文献速递心脑血管急症重症综合管理与镇静镇痛儿科与产科急症

先天性心脏病婴儿体外循环术后早期脑多普勒与氧饱和度参数的演变:前瞻性队列研究

Immediate Postoperative Evolution of Cerebral Doppler and Saturation Parameters After Cardiopulmonary Bypass in Infants With Congenital Heart Disease: A Prospective Cohort Study.
PubMed 文献 · Crit Care Explor · 2026-02-13
一句话结论先天性心脏病婴儿体外循环术后约9.3小时大脑中动脉流速降至最低,与脑氧饱和度最低、动静脉氧差最高同时出现,可能提示相对性脑低灌注期。

本研究为加拿大单中心前瞻性观察研究,纳入15例体外循环术后机械通气的先天性心脏病新生儿和婴儿,在术后24小时内7个预设时间点行双侧大脑中动脉经颅多普勒检测,共分析87次同步测量。大脑中动脉流速最低点出现在体外循环结束后平均9.3小时(标准差1.7小时),与脑氧饱和度最低、系统动静脉氧差最高和脑组织氧摄取分数最高同时出现。较低的大脑中动脉平均流速与较高的动静脉氧差和升高的脑组织氧摄取分数相关。作者认为这些发现可能提示相对性脑低灌注期,未来研究应评估多模态脑监测指导下的靶向干预能否降低急性及长期脑损伤风险。

要点

  • 体外循环术后大脑中动脉流速最低点出现在术后平均9.3小时(标准差1.7小时),与脑氧饱和度最低、动静脉氧差最高同时出现。
  • 较低的大脑中动脉平均流速与较高的系统动静脉氧差和升高的脑组织氧摄取分数相关。
  • 研究纳入15例体外循环术后机械通气的先天性心脏病新生儿和婴儿,共分析87次同步测量。
  • 作者认为这些发现可能提示相对性脑低灌注期,未来研究应评估多模态脑监测指导的靶向干预能否降低脑损伤风险。

适用人群与场景

  • 加拿大单中心儿科心脏ICU收治的体外循环术后机械通气的先天性心脏病新生儿和婴儿,共15例。

研究设计与关键结果

  • 前瞻性观察研究,单中心,纳入15例体外循环术后机械通气的先天性心脏病新生儿和婴儿,无干预,共分析87次同步测量。
  • 体外循环结束后24小时内7个预设时间点行双侧大脑中动脉经颅多普勒检测,时间0定义为体外循环结束。
  • 大脑中动脉流速最低点出现在体外循环结束后平均9.3小时(标准差1.7小时),与脑氧饱和度最低、系统动静脉氧差最高和脑组织氧摄取分数最高同时出现。
  • 较低的大脑中动脉平均流速与较高的系统动静脉氧差和升高的脑组织氧摄取分数相关。

证据类型、等级与局限

  • 证据类型:前瞻性观察性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为体外循环术后约9小时大脑中动脉流速最低可能与相对性脑低灌注期相关,未来研究应评估多模态脑监测指导的靶向干预能否降低急性及长期脑损伤风险。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To describe temporal trends and instantaneous relationships between middle cerebral artery (MCA) cerebral blood flow velocity, cerebral oxygen saturation (Csat), cerebral fractional tissue oxygen extraction (cFTOE), and systemic arteriovenous oxygen difference (AVo2) during the first 24 hours following congenital heart disease (CHD) surgery requiring cardiopulmonary bypass (CPB).

DESIGN: Prospective observational study conducted from August 2021 to June 2022.

SETTING: Single-center pediatric cardiac ICU in Canada.

PATIENTS: Fifteen ventilated neonates and infants admitted to the PICU following CHD surgery requiring CPB.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Bilateral transcranial Doppler (TCD) assessments of the MCA were performed at seven predefined time points during the first 24 hours following CPB, with time 0 defined as the end of CPB. A total of 87 simultaneous measurements of systemic oxygen saturation, Csat, TCD-derived parameters, and AVo2 were analyzed. The nadir in MCA velocities occurred at a mean of 9.3 hours (sd, 1.7 hr) post-CPB and coincided with the lowest Csat and the highest AVo2 difference and cFTOE. Lower MCA mean velocities were associated with higher AVo2 difference and increased cFTOE.

CONCLUSIONS: In neonates and infants following CPB, MCA velocities reach its lowest point approximately 9 hours post-CPB, coinciding with the highest AVo2 difference and previously published nadir of cardiac output. These findings could suggest a period of relative cerebral hypoperfusion. Future studies should evaluate whether targeted interventions guided by multimodal cerebral monitoring can mitigate the risk of acute and long-term brain injury in this vulnerable population.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Mir M, Maitre G, Dancea A, et al. Immediate Postoperative Evolution of Cerebral Doppler and Saturation Parameters After Cardiopulmonary Bypass in Infants With Congenital Heart Disease: A Prospective Cohort Study. Crit Care Explor. 2026. PMID: 41686139. doi:10.1097/CCE.0000000000001364

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。