根据体位与可复张性评估呼气末正压对通气血流比失调的影响:一项临床前瞻性研究
该前瞻性研究连续纳入50例中重度ARDS患者,用复张-膨胀比(R/I ratio)评估基线肺可复张性,分别在仰卧位和俯卧位下比较PEEP 5 cm H2O与PEEP 15 cm H2O对通气血流比失调、气体交换和呼吸力学的影响。R/I ratio中位数为0.60,据此区分高、低可复张性患者。高R/I比患者中,PEEP 15 cm H2O在两种体位下均减少分流而不显著增加死腔,从而改善通气血流比失调(仰卧位30.7% vs 38.0%,P<0.001;俯卧位25.7% vs 32.8%,P<0.001)。低R/I比患者中,仰卧位PEEP 15 cm H2O未改善通气血流比失调(37.8% vs 41.3%,P=0.078),俯卧位PEEP 15 cm H2O显著加重失调(35.9% vs 31.7%,P<0.001),因未能减少分流而显著增加死腔。
要点
- 中重度ARDS患者R/I ratio中位数为0.60,可据此区分高与低可复张性人群。
- 高R/I比患者:PEEP 15 cm H2O较PEEP 5 cm H2O在仰卧位降低通气血流比失调(30.7% vs 38.0%,P<0.001),俯卧位同样降低(25.7% vs 32.8%,P<0.001)。
- 低R/I比患者:仰卧位PEEP 15 cm H2O较PEEP 5 cm H2O未改善通气血流比失调(37.8% vs 41.3%,P=0.078),分流减少伴死腔显著增加。
- 低R/I比患者:俯卧位PEEP 15 cm H2O较PEEP 5 cm H2O显著加重通气血流比失调(35.9% vs 31.7%,P<0.001),未减少分流而显著增加死腔。
- 高R/I比患者中,PEEP 15 cm H2O在仰卧和俯卧位均减少分流且不显著增加死腔。
适用人群与场景
- 连续纳入的50例中重度急性呼吸窘迫综合征(ARDS)患者。
诊断标准与关键阈值
- 采用复张-膨胀比(R/I ratio)测量基线肺可复张性,中位数为0.60 [0.38, 0.72],以此区分高与低R/I比患者。
处置流程与药物剂量
- 在仰卧位依次评估PEEP 5 cm H2O和PEEP 15 cm H2O,随后在俯卧位依次评估PEEP 5 cm H2O和PEEP 15 cm H2O。
研究设计与关键结果
- 前瞻性临床研究,连续纳入50例中重度ARDS患者,评估仰卧位和俯卧位下PEEP 5 cm H2O与PEEP 15 cm H2O对通气血流比失调、气体交换和呼吸力学的影响。
- 高R/I比患者:PEEP 15 cm H2O较PEEP 5 cm H2O降低通气血流比失调,仰卧位30.7 [28.6, 36.8]% vs 38.0 [34.9, 45.4]%,P<0.001;俯卧位25.7 [21.4, 30.4]% vs 32.8 [27.5, 36.7]%,P<0.001;均减少分流而不显著增加死腔。
- 低R/I比患者:仰卧位PEEP 15 cm H2O较PEEP 5 cm H2O未改善通气血流比失调(37.8 [34.7, 42.1]% vs 41.3 [34.8, 45.4]%,P=0.078),分流减少伴死腔显著增加。
- 低R/I比患者:俯卧位PEEP 15 cm H2O较PEEP 5 cm H2O显著加重通气血流比失调(35.9 [28.3, 43.4]% vs 31.7 [24.3, 37.6]%,P<0.001),未能减少分流而显著增加死腔。
证据类型、等级与局限
- 证据类型:临床前瞻性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 对中重度ARDS患者,高R/I比者PEEP 15 cm H2O在仰卧和俯卧位均改善通气血流比失调;低R/I比者仰卧位PEEP 15 cm H2O未改善,俯卧位PEEP 15 cm H2O显著加重失调。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: High positive end-expiratory pressure (PEEP) may improve ventilation-perfusion (V/Q) mismatch in acute respiratory distress syndrome (ARDS) patients with high recruitability in supine position. However, impacts of PEEP on V/Q mismatch in prone position relative to supine position remain poorly understood. We aimed to compare PEEP effects between positions, and evaluate its relationship with lung recruitability.
METHODS: A total of 50 patients with moderate-to-severe ARDS were consecutively enrolled. Recruitment-to-inflation (R/I) ratio was used to measure baseline lung recruitability. V/Q mismatch, gas exchange, and respiratory mechanics were evaluated at PEEP 5 cm H2O and PEEP 15 cm H2O in supine position, followed by PEEP 5 cm H2O and PEEP 15 cm H2O in prone position.
RESULTS: Median R/I ratio was 0.60 [0.38, 0.72], separating patients with higher and lower R/I ratio. In patients with higher R/I ratio, PEEP 15 cm H2O (compared to PEEP 5 cm H2O) reduced shunt without significantly increasing dead space in both supine and prone positions, thereby improving V/Q mismatch (supine: 30.7 [28.6, 36.8]% at PEEP 15 cm H2O vs.38.0 [34.9, 45.4]% at PEEP 5 cm H2O, P < 0.001; prone: 25.7 [21.4, 30.4]% at PEEP 15 cm H2O vs. 32.8 [27.5, 36.7]% at PEEP 5 cm H2O, P < 0.001). However, in patients with lower R/I ratio, PEEP 15 cm H2O (compared to PEEP 5 cm H2O) in supine position did not improve V/Q mismatch (37.8 [34.7, 42.1]% at PEEP 15 cm H2O vs. 41.3 [34.8, 45.4]% at PEEP 5 cm H2O, P = 0.078), as the reduction in shunt was accompanied by a significant increase in dead space; in prone position, PEEP 15 cm H2O significantly worsened V/Q mismatch (35.9 [28.3, 43.4]% at PEEP 15 cm H2O vs. 31.7 [24.3, 37.6]% at PEEP 5 cm H2O, P < 0.001), as it failed to reduce shunt while significantly increasing dead space.
CONCLUSIONS: In patients with higher R/I ratio, PEEP 15 cm H2O improved V/Q mismatch in both supine and positions. In patients with lower R/I ratio, PEEP 15 cm H2O did not impact V/Q mismatch in supine position but significantly worsened it in prone position.
参考来源
- Zha Z, Wang Z, Cheng Q, et al. Impact of PEEP on V/Q mismatch according to patient position and recruitability: a clinical prospective study. Ann Intensive Care. 2026. PMID: 41852673. doi:10.1016/j.aicoj.2026.100046
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。