文献速递心脑血管急症重症综合管理与镇静镇痛

经下颌下颈内动脉测量搏动指数:替代经颞窗评估的可行方法

Pulsatility Index Measurement via the Submandibular Internal Carotid Artery: An Alternative to Transcranial Assessment.
PubMed 文献 · Neurocrit Care · 2026-04-06
一句话结论单中心回顾性研究显示,经下颌下窗测得的颈内动脉搏动指数与经颞窗大脑中动脉搏动指数强相关(r=0.894),颞窗不可用时作者认为可联合其他颅内压替代指标综合评估。

本研究为单中心回顾性观察研究,纳入2024年5月至9月ICU收治的神经重症患者,在同一次检查中分别经颞窗测大脑中动脉搏动指数(MCA-PI)和经下颌下窗测颈内动脉搏动指数(ICA-PI)。共分析46例患者、116次测量,主要诊断为蛛网膜下腔出血52次(44.8%)、脑出血21次(18.1%)、脑梗死9次(7.8%)、创伤性脑损伤8次(6.9%)。MCA-PI中位数1.11(IQR 0.87–1.36),ICA-PI中位数1.09(IQR 0.86–1.37),两者相关系数0.894(MCA-PI = 0.946 × ICA-PI + 0.057)。作者认为在颞窗不可用时,ICA-PI可与其他颅内压替代标志物联合用于综合评估。

要点

  • 46例神经重症患者共116次测量,经下颌下窗ICA-PI中位数1.09(IQR 0.86–1.37),经颞窗MCA-PI中位数1.11(IQR 0.87–1.36)。
  • ICA-PI与MCA-PI相关系数0.894(MCA-PI = 0.946 × ICA-PI + 0.057),在不同类型脑损伤中呈强相关。
  • 原文指出经颞窗测量PI在多达20%的患者中无法评估,而经下颌下窗在所有病例中均可测得ICA-PI。
  • 作者认为在神经重症监护中,颞窗不可用时可联合其他颅内压替代标志物使用ICA-PI进行综合评估。

适用人群与场景

  • 本研究纳入2024年5月至2024年9月单中心ICU治疗神经疾病期间行经颅超声检查的病例,共46例患者、116次测量。
  • 患者年龄67岁(IQR 49–74),男性57次测量(49.1%);主要诊断为蛛网膜下腔出血52次(44.8%)、脑出血21次(18.1%)、脑梗死9次(7.8%)、创伤性脑损伤8次(6.9%)。

研究设计与关键结果

  • 单中心、回顾性、观察性研究,纳入46例患者共116次测量,在同一次检查中同时获取经颞窗MCA-PI与经下颌下窗ICA-PI。
  • MCA-PI中位数1.11(IQR 0.87–1.36),ICA-PI中位数1.09(IQR 0.86–1.37)。
  • ICA-PI与MCA-PI相关系数0.894,回归方程为MCA-PI = 0.946 × ICA-PI + 0.057。
  • 作者结论:尽管纳入多种神经重症疾病,经下颌下窗ICA-PI与传统经颞窗MCA-PI强相关;颞窗不可用时,ICA-PI可与其他颅内压替代标志物联合用于综合评估。

证据类型、等级与局限

  • 证据类型:单中心、回顾性、观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在神经重症监护中,当经颞窗无法获得MCA-PI时,经下颌下窗测得的ICA-PI可与其他颅内压替代标志物联合用于综合评估。
  • 原文指出经颞窗测量PI在多达20%的患者中无法评估,而经下颌下窗在所有病例中均可测得ICA-PI。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND/OBJECTIVE: Pulsatility index (PI) measurements using transcranial color flow imaging via the temporal bone are one of the clinical substitutes for invasive intracranial pressure (ICP) monitoring. Although the PI measurements obtained through this window are commonly used, they cannot be evaluated in up to 20% of the patients. Given that PI in the internal carotid artery (ICA) can be easily measured through the submandibular window in all cases, this study aimed to investigate whether PI measurements through the submandibular window could be used as a substitute for PI measurements in the middle cerebral artery (MCA).

METHODS: This single-center, retrospective, observational study included cases from our intensive care unit between May 2024 and September 2024, in which transcranial ultrasound was performed during treatment of neurological disorders. The PI measurements from the temporal (MCA-PI) and submandibular (ICA-PI) windows were obtained at the same situation; the correlation between ICA-PI and MCA-PI was evaluated across various brain injuries using Pearson's correlation coefficient.

RESULTS: Data from 46 patients, totaling 116 measurements, were analyzed. The patients included 57 (49.1%) male patients aged 67 (interquartile range [IQR], 49-74) years. The primary diagnoses were subarachnoid hemorrhage [n = 52 (44.8%)], intracerebral hemorrhage [n = 21 (18.1%)], cerebral infarction [n = 9 (7.8%)], and traumatic brain injury [n = 8 (6.9%)]. The median MCA-PI was 1.11 [IQR: 0.87-1.36] and the median ICA-PI was 1.09 [IQR: 0.86-1.37]. A significant correlation was observed between the ICA-PI and MCA-PI, with a correlation coefficient of 0.894 (MCA-PI = 0.946 × ICA-PI + 0.057).

CONCLUSIONS: Despite the inclusion of various neurocritical disorders, the ICA-PI through the submandibular window was strongly correlated with the conventional PI (i.e., MCA-PI through the temporal window). In neurocritical care, the ICA-PI may be used in combination with other ICP surrogate markers for integrated assessment when the view through the temporal window is unavailable.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Fujimoto Y, Numata K, Sakuma A, et al. Pulsatility Index Measurement via the Submandibular Internal Carotid Artery: An Alternative to Transcranial Assessment. Neurocrit Care. 2026. PMID: 41942815. doi:10.1007/s12028-026-02505-3

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。