文献速递重症综合管理与镇静镇痛心脑血管急症

颅内压波形形态学特征作为颅内高压生物标志物的性能

Performance of Intracranial Pressure Waveform Morphological Features as Biomarkers of Intracranial Hypertension.
PubMed 文献 · Crit Care Explor · 2026-02-13
一句话结论回顾性数据显示,颅内压波形形态学特征(包括P2/P1比值)检测或预测颅内高压的能力有限,目前形式可能不适合常规临床使用。

该研究回顾了宾夕法尼亚大学两个神经重症监护病房2015年7月1日至2024年10月31日期间121例同时接受颅内压和心电监护的脑损伤患者数据。每分鐘计算7个反映峰值、振幅、频率和形态域的颅内压形态学特征,颅内高压事件定义为平均颅内压大于或等于20 mm Hg持续至少30分钟。结果显示这些特征仅在部分患者中有效检测或预测颅内高压(检测率20%至75%,预测率13%至53%),基于振幅的特征表现优于其他域,平均脉冲振幅的平均受试者工作特征曲线下面积最高为0.83(95%CI [0.77-0.88]),而P2/P1比值为0.71(95%CI [0.67-0.76])。在实时监测模拟中应用预测阈值后性能下降,平均脉冲振幅表现最佳但仍不理想,假阳性率为1.77/小时,在事件开始前30分钟、开始后15分钟和整个事件期间的颅内高压检测率分别为36%、54%和65%。作者结论认为这些特征目前形式可能不适合常规临床使用。

要点

  • 在121例脑损伤患者中,基于振幅的特征(平均脉冲振幅)检测颅内高压的AUC为0.83(95%CI [0.77-0.88]),优于P2/P1比值的0.71(95%CI [0.67-0.76])。
  • 颅内压形态学特征仅在部分患者中有效检测或预测颅内高压,检测率范围为20%至75%,预测率范围为13%至53%。
  • 在实时监测模拟中应用预测阈值后性能下降,平均脉冲振幅的假阳性率为1.77/小时,检测率在事件前30分钟为36%、事件后15分钟为54%、整个事件期间为65%。
  • 基于振幅的特征表现更好与女性性别和创伤性脑损伤诊断相关。
  • 作者结论认为这些颅内压形态学特征目前形式可能不适合常规临床使用。

适用人群与场景

  • 在宾夕法尼亚大学两个神经重症监护病房接受颅内压和心电监护的121例脑损伤患者,数据收集时间为2015年7月1日至2024年10月31日。

诊断标准与关键阈值

  • 颅内高压事件定义为平均颅内压大于或等于20 mm Hg持续至少30分钟。

研究设计与关键结果

  • 研究类型为回顾性研究,样本量121例,在宾夕法尼亚大学两个神经重症监护病房进行,人群为脑损伤患者。
  • 每分鐘计算7个颅内压形态学特征,涵盖峰值、振幅、频率和形态域。
  • 特征检测颅内高压的有效率范围为20%至75%,预测有效率范围为13%至53%。
  • 基于振幅的特征表现优于其他域,平均脉冲振幅的平均AUC为0.83(95%CI [0.77-0.88]),P2/P1比值为0.71(95%CI [0.67-0.76])。
  • 基于振幅的特征表现更好与女性性别和创伤性脑损伤诊断相关。
  • 最佳分类阈值因个体而异。
  • 在实时监测模拟中应用预测阈值后性能下降,平均脉冲振幅表现最佳但仍不理想,假阳性率为1.77/小时,颅内高压检测率在事件开始前30分钟为36%、开始后15分钟为54%、整个事件期间为65%。

证据类型、等级与局限

  • 证据类型为回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为所检验的颅内压形态学特征在检测或预测颅内高压方面效用有限,目前形式可能不适合常规临床使用。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

IMPORTANCE: Intracranial hypertension (IH) is a life-threatening condition requiring timely intervention. Morphology of the intracranial pressure (ICP) waveform, especially the ratio of the second to the first ICP waveform peaks (P2/P1 ratio), may serve as a biomarker for IH.

OBJECTIVES: This study evaluates the potential of the P2/P1 ratio and other morphological features to detect and predict IH and their utility in clinical practice.

DESIGN, SETTING, AND PARTICIPANTS: Retrospective data from 121 patients with brain injury who underwent both ICP and electrocardiographic monitoring across two neurointensive care units at the University of Pennsylvania were collected between July 1, 2015, and October 31, 2024.

MAIN OUTCOMES AND MEASURES: Seven ICP morphological features reflecting peak, amplitude, frequency, and shape domains were calculated every minute. IH events were defined as mean ICP greater than or equal to 20 mm Hg for at least 30 minutes.

RESULTS: Features effectively detected or predicted IH in only a subset of patients, ranging from 20% to 75% for detection and 13% to 53% for prediction. Amplitude-based features outperformed features in other domains, with mean pulse amplitude (AMP) achieving the highest average area under the receiver operating characteristic curve of 0.83 (95% CI, [0.77-0.88]), compared with 0.71 (95% CI [0.67-0.76]) for the P2/P1 ratio. Better amplitude-based feature performance was associated with female sex and traumatic brain injury diagnoses. Optimal classification thresholds varied across individuals. Applying predicted thresholds in real-time monitoring simulations led to reduced performance. AMP achieved the best, albeit suboptimal, performance, with a false-positive rate of 1.77/hr, and IH detection rates of 36%, 54%, and 65% within 30 minutes before onset, 15 minutes after onset, and over the full event duration, respectively.

CONCLUSIONS AND RELEVANCE: The ICP morphological features examined demonstrated limited utility in detecting or predicting IH and, in their current form, may not be suitable for routine clinical use.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Shi H, Young B, Schneider ALC, et al. Performance of Intracranial Pressure Waveform Morphological Features as Biomarkers of Intracranial Hypertension. Crit Care Explor. 2026. PMID: 41686137. doi:10.1097/CCE.0000000000001379

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。