文献速递重症综合管理与镇静镇痛心脑血管急症

机械通气患者左心室充盈压的超声心动图评估与肺动脉导管对比:系统评价与荟萃分析

Echocardiographic assessment of left ventricular filling pressure compared to pulmonary artery catheter in mechanically ventilated patients: Systematic review and meta-analysis.
PubMed 文献 · Ann Intensive Care · 2026-01-16
一句话结论在机械通气ICU患者中,多普勒超声心动图评估左心室充盈压与肺动脉闭塞压相关,但证据质量极低,仅显示潜在价值。

该系统评价与荟萃分析纳入18项前瞻性研究(n=696例)机械通气ICU患者,比较经胸或经食管超声心动图测量的左心室充盈压指标与肺动脉导管测得的肺动脉闭塞压(PAOP)。8项研究(n=342例)进入荟萃分析,所有研究样本量均小于100例。预测PAOP≥18 mmHg时,E/A的AUROC为0.69至0.83,侧壁E/E'为0.60至0.91;E/A与PAOP的合并相关系数为0.48(95%CI 0.48-0.58),侧壁E/E'为0.72(95%CI 0.52-0.92)。研究质量从低到高不等,异质性高,总体证据等级极低。

要点

  • 在机械通气ICU患者中,侧壁E/E'与PAOP的合并相关系数为0.72(95%CI 0.52-0.92),E/A为0.48(95%CI 0.48-0.58)。
  • 预测PAOP≥18 mmHg时,E/A的AUROC为0.69至0.83,侧壁E/E'为0.60至0.91。
  • 纳入的18项前瞻性研究共696例患者,所有研究样本量均小于100例。
  • 研究质量从低到高不等,异质性高,总体证据等级被评定为极低。
  • 不同研究采用不同的PAOP截断值定义左心室充盈压升高,限制了结果的可比性。

适用人群与场景

  • ICU内接受机械通气的危重症患者。

诊断标准与关键阈值

  • 以肺动脉导管测得的肺动脉闭塞压(PAOP)作为左心室充盈压的参照标准,预测PAOP≥18 mmHg定义充盈压升高。

研究设计与关键结果

  • 系统评价与荟萃分析,初始检索3596项研究,最终纳入18项前瞻性研究(n=696例患者),其中8项研究(n=342例患者)进入荟萃分析。
  • 所有纳入研究样本量均小于100例;6项研究评估E/A比值与PAOP的关系,4项研究评估E/E'比值与PAOP的关系。
  • 预测PAOP≥18 mmHg时,E/A的AUROC为0.69至0.83,侧壁E/E'的AUROC为0.60至0.91。
  • E/A与PAOP的合并相关系数为0.48(95%CI 0.48-0.58),侧壁E/E'与PAOP的合并相关系数为0.72(95%CI 0.52-0.92)。
  • 研究质量从低到高不等,异质性高,总体证据等级被评定为极低。

证据类型、等级与局限

  • 证据类型:系统评价与荟萃分析,纳入18项前瞻性研究。
  • 证据等级:采用GRADE标准评定,总体证据等级为极低。
  • 局限:所有研究样本量小(小于100例);研究异质性高;不同研究采用不同的PAOP截断值定义左心室充盈压升高;作者指出需进一步研究以强化超声心动图在该场景中的作用。

对床旁实践的改变

  • 作者认为多普勒超声心动图在机械通气危重患者中评估左心室充盈压具有潜在价值,但受样本量小和研究异质性(包括采用不同PAOP截断值定义充盈压升高)限制,需进一步研究以强化其在该场景中的作用。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Estimating left ventricular filling pressures (LVFP) is a crucial component of hemodynamic monitoring in critically ill patients. While non-invasive techniques such as Doppler echocardiography have been validated in non-critical populations, their application in mechanically ventilated patients remains less well-documented.

OBJECTIVE: This study aims to evaluate the accuracy of Doppler echocardiography in predicting LVFP, as assessed by pulmonary artery occlusion pressure (PAOP), in mechanically ventilated patients admitted to the intensive care unit (ICU).

METHODS: We conducted a systematic review and meta-analysis of peer-reviewed studies focusing on critically ill patients undergoing mechanical ventilation in the ICU (Population-P). The intervention (I) was the assessment of LVFP using transthoracic or transesophageal echocardiography. The comparator (C) was PAOP measurement obtained via a pulmonary artery catheter. The primary outcomes (O) included the accuracy of echocardiographic measurements and their correlation with PAOP. We searched three databases (PubMed/Medline, Scopus, and Embase), screened relevant articles, synthesized the data, assessed study quality using standard tools, and graded the level of evidence with GRADE criteria. A meta-analysis was performed for comparable findings.

RESULTS: Of 3596 studies initially identified, 18 prospective studies (n = 696 patients) met the inclusion criteria, with 8 studies (n = 342 patients) included in the meta-analysis. All studies featured small sample sizes (less than 100 patients). Six studies evaluated E/A ratios, and four E/E' ratios. in relation to PAOP. The area under the receiver operating characteristic (AUROC) curve ranged from 0.69 to 0.83 for E/A and from 0.60 to 0.91 for lateral E/E' in predicting PAOP ≥ 18 mmHg. Both E/A and lateral E/E' showed a correlation with PAOP, with pooled correlation coefficients of 0.48 (95% confidence intervals [CI]: 0.48-0.58) and 0.72 (95% CI: 0.52-0.92), respectively. Study quality ranged from low to high and heterogeneity was high the overall level of evidence was deemed very low.

CONCLUSIONS: Doppler echocardiography shows potential for assessing LVFP in critically ill patients on mechanical ventilation. However, limitations such as small sample sizes and study heterogeneity, including the use of different PAOP cut-off values to define elevated LVFP, highlight the need for further research to strengthen its role in this setting.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Calicchia M, Bianchi V, Calabrese A, et al. Echocardiographic assessment of left ventricular filling pressure compared to pulmonary artery catheter in mechanically ventilated patients: Systematic review and meta-analysis. Ann Intensive Care. 2026. PMID: 41788485. doi:10.1016/j.aicoj.2025.100024

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。