文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

膈肌生理相似指数(DPSI):一种用于急性呼吸衰竭经鼻高流量氧疗调节的斑点追踪超声新指标

Diaphragm physiological similarity index (DPSI): a de Novo speckle-tracking ultrasound metric for HFNC adjustment in acute respiratory failure.
PubMed 文献 · Crit Care · 2026-02-26
一句话结论DPSI是一种可行且可重复的斑点追踪超声指标,能区分健康与受损的膈肌运动轨迹,并随HFNC流量阶梯调整而升高,可能为个体化HFNC管理提供补充生理信息。

该前瞻性观察研究纳入103名参与者:45名健康志愿者、38名ICU患者用于评估可重复性、20名急性呼吸衰竭(ARF)患者接受预设的阶梯式HFNC流量调整方案。通过斑点追踪超声获取膈肌位移-时间曲线,基于健康参考波形推导出DPSI。结果显示健康成人曲线平滑、对称、单峰,而ARF患者曲线钝化、不规则、多变;平均吸气速度(ICC=0.87)、峰值位移(ICC=0.69)、DPSI(ICC=0.75)均具有良好的可重复性。DPSI在阶梯式HFNC流量调整中升高,许多患者在中间流量(30–40 L/min)时观察到较高值;DPSI与ROX指数(R²=0.62,p<0.001)和峰值膈肌位移(R²=0.60,p<0.001)相关,反映其生理相关性。作者认为DPSI可能为个体化HFNC管理提供补充生理信息,未来需多中心研究评估其增量价值及与患者中心结局的关联。

要点

  • 在20例ARF患者进行预设阶梯式HFNC流量调整时,DPSI随流量调整而升高,许多患者在中间流量30–40 L/min时观察到较高值。
  • DPSI与ROX指数相关(R²=0.62,p<0.001),与峰值膈肌位移相关(R²=0.60,p<0.001)。
  • DPSI的可重复性ICC=0.75,平均吸气速度ICC=0.87,峰值位移ICC=0.69,均显示良好可重复性。
  • 健康成人膈肌位移-时间曲线平滑、对称、单峰,而ARF患者呈钝化、不规则、多变轨迹,DPSI可区分二者。
  • 作者认为DPSI可能作为补充生理信息,与已有指标和临床评估一起指导个体化HFNC管理,未来需多中心研究评估其增量价值。

适用人群与场景

  • 研究纳入45名健康志愿者、38名ICU患者(用于可重复性评估)和20名接受预设阶梯式HFNC流量调整方案的急性呼吸衰竭(ARF)患者。
  • 研究场景为ICU患者及接受HFNC治疗的ARF患者。

处置流程与药物剂量

  • 对20例ARF患者实施预设的阶梯式HFNC流量调整方案,并同步进行斑点追踪超声获取膈肌位移-时间曲线以计算DPSI。

研究设计与关键结果

  • 研究类型为前瞻性观察研究,纳入103名参与者:45名健康志愿者、38名ICU患者(可重复性评估)、20名ARF患者(阶梯式HFNC流量调整)。
  • 健康成人膈肌位移-时间曲线平滑、对称、单峰;ARF患者曲线钝化、不规则、多变。
  • 可重复性:平均吸气速度ICC=0.87,峰值位移ICC=0.69,DPSI ICC=0.75。
  • DPSI在阶梯式HFNC流量调整中升高,许多患者在中间流量(30–40 L/min)时观察到较高值。
  • DPSI与ROX指数相关(R²=0.62,p<0.001),与峰值膈肌位移相关(R²=0.60,p<0.001)。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为DPSI可能作为补充生理信息,与已有指标和临床评估一起指导个体化HFNC管理。
  • 研究显示DPSI在阶梯式HFNC流量调整中升高,许多患者在中间流量30–40 L/min时观察到较高值,但原文未给出基于DPSI调整流量的具体阈值或方案。
  • 原文结论指出未来需多中心研究评估DPSI的增量价值及其与患者中心结局的关联。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Individualized diaphragm-protective respiratory support remains challenging, particularly during high-flow nasal cannula (HFNC) therapy. We developed the diaphragm physiological similarity index (DPSI) using speckle-tracking ultrasound to quantify diaphragmatic coordination and explore its potential to inform HFNC flow adjustment in acute respiratory failure (ARF).

METHODS: In this prospective observational study, 103 participants were enrolled: 45 healthy volunteers, 38 intensive care unit (ICU) patients for reproducibility assessment, and 20 ARF patients undergoing a prespecified stepwise HFNC flow adjustment protocol. Diaphragmatic displacement–time curves were acquired, and DPSI was derived from healthy reference waveforms. Reproducibility, feasibility, and physiological responsiveness to HFNC flow adjustments were evaluated and correlated with peak diaphragmatic excursion and the ROX (respiratory rate-oxygenation) index.

RESULTS: Healthy adults exhibited smooth, symmetric, and unimodal displacement-time curves, whereas ARF patients showed blunted, irregular, and variable trajectories. Mean inspiratory velocity (ICC = 0.87); peak displacement (ICC = 0.69); DPSI (ICC = 0.75) showed good reproducibility. DPSI increased during stepwise HFNC flow adjustments, with higher values commonly observed at intermediate flows (30–40 L/min) in many patients. DPSI was associated with the ROX index (R² = 0.62, p < 0.001) and peak diaphragmatic excursion (R² = 0.60, p < 0.001), reflecting physiological relevance.

CONCLUSION: DPSI is a feasible and reproducible speckle-tracking ultrasound metric that quantifies diaphragmatic motion patterns and distinguishes healthy from impaired contraction trajectories. DPSI responds to stepwise HFNC flow adjustments and may provide complementary physiological information to guide individualized HFNC management alongside established indices and clinical assessment. Future multicenter studies should evaluate its incremental value and association with patient-centered outcomes.

TRIAL REGISTRATION: ClinicalTrials.gov (NCT06996665, 3 May 2025).

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-026-05899-w.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. He R, Mao X, Chen W, et al. Diaphragm physiological similarity index (DPSI): a de Novo speckle-tracking ultrasound metric for HFNC adjustment in acute respiratory failure. Crit Care. 2026. PMID: 41749337. doi:10.1186/s13054-026-05899-w

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。