本研究为混合方法前瞻性队列研究,对2017至2022年四家医院院内心脏骤停复苏后团队成员进行复盘调查,共纳入313例有完整除颤器与调查数据的院内心脏骤停事件。133例(42.5%)报告存在障碍。报告障碍时,按压分数≥80%的比值比为0.55(95%CI:0.35-0.89);最长按压中断时间增加3.21秒(95%CI:-1.91至8.38),未达统计学显著;指南合规按压频率的比值比为1.02(95%CI:0.64-1.62)。沟通障碍(而非团队合作和按压质量障碍)与指南合规按压频率的较低比值比相关(OR=0.53,95%CI:0.29-0.95)。
要点
- 313例院内心脏骤停中133例(42.5%)报告存在障碍。
- 报告障碍时按压分数≥80%的比值比为0.55(95%CI:0.35-0.89)。
- 报告障碍时最长按压中断时间增加3.21秒(95%CI:-1.91至8.38),未达统计学显著。
- 沟通障碍与指南合规按压频率的较低比值比相关(OR=0.53,95%CI:0.29-0.95)。
- 团队合作和按压质量障碍与指南合规按压频率无显著关联(OR=1.02,95%CI:0.64-1.62)。
适用人群与场景
- 2017至2022年四家医院的院内心脏骤停复苏事件,纳入有完整除颤器与复盘调查数据的313例。
研究设计与关键结果
- 研究类型为混合方法前瞻性队列研究,纳入313例院内心脏骤停,来自四家医院,2017至2022年。
- 133例(42.5%)事件报告存在障碍。
- 报告障碍时按压分数≥80%的比值比为0.55(95%CI:0.35-0.89)。
- 报告障碍时最长按压中断时间增加3.21秒(95%CI:-1.91至8.38),未达统计学显著。
- 报告障碍时指南合规按压频率的比值比为1.02(95%CI:0.64-1.62)。
- 沟通障碍与指南合规按压频率的较低比值比相关(OR=0.53,95%CI:0.29-0.95),团队合作和按压质量障碍无此关联。
证据类型、等级与局限
- 证据类型为混合方法前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为沟通障碍似乎是按压质量指标关联的主要驱动因素。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the association between barriers reported by cardiac arrest team members and chest compression quality during in-hospital cardiac arrest (IHCA) cardiopulmonary resuscitation (CPR) attempts.
METHODS: This is a mixed-methods prospective cohort study. We sent post-event debriefing surveys to cardiac arrest team members following resuscitation attempts across four hospitals from 2017 to 2022. Likert-scale ratings and qualitative analysis of free-text comments were used to categorize events as having barriers present. We investigated the association between barriers and key chest compression quality metrics measured from defibrillators. The association was further examined for three predefined barrier categories: CPR quality, teamwork and communication.
RESULTS: We included 313 IHCAs with complete defibrillator and survey data, of which 133 (42.5%) events had barriers reported. The odds ratio (OR) of having a CCF ≥80% was 0.55 (95% CI: 0.35-0.89) when barriers were reported. IHCAs with any reported barriers had an increase in the longest pause duration of 3.21 s (95% CI: -1.91 to 8.38) compared to IHCAs without reported barriers, while the OR for guideline-compliant compression rate was 1.02 (95% CI: 0.64-1.62). Communication barriers, but not teamwork and CPR quality barriers, were associated with lower odds of guideline-compliant chest compression rates (OR = 0.53; 95% CI: 0.29-0.95).
CONCLUSION: Barriers were frequently reported during IHCA and were associated with a significantly lower odds for a CCF ≥80% but not significantly associated with the longest pause duration and guideline-compliant chest compression rates. The category of communication barriers appeared to be the main driver of associations with chest compression quality metrics.