文献速递复苏、休克与脓毒症

院外心脏骤停中胸外按压延迟:颈动脉与剑突下床旁超声比较

Delays in chest compressions during out-of-hospital cardiac arrest: carotid versus subxiphoid point of care ultrasound.
PubMed 文献 · Resuscitation · 2025-12-30
一句话结论院外心脏骤停时,急救员用颈动脉床旁超声判断脉搏比剑突下视图更常获得满意图像且按压暂停超过10秒更少。

该观察性研究在一个郊区第三方急救服务机构(每年约90,000次出警)比较急救员在院外心脏骤停中采用颈动脉与剑突下床旁超声判断脉搏。共分析107例患者的248次床旁超声记录,急救员在同一患者交替使用两种视图。总体73%(n=195)的按压暂停<10秒,62%(n=153)获得满意视图。颈动脉视图较剑突下视图更常实现按压暂停<10秒(83% vs 39%)和满意视图(83% vs 63%)。

要点

  • 颈动脉床旁超声较剑突下视图更常获得满意视图:83% vs 63%。
  • 颈动脉床旁超声较剑突下视图更常实现按压暂停<10秒:83% vs 39%。
  • 总体73%(n=195)的按压暂停<10秒,62%(n=153)获得满意视图。
  • 图像质量评估显示高组间信度(kappa=0.85)和93%的一致性。

适用人群与场景

  • 院外心脏骤停患者,由郊区第三方急救服务机构(每年约90,000次出警)的急救员进行心肺复苏。

研究设计与关键结果

  • 观察性研究,共分析107例患者的248次床旁超声记录,急救员在同一患者交替使用颈动脉和剑突下视图。
  • 总体73%(n=195)的按压暂停<10秒,62%(n=153)获得满意视图。
  • 颈动脉视图较剑突下视图更常实现按压暂停<10秒(83% vs 39%)。
  • 颈动脉视图较剑突下视图更常获得满意视图(83% vs 63%)。
  • 图像质量评估显示高组间信度(kappa=0.85)和93%的一致性。

证据类型、等级与局限

  • 证据类型:观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在院外心脏骤停中,急救员使用颈动脉床旁超声判断脉搏可能较剑突下视图更常获得满意图像并减少按压暂停超过10秒的情况。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Point-of-care cardiac ultrasonography (POCUS) is commonly used for pulse determination in cardiac arrest. It is unknown whether pulse determination using carotid artery POCUS can be obtained more quickly and successfully than with the subxiphoid view in the prehospital environment. Our objective was to compare carotid and subxiphoid pulse determination by paramedics during out-of-hospital cardiac arrest (OHCA). We hypothesize that prehospital carotid POCUS views may be obtained more quickly and successfully than the subxiphoid approach.

METHODS: We conducted an observational study comparing carotid and subxiphoid POCUS for pulse determination during OHCA among a suburban, third-service emergency medical services (EMS) agency (90,000 activations per year). Videos were recorded throughout each cardiopulmonary resuscitation (CPR) pause, and paramedics alternated carotid and subxiphoid views on the same patient. Videos were evaluated for view adequacy, interrater reliability and agreement assessed. Differences in view adequacy and compression pause duration between carotid and subxiphoid POCUS approaches were analyzed. McNemar's test was used to compare the proportion of adequate views and compression pauses.

RESULTS: A total of 248 POCUS recordings from 107 patients were analyzed. Image quality was assessed for adequacy, demonstrating high interrater reliability (kappa = 0.85) and 93 % agreement. Overall, 73 % (n = 195) had pause lengths <10 s, and 62 % (n = 153) had an adequate view. Compression pauses <10 s, and adequate views were achieved more frequently using carotid than subxiphoid POCUS (83 % vs. 39 % and 83 % vs. 63 %, respectively).

CONCLUSION: Paramedic-obtained carotid POCUS demonstrated a significant increase in view adequacy and fewer extended CPR pauses, as compared to subxiphoid views.

来源:Resuscitation,查看原文。版权归原作者所有。