文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

无需屏气的盐水造影电阻抗断层成像肺灌注评估:一项随机交叉试验

Lung perfusion estimation by saline-contrast EIT without breath hold: a randomized cross-over trial.
PubMed 文献 · Crit Care · 2026-01-05
一句话结论在机械通气ICU患者中,无需屏气的低通滤波盐水造影EIT方法获得的肺灌注图像与常规屏气法总体一致(中位像素相关系数r=0.94)。

本研究开发并验证了一种无需屏气的对比增强电阻抗断层成像(EIT)方法,利用低通滤波在床旁评估机械通气ICU患者的区域肺灌注。采用随机交叉试验设计,每例患者经中心静脉导管分别于呼气末暂停(屏气)和持续机械通气(非屏气)时接受两次10 mL 10% NaCl团注。非屏气法在灌注分析中使用0.17 Hz低通滤波器去除呼吸干扰。最终分析纳入20例机械通气ICU患者,屏气与非屏气法像素级灌注相关性总体一致性良好(中位r=0.94,IQR 0.90-0.97),整体V/Q匹配百分比、死腔百分比和分流百分比两法相当,非屏气法阻抗下降持续时间显著更短(5.3 s vs 6.1 s,p=0.008)。

要点

  • 20例机械通气ICU患者中,屏气与非屏气盐水造影EIT像素级灌注相关性中位r=0.94(IQR 0.90-0.97)。
  • 两法整体V/Q匹配百分比、死腔百分比和分流百分比相当。
  • 非屏气法阻抗下降持续时间显著短于屏气法(5.3 s vs 6.1 s,p=0.008)。
  • 非屏气法在灌注分析中使用0.17 Hz低通滤波器去除呼吸干扰。
  • 每例患者经中心静脉导管接受两次10 mL 10% NaCl团注,分别于呼气末暂停和持续机械通气时进行。

适用人群与场景

  • 机械通气ICU患者,最终分析纳入20例。

处置流程与药物剂量

  • 每例患者经中心静脉导管接受两次10 mL 10% NaCl团注,分别于呼气末暂停(屏气)和持续机械通气(非屏气)时进行。
  • 非屏气法在灌注分析中使用0.17 Hz低通滤波器去除呼吸干扰。

研究设计与关键结果

  • 随机交叉试验,最终分析纳入20例机械通气ICU患者;每例患者接受两次10 mL 10% NaCl团注,分别于呼气末暂停和持续机械通气时进行。
  • 屏气与非屏气法像素级灌注相关性中位r=0.94(IQR 0.90-0.97)。
  • 两法整体V/Q匹配百分比、死腔百分比和分流百分比相当。
  • 非屏气法阻抗下降持续时间显著短于屏气法(5.3 s vs 6.1 s,p=0.008)。

证据类型、等级与局限

  • 证据类型:随机交叉试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 非屏气对比增强EIT方法可提供与常规屏气法一致的肺灌注图像,扩展EIT适用于不能耐受屏气的患者,并可能获得更符合生理的结果(作者认为)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: This study aimed to develop and validate a non-breath-holding contrast-enhanced electrical impedance tomography (EIT) method using low-pass filtering for bedside assessment of regional lung perfusion in mechanically ventilated ICU patients.

METHODS: This was a randomized cross-over trial. Each patient received two 10 mL 10% NaCl bolus injections via a central venous catheter, performed respectively during an end-expiratory pause (apnea) and during ongoing mechanical ventilation (non-apnea). In the non-apnea method, a 0.17 Hz low-pass filter was used to remove respiratory interference during perfusion analysis. Pixel-wise correlation was assessed using Spearman correlation analysis.

RESULTS: 20 mechanically ventilated ICU patients were included in the final analysis. Pixel-wise perfusion correlation between apnea and non-apnea methods showed good overall consistency (median r = 0.94, IQR 0.90-0.97). Global V/Q match%, dead space%, and shunt% were comparable between the two methods. The impedance drop duration was significantly shorter in the non-apnea method (5.3 s vs. 6.1 s, p = 0.008).

CONCLUSION: The non-apnea contrast-EIT method provides consistent lung perfusion images with the conventional apnea method, expanding EIT applicability to patients intolerant to apnea and potentially yielding more physiologically realistic results.

来源:Crit Care,查看原文。版权归原作者所有。