文献速递复苏、休克与脓毒症儿科与产科急症

模拟院前冷水浸泡中尸袋完整性的比较研究

Body bag integrity in simulated prehospital cold water immersion: A comparison study.
PubMed 文献 · Am J Emerg Med · 2026-03-19
一句话结论模拟院前冷水浸泡降温中,7款尸体袋平均失水14.49 L,5款出现结构失效;中心拉链、带提手、较厚材质与双缝或熔合接缝失水最少。

该观察性研究针对院前热射病冷水浸泡(CWI)降温,测试7款市售尸体袋在相同模拟降温流程(地面及转移至担架、使用38 L冰水)中的表现。评估水深度、残余水量及袋体完整性与强度。结果袋体平均失水14.49 L,中位失水10.7 L;中心拉链和带提手的袋失水最少;7款中5款出现某种结构失效。作者认为较厚材质、双缝或熔合接缝、中心拉链最有益,并指出需进一步研究以确定最佳袋型。

要点

  • 7款市售尸体袋在模拟院前CWI降温中平均失水14.49 L,中位失水10.7 L。
  • 中心拉链和带提手的袋失水最少。
  • 7款袋中5款在测试中出现某种结构失效。
  • 较厚材质、双缝或熔合接缝、中心拉链为最有益特征。
  • 作者认为需进一步研究确定最适合CWI的袋型以保证患者安全与疗效。

适用人群与场景

  • 模拟院前热射病冷水浸泡降温场景,使用38 L冰水,在地面及转移至担架过程中测试尸体袋。

诊断标准与关键阈值

  • 热射病定义为核心体温>40 °C并伴终末器官损伤,最显著为中枢神经系统功能障碍。
  • CWI降温速率需达到或超过理想速率0.2 °C/min。

处置流程与药物剂量

  • 使用TEMP袋(即尸体袋)进行冷水浸泡降温,降温速率可达到或超过0.2 °C/min。

研究设计与关键结果

  • 观察性研究,测试7款市售尸体袋,每款均经相同模拟降温流程(地面及转移至担架,使用38 L冰水)。
  • 袋体平均失水14.49 L,中位失水10.7 L。
  • 中心拉链和带提手的袋失水最少。
  • 7款中5款出现某种结构失效。
  • 最有益特征为较厚袋体材质、双缝或熔合接缝、中心拉链。

证据类型、等级与局限

  • 证据类型:观察性研究。
  • 局限:作者指出需进一步研究确定最佳袋型或特征以保证患者安全与疗效。

对床旁实践的改变

  • 作者认为较厚材质、双缝或熔合接缝、中心拉链为CWI用袋最有益的特征。
  • 作者指出需进一步研究确定最佳袋型以保证患者安全与疗效。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Heat stroke is a life-threatening condition defined as core body temperature > 40 °C plus end organ damage, most notably CNS dysfunction. Standard of care has long included the use of evaporative and convective cooling techniques; however, Cold Water Immersion (CWI) has emerged as a potential new standard of care. Thermal Emergency Management Patient (TEMP) bags (ie. body bags) allow for cooling rates that meet or exceed ideal rates of 0.2 °C/min. We investigated several commercially available bags to assess which characteristics would make up the ideal TEMP bag for CWI cooling. We conducted an observational study to test the characteristics of different bags that optimize cooling for CWI by obtaining seven commercially available body bags. Each bag was put through the same real-life simulation of patient cooling, both on the ground and with movement to patient stretcher utilizing 38 L of ice water. We evaluated water depth and residual volume, as well as the integrity and strength of each bag. On average, bags lost 14.49 L of water during testing, with a median amount of water loss of 10.7 L Bags with center zippers and those with handles lost the least amount of water. Five out of the seven bags experienced some sort of structural failure. The characteristics found to be most beneficial include thicker bag material, double sewn or fused seams, and center zippers. Further research into which characteristics or specific bag would be optimal for CWI needs to be conducted to ensure patient safety and efficacy of treatment.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Young D, Wageuspack A, Boyle L, et al. Body bag integrity in simulated prehospital cold water immersion: A comparison study. Am J Emerg Med. 2026. PMID: 41886997. doi:10.1016/j.ajem.2026.03.012

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。