严重热力与创伤患者循环NET衍生染色质及核小体的定性与定量分析
本研究评估严重热力伤与创伤患者全血和血浆中中性粒细胞来源游离DNA(cfDNA)数量与质量的动态变化。烧伤队列96例、创伤队列147例,血浆cfDNA用SYTOX Green荧光定量,提取DNA行电泳测大小,并对烧伤患者新鲜全血行微流控捕获NET衍生染色质。结果显示烧伤伤后1–14天及创伤<1–72小时血浆cfDNA较健康对照显著升高,烧伤与创伤血浆均可见约150碱基对的核小体条带,创伤超早期(<1小时)样本可检出核小体寡聚体,核小体条带密度与cfDNA浓度相关;微流控捕获显示烧伤全血循环NET衍生染色质升高,伤后第1天尤为明显。作者认为NET衍生染色质、cfDNA和核小体在严重烧伤和创伤后升高,其动态变化支持其参与炎症并可作为关键生物标志物。
要点
- 烧伤患者伤后1–14天血浆cfDNA较健康对照显著升高。
- 创伤患者伤后<1–72小时血浆cfDNA较健康对照显著升高。
- 烧伤与创伤血浆电泳均见约150碱基对的核小体条带,创伤超早期(<1小时)样本检出核小体寡聚体。
- 核小体条带密度与cfDNA浓度相关。
- 微流控捕获显示烧伤全血循环NET衍生染色质升高,伤后第1天尤为明显。
适用人群与场景
- 严重热力伤患者(烧伤队列n=96)与严重创伤患者(创伤队列n=147)。
- 健康对照用于生成NET阳性对照(刺激全血或分离的中性粒细胞)。
研究设计与关键结果
- 研究类型为对两个队列(烧伤n=96、创伤n=147)血液样本的定性与定量分析。
- 血浆cfDNA用SYTOX Green荧光定量,提取DNA行电泳测大小,并对烧伤患者新鲜全血行微流控捕获NET衍生染色质。
- 烧伤伤后1–14天及创伤<1–72小时血浆cfDNA较健康对照显著升高。
- 烧伤与创伤血浆电泳均见约150碱基对的核小体条带,创伤超早期(<1小时)样本检出核小体寡聚体;核小体条带密度与cfDNA浓度相关。
- 微流控捕获显示烧伤全血循环NET衍生染色质升高,伤后第1天尤为明显。
证据类型、等级与局限
- 证据类型:对烧伤与创伤两个患者队列血液样本的定性与定量分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为NET衍生染色质、cfDNA和核小体在严重烧伤和创伤后升高,其动态变化支持其参与炎症并可作为关键生物标志物。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: This study evaluates the dynamic changes in the quantity and quality of neutrophil-derived cell-free DNA (cfDNA) in whole blood and plasma samples from severe thermal and traumatically injured patients.
BACKGROUND: Neutrophil-derived cfDNA, a component of neutrophil extracellular traps (NETs), is released during immune responses to injury and infection. Excessive NET formation mediates inflammation, tissue damage, and coagulopathy. Increased cfDNA levels in burn and trauma patients are reported to be associated with poor clinical outcomes, indicating their potential as biomarkers for predicting sepsis and MODS.
METHODS: Blood samples were obtained from two cohorts of burns (n = 96) and trauma (n = 147) patients. Neutrophil-derived cfDNA was quantified in plasma by SYTOX Green fluorescence and the size of extracted DNA was measured by electrophoresis. A microfluidic assay was also performed to capture NET-derived chromatin from burn patients' fresh whole blood samples. Captured NETs were stained with SYTOX green and anti-citrullinated histone antibodies. Stimulated whole blood or isolated neutrophils from healthy controls were used to generate NETs as positive controls.
RESULTS: Circulating cfDNA levels were significantly elevated in plasma from both burns (days 1-14 postinjury) and trauma patients (<1-72 hours) compared to healthy controls. Electrophoresis revealed a prominent nucleosome band (~150 base pairs) in both burns and trauma plasma, with nucleosome oligomers detected within ultra-early samples (<1-hour posttrauma). The density of nucleosome bands correlated with cfDNA concentrations. Microfluidic capture of circulating NET-derived chromatin demonstrated increased levels in whole blood from burns, particularly at day 1 postinjury.
CONCLUSIONS: NET-derived chromatin, cfDNA, and nucleosomes are elevated following severe burns and trauma. The dynamic changes in cDNA support their contribution to inflammation and as a key biomarker.
参考来源
- Asiri A, Hazeldine J, Moiemen N, et al. Qualitative and Quantitative Analysis of Circulating Net-Derived Chromatin and Nucleosomes in Severe Thermal and Traumatically Injured Patients. Shock. 2026. PMID: 42059827. doi:10.1097/SHK.0000000000002733
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。