液晶静脉定位仪对幼儿静脉置管效果的影响:一项随机试验
本研究为前瞻性随机对照试验,纳入105例0-3岁需经外周静脉置管的儿科急诊患儿,随机分为液晶静脉定位仪组(n=50)与传统体表标志法组(n=55)。主要终点首次穿刺成功率在定位仪组显著高于对照组(86.0% vs 54.5%;绝对差31.5%;95%CI 15.2-47.8%)。定位仪组中位静脉定位时间(16.5 vs 60.0 s)和中位总置管时间(40.0 vs 185.0 s)均显著缩短,中位穿刺次数亦显著减少(校正率比0.77;95%CI 0.66-0.90)。多因素分析显示器械辅助是首次穿刺成功的独立预测因素(校正OR 3.35;95%CI 1.13-9.95)。
要点
- 0-3岁儿科急诊患儿使用液晶静脉定位仪行经外周静脉置管,首次穿刺成功率86.0% vs 传统体表标志法54.5%,绝对差31.5%(95%CI 15.2-47.8%)。
- 定位仪组中位静脉定位时间16.5 s vs 对照组60.0 s,中位总置管时间40.0 s vs 185.0 s,均显著缩短。
- 定位仪组中位穿刺次数显著减少,校正率比0.77(95%CI 0.66-0.90)。
- 多因素分析中器械辅助是首次穿刺成功的独立预测因素,校正OR 3.35(95%CI 1.13-9.95)。
- 两组基线特征可比,研究在儿科急诊开展,纳入0-3岁需经外周静脉置管患儿。
适用人群与场景
- 0-3岁需经外周静脉置管的患儿,在儿科急诊科纳入。
- 两组基线特征可比。
处置流程与药物剂量
- 研究组使用液晶静脉定位仪(基于近红外技术)辅助经外周静脉置管。
- 对照组采用传统体表标志法行经外周静脉置管。
研究设计与关键结果
- 前瞻性随机对照试验,共纳入105例0-3岁需经外周静脉置管的儿科急诊患儿,随机分为液晶静脉定位仪组(n=50)与传统体表标志法组(n=55)。
- 主要终点首次穿刺成功率:定位仪组86.0% vs 对照组54.5%,绝对差31.5%(95%CI 15.2-47.8%)。
- 中位静脉定位时间:定位仪组16.5 s vs 对照组60.0 s。
- 中位总置管时间:定位仪组40.0 s vs 对照组185.0 s。
- 中位穿刺次数:定位仪组较对照组显著减少,校正率比0.77(95%CI 0.66-0.90)。
- 多因素分析:器械辅助是首次穿刺成功的独立预测因素,校正OR 3.35(95%CI 1.13-9.95)。
证据类型、等级与局限
- 证据类型:前瞻性随机对照试验。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在0-3岁儿科急诊患儿经外周静脉置管时,使用液晶静脉定位仪与本研究中更高的首次穿刺成功率、更少穿刺次数和更短操作时间相关。
- 本研究结果来自儿科急诊0-3岁需经外周静脉置管患儿,不适用于其他年龄或场景的推断。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND AND IMPORTANCE: Peripheral intravenous catheterization (PIVC) in young children is notoriously challenging because of factors like poor patient cooperation and small vessel diameter. Repeated attempts cause distress and delay critical emergency treatment.
OBJECTIVES: This study aimed to evaluate the effect of a novel liquid crystal display-based near-infrared vein locator on PIVC performance in children aged under 3 years.
DESIGN: This is a prospective, randomized controlled trial.
SETTINGS AND PARTICIPANTS: A total of 105 children aged 0-3 years requiring PIVC were enrolled in a pediatric emergency department.
INTERVENTION: Participants were randomly assigned to undergo PIVC using either a liquid crystal vein locator (study group, n = 50) or the traditional landmark-based method (control group, n = 55).
OUTCOME MEASURES AND ANALYSIS: The primary endpoint was the first-attempt success rate. Secondary endpoints included the number of puncture attempts, vein localization time, and total insertion time. Multivariable logistic and Poisson regression models were used to adjust for covariates, such as vein difficulty and patient demographics. Analyses included effect sizes with 95% confidence intervals (CIs).
MAIN RESULTS: The baseline characteristics of both groups were comparable. The first-attempt success rate was significantly higher in the study group compared to the control group (86.0% vs. 54.5%; absolute difference: 31.5%; 95% CI: 15.2-47.8%). The study group also demonstrated a significantly shorter median vein localization time (16.5 vs. 60.0 s) and median total insertion time (40.0 vs. 185.0 s). In addition, the device significantly reduced the median number of puncture attempts (adjusted rate ratio: 0.77; 95% CI: 0.66-0.90). Multivariable analysis revealed that device assistance was an independent predictor of first-attempt success (adjusted odds ratio: 3.35; 95% CI: 1.13-9.95).
CONCLUSION: In this study, the use of a liquid crystal vein locator was associated with a significantly higher first-attempt success rate, fewer puncture attempts, and reduced procedural times for PIVC in young children.
参考来源
- Wu HP, Guo BC, Chang YJ, et al. Effect of a liquid crystal vein locator on intravenous catheterization in young children: a randomized trial. Eur J Emerg Med. 2026. PMID: 42152760. doi:10.1097/MEJ.0000000000001355
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。