文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

超声评估肋间肌增厚分数联合膈肌功能对神经重症患者撤机拔管结局的预测价值

[Predictive value of ultrasound-assessed thickening fraction of intercostal muscle combined with diaphragmatic function for weaning and extubation outcomes in neurocritically ill patients].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2026-01-01
一句话结论神经重症有创通气患者自主呼吸试验结束时,超声测肋间肌增厚分数联合膈肌移动度及膈肌增厚分数对撤机拔管成功有较高预测价值,三者联合AUC 0.972。

该回顾性病例对照研究纳入111例神经重症经口气管插管有创通气患者,按撤机拔管结局分为失败组32例和成功组79例。自主呼吸试验结束时超声测量显示,撤机失败组肋间肌增厚分数高于成功组,膈肌移动度和膈肌增厚分数低于成功组。多因素Logistic回归显示,肋间肌增厚分数升高、膈肌移动度升高和膈肌增厚分数升高均为撤机拔管成功的独立影响因素。三者联合预测撤机成功的AUC为0.972,灵敏度88.6%,特异度96.9%。撤机失败组ICU住院时间、总住院时间和总机械通气时间均长于成功组。

要点

  • 神经重症有创通气患者SBT结束时超声测TFic、DE、DTF,三者联合预测撤机拔管成功AUC 0.972(95%CI 0.948-0.997),灵敏度88.6%,特异度96.9%。
  • 撤机失败组SBT结束时TFic高于成功组[15.76%(13.12%,21.24%)vs. 10.00%(8.33%,13.33%)],DE和DTF低于成功组。
  • 多因素Logistic回归示TFic升高(OR=0.731,95%CI 0.583-0.917,P=0.007)、DE升高(OR=4.494,95%CI 1.663-12.146,P=0.003)、DTF升高(OR=1.381,95%CI 1.078-1.770,P=0.011)为撤机拔管成功的独立影响因素。
  • 撤机失败组ICU住院时间、总住院时间和总机械通气时间均长于成功组,提示撤机失败与住院负担增加相关。
  • 单因素分析示入院GCS评分、拔管前睁眼和运动评分、气管插管气囊漏气试验漏气量、拔管前咳嗽能力、SBT结束时RSBI在两组间差异有统计学意义(均P<0.05)。

适用人群与场景

  • 神经重症监护病房收治的经气管插管行有创机械通气的神经重症患者,年龄18至79岁(原文排除年龄<18岁或≥80岁者)。
  • 原文排除治疗放弃或自动出院者、超声图像不清者、拔管前已行气管切开者及临床资料不完整者。

诊断标准与关键阈值

  • 撤机拔管结局分组:根据撤机拔管结局分为撤机失败组和撤机成功组。
  • 超声指标于自主呼吸试验结束时测量:肋间肌吸气末厚度(ICMTei)、肋间肌呼气末厚度(ICMTee)、肋间肌增厚分数(TFic);膈肌移动度(DE)、膈肌吸气末厚度(DTei)、膈肌呼气末厚度(DTee)、膈肌增厚分数(DTF)。
  • TFic、DE、DTF三者联合预测撤机拔管成功的ROC曲线AUC为0.972(95%CI 0.948-0.997,P<0.001),灵敏度88.6%,特异度96.9%。

研究设计与关键结果

  • 研究类型:回顾性病例对照研究;单中心(皖南医学院第一附属医院/弋矶山医院神经内科ICU);时间2023年4月至2025年4月;初始纳入233例,排除后最终分析111例,撤机失败组32例、撤机成功组79例。
  • 单因素分析:入院GCS评分、拔管前睁眼和运动评分、气囊漏气试验漏气量、拔管前咳嗽能力、SBT结束时RSBI两组间差异有统计学意义(均P<0.05)。
  • SBT结束时撤机失败组TFic高于成功组[15.76%(13.12%,21.24%)vs. 10.00%(8.33%,13.33%),P<0.05];DE低于成功组[1.10(1.05,1.20)cm vs. 1.36(1.25,1.45)cm,P<0.05];DTF低于成功组[18.75%(16.85%,24.75%)vs. 27.27%(22.73%,31.58%),P<0.05]。
  • 多因素Logistic回归:TFic升高OR=0.731(95%CI 0.583-0.917,P=0.007),DE升高OR=4.494(95%CI 1.663-12.146,P=0.003),DTF升高OR=1.381(95%CI 1.078-1.770,P=0.011),均为撤机拔管成功的独立影响因素。
  • 三者联合预测撤机成功AUC 0.972(95%CI 0.948-0.997,P<0.001),灵敏度88.6%,特异度96.9%;单独应用TFic、DE、DTF均有一定预测价值。
  • 住院结局:撤机失败组ICU住院时间长于成功组[31.00(18.25,49.25)天 vs. 20.00(8.00,32.00)天];总住院时间长于成功组[34.50(22.00,50.00)天 vs. 25.00(16.00,37.00)天];总机械通气时间长于成功组[18.50(12.00,30.25)天 vs. 8.00(3.00,10.00)天],均P<0.05。

证据类型、等级与局限

  • 证据类型:单中心回顾性病例对照研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对于神经重症经气管插管有创通气患者,可在自主呼吸试验结束时用超声测量TFic、DE和DTF,三者联合对撤机拔管成功有较高预测价值(AUC 0.972)。
  • 原文结果提示TFic升高与撤机拔管成功几率降低相关(OR=0.731),DE升高(OR=4.494)和DTF升高(OR=1.381)与成功几率升高相关,可作为床旁评估撤机条件的参考指标。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the predictive value of ultrasound evaluation of intercostal muscle combined with diaphragmatic function for weaning and extubation outcomes in neurocritically ill patients.

