Cerebral Performance Categories (CPCs) level at 3 months (good outcome: CPC 1-2) were calculated.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Between 2020 and 2024, 442 patients were included. Minimum and maximum qPLRs were significantly lower in case of early myoclonus ( p < 0.001), bilateral N20 SSEP absence ( p < 0.001), unreactive EEG ( p < 0.001), and epileptiform EEG ( p = 0.03 and 0.05). qPLR was also significantly lower with suppressed EEG, compared with discontinuous and continuous background ( p < 0.001). Serum NSE level at 48 hours was significantly correlated with minimum (Spearman Rho = -0.283; p < 0.001) and maximum qPLRs ( R = -0.444; p < 0.001). Minimum qPLR less than 2% (96.4% specificity, 23.6% sensitivity), maximum qPLR less than 13% (96.4% specificity, 19.0% sensitivity), and NPi less than or equal to 2 (99% specificity, 34% sensitivity) robustly correlated with poor outcome. Notably, qualitative PLR had higher sensitivity than minimum and maximum qPLRs (38.9 vs. 23.6 and 19.0%, respectively; p < 0.001) with comparable specificity. A minimum qPLR greater than 9.5% (83.2% specificity, 31.1% sensitivity) and a maximum qPLR greater than 25.5% (62.2% specificity, 65.5% sensitivity) correlated with good outcome.

CONCLUSIONS: In comatose patients after CA, qPLR is tightly correlated with other prognostic markers; low qPLR and NPi less than or equal to 2 appeared highly specific for poor outcome, but performances do not exceed that of clinical PLR. Finally, high qPLR remained limited in predicting a good outcome.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Benghanem S, Novy J, Cariou A, et al. Correlation Between Quantitative Pupillometry and Other Markers for Neuroprognostication of Comatose Patients After Cardiac Arrest: A Bicentric Study. Crit Care Med. 2026. PMID: 42274301. doi:10.1097/CCM.0000000000007210

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。