文献速递心脑血管急症复苏、休克与脓毒症

连锁超市部署自动体外除颤器

Deployment of automated external defibrillators by a supermarket chain.
PubMed 文献 · Am J Emerg Med · 2026-01-03
一句话结论多州零售连锁92个月前瞻性观察:396次AED取用/应用、112次事件中放电157次,部分放电患者存活出院,作者认为员工CPR/AED培训项目合理。

该研究为92个月前瞻性观察性研究,覆盖多州1358家零售门店及二十余处仓库/办公室,记录员工CPR/AED培训后AED取用/应用、CPR实施、放电次数及患者和现场特征。共报告396次AED取用/应用(每月>4次),75%发生在店内;294人接受基础CPR和/或AED放电(每月>3例),多由店员实施。112次事件中AED放电157次(每月>1例),71%为一次放电。某州回顾性亚组分析中37例可除颤病例匹配到医院结局记录,多数(至少19例确认)存活出院。作者认为AED安装和员工培训似乎合理,鼓励同类企业采纳/研究类似项目。

要点

  • 92个月多州零售连锁前瞻性观察:报告396次AED取用/应用(每月>4次),75%发生在店内,其余在停车场/人行道/其他场所。
  • 294人(1-93岁,74%男性)接受基础CPR和/或AED放电(每月>3例),多由店员实施;CPR患者中位年龄男60岁(IQR 45-70)、女58岁(IQR 38-68)。
  • 112次事件中AED放电157次(每月>1例):71%一次、20%两次、9%三次、1例四次;放电患者80%男性,年龄32-90岁,男中位62岁(IQR 55-70)、女61岁(IQR 55-65)。
  • 某州回顾性亚组分析37例可除颤病例匹配医院结局记录,多数(至少19例确认)存活出院。
  • 作者认为AED安装和员工CPR/AED培训似乎合理,鼓励同类企业全国范围采纳/研究类似员工项目。

适用人群与场景

  • 多州零售连锁企业场所内可能发生心肺骤停的倒地人员,覆盖1358家零售门店及二十余处仓库/办公室。

处置流程与药物剂量

  • 员工接受CPR/AED使用培训,在企业场所内对倒地人员实施基础CPR和/或使用AED。

研究设计与关键结果

  • 研究类型:前瞻性92个月观察性研究,覆盖多州大型零售连锁1358家门店及二十余处仓库/办公室。
  • 共报告396次AED取用/应用(每月>4次),75%发生在店内,其余在停车场/人行道/其他场所。
  • 294人(年龄1-93岁,74%男性)接受基础CPR和/或AED放电(每月>3例),多由店员实施;CPR患者中位年龄男60岁(IQR 45-70)、女58岁(IQR 38-68)。
  • 112次事件中AED放电157次(每月>1例):71%一次、20%两次、9%三次、1例四次;放电患者80%男性,年龄32-90岁,男中位62岁(IQR 55-70)、女61岁(IQR 55-65)。
  • 某州回顾性亚组分析37例可除颤病例匹配医院结局记录,多数(至少19例确认)存活出院。

证据类型、等级与局限

  • 证据类型:前瞻性观察性研究;原文未报告证据等级或推荐强度。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对于该多州零售连锁,AED安装和员工CPR/AED培训似乎合理,因全系统AED取用/应用频繁且常涉及与许多患者存活相关的除颤放电。
  • 作者鼓励同类企业全国范围采纳/研究类似员工项目。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Automated external defibrillator (AED) installation has become commonplace in various public locations. However, AED retrievals involving actual shocks may still be very infrequent in many settings despite significant initial/ongoing costs for equipment acquisition, pad/battery expiry replacements and initial/refresher training for designated rescuers. The purpose here was to track frequencies of AED/CPR applications and shocks delivered following AED installations and related employee training throughout a multi-state retail store chain.

DESIGN: Prospective 92-month observational study conducted across a large retail chain to document frequencies of AED device retrievals/applications, CPR performance, shocks delivered, and respective patient and scene characteristics.

SETTING: 1358 retail stores and two-dozen warehouses/offices located in multiple states.

SUBJECTS: Persons collapsing with possible cardiopulmonary arrest on corporate properties.

INTERVENTIONS: AED installation and on-going training of employees in CPR/AED use.

RESULTS: Among 396 reported AED retrievals/applications (>4/month), 75 % occurred inside stores and the remainder in parking lots/sidewalks/other venues. Among these, 294 persons (ages 1-93 years; 74 % men) received basic CPR and/or AED shocks (>3 cases/month), performed most often by store employees. CPR-patient median age was 60 years (IQR:45-70) for men and 58 (IQR:38-68) for women. AEDs delivered 157 shocks during 112 events (>1 case/month); 71 % involved one shock, 20 % two, 9 % three and one involved four shocks. Documented ages for shocked patients (80 % men) ranged 32-90 years with men's median age 62 (IQR:55-70) and women's 61 (IQR:55-65). In one state's retrospective sub-analysis of shockable cases, hospital outcome records were matched to 37 patients with the majority (at least 19 confirmed) surviving to successful hospital discharge.

CONCLUSIONS: For this multi-state retail chain, AED installation and employee CPR/AED training appeared to be well-justified considering that AEDs were retrieved/applied frequently systemwide, quite often involving defibrillatory shocks that were associated with survival for many patients. Investigators encourage comparable businesses to adopt/study similar employee-based programs nationwide.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Scheppke KA, Pepe PE, Crowe RP, et al. Deployment of automated external defibrillators by a supermarket chain. Am J Emerg Med. 2026. PMID: 41518723. doi:10.1016/j.ajem.2025.12.033

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。