METHODS: A retrospective case-control study was performed. Clinical data of patients receiving invasive mechanical ventilation via tracheal intubation admitted to the neurology intensive care unit (ICU) of The First Affiliated Hospital of Wannan Medical University (Yijishan Hospital of Wannan Medical University) from April 2023 to April 2025 were collected. Patients were divided into a weaning failure group and a weaning success group according to weaning and extubation outcomes. General baseline data, eye opening and motor reaction scores before extubation, air leakage volume of tracheal intubation cuff leak test, cough ability before extubation, routine blood test and blood biochemical indicators within 48 hours before extubation, and basic vital signs, respiratory mechanics parameters, arterial blood gas analysis results as well as intercostal muscle function indicators [intercostal muscle thickness at the end of inspiration (ICMTei), intercostal muscle thickness at the end of expiration (ICMTee), thickening fraction of intercostal muscle (TFic)] and diaphragmatic function indicators [diaphragmatic excursion (DE), diaphragmatic thickness at the end of inspiration (DTei), diaphragmatic thickness at the end of expiration (DTee), diaphragmatic thickening fraction (DTF)] assessed by ultrasound at the end of spontaneous breathing trial (SBT) were compared between the two groups. Meanwhile, the inpatient outcome indicators of patients were collected. Binary multivariate Logistic regression analysis was used to screen the influencing factors of weaning and extubation outcomes in neurocritically ill patients undergoing invasive mechanical ventilation via tracheal intubation. Receiver operator characteristic curve (ROC curve) was plotted to analyze the predictive value of the combination of TFic, DE and DTF for weaning and extubation outcomes in neurocritically ill patients undergoing invasive mechanical ventilation via tracheal intubation.

RESULTS: A total of 233 neurocritically ill patients undergoing invasive mechanical ventilation via tracheal intubation were initially enrolled. After excluding 40 patients aged<18 years or ≥80 years, 55 patients with treatment abandonment or voluntary discharge, 11 patients with unclear ultrasound images, 5 patients undergoing tracheotomy before extubation and 11 patients with incomplete clinical data, 111 patients were finally included in the analysis, including 32 cases in the weaning failure group and 79 cases in the weaning success group. Univariate analysis showed that there were statistically significant differences in Glasgow Coma Scale (GCS) score at admission, eye opening and motor action scores before extubation, air leakage volume of tracheal intubation cuff leak test, cough ability before extubation, rapid shallow breathing index (RSBI) at the end of SBT (all P<0.05). At the end of SBT, TFic in the weaning failure group was higher than that in the weaning success group [15.76% (13.12%, 21.24%) vs. 10.00% (8.33%, 13.33%), P<0.05], while DE and DTF were lower than those in the weaning success group [DE (cm): 1.10 (1.05, 1.20) vs. 1.36 (1.25, 1.45), DTF: 18.75% (16.85%, 24.75%) vs. 27.27% (22.73%, 31.58%), both P<0.05]. Multivariate Logistic regression analysis showed that elevated TFic [odds ratio (OR)=0.731, 95% confidence interval (95%CI) was 0.583-0.917, P=0.007], elevated DE (OR=4.494, 95%CI was 1.663-12.146, P=0.003) and elevated DTF (OR=1.381, 95%CI was 1.078-1.770, P=0.011) were independent influencing factors for successful weaning and extubation in neurocritically ill patients undergoing invasive mechanical ventilation via tracheal intubation. ROC curve analysis showed that TFic, DE and DTF alone had certain predictive value for successful weaning in neurocritically ill patients undergoing invasive mechanical ventilation via tracheal intubation, and the combined application of the three indicators achieved the highest predictive value, with an area under the ROC curve (AUC) of 0.972 (95%CI was 0.948-0.997, P<0.001), a sensitivity of 88.6% and a specificity of 96.9%. Analysis of hospital outcome indicators showed that length of ICU stay, total length of hospital stay and total mechanical ventilation duration in the weaning failure group were longer than those in the weaning success group [length of ICU stay (days): 31.00 (18.25, 49.25) vs. 20.00 (8.00, 32.00), total length of hospital stay (days): 34.50 (22.00, 50.00) vs. 25.00 (16.00, 37.00), total mechanical ventilation duration (days): 18.50 (12.00, 30.25) vs. 8.00 (3.00, 10.00), all P<0.05].

CONCLUSIONS: Ultrasound assessment of TFic combined with DE and DTF has high application value in predicting successful weaning and extubation in neurocritically ill patients.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Wang K, Fan X, Zhang W, et al. [Predictive value of ultrasound-assessed thickening fraction of intercostal muscle combined with diaphragmatic function for weaning and extubation outcomes in neurocritically ill patients]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2026. PMID: 42200247. doi:10.3760/cma.j.cn121430-20250828-00462

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。