指南与共识儿科与产科急症呼吸衰竭与机械通气

ACR适宜性标准:儿童摄入或误吸异物

ACR Appropriateness Criteria® Ingested or Aspirated Foreign Body-Child.
指南 / 共识 · J Am Coll Radiol · 2026-01-01
一句话结论美国放射学会(ACR)适宜性标准指出:疑似儿童摄入或误吸异物时,颈部、胸部、腹部和盆腔X线摄影通常适宜作为初始影像;若高度怀疑可透X线异物,可加做低剂量非增强胸部CT。

该指南针对儿童摄入或误吸异物这一常见急诊就诊原因,按三种临床情境给出影像学适宜性推荐。情境1(疑似摄入或误吸异物,初始影像):颈、胸、腹、盆腔X线摄影通常适宜;高度怀疑可透X线异物时,低剂量非增强胸部CT也可适宜。情境2(疑似摄入异物,初始X线阴性,下一步影像):非增强胸部CT通常适宜,透视食管造影或腹盆腔CT也可适宜;已知摄入水珠时腹部超声可能有帮助。情境3(疑似误吸异物,初始X线阴性,下一步影像):非增强胸部CT通常适宜,侧卧位胸片和透视检查通常不适宜。该标准由多学科专家组每年审查,采用GRADE等方法评价证据,证据不足时可依据专家意见形成推荐。

要点

  • 疑似儿童摄入或误吸异物,初始影像选颈、胸、腹、盆腔X线摄影通常适宜。
  • 高度怀疑可透X线异物时,低剂量非增强胸部CT也可适宜。
  • 疑似摄入异物且初始X线阴性,非增强胸部CT通常适宜,透视食管造影或腹盆腔CT也可适宜。
  • 已知摄入水珠时,腹部超声可能有帮助。
  • 疑似误吸异物且初始X线阴性,非增强胸部CT通常适宜,侧卧位胸片和透视检查通常不适宜。

适用人群与场景

  • 适用于急诊就诊的疑似摄入或误吸异物的儿童。

处置流程与药物剂量

  • 情境1(疑似摄入或误吸异物,初始影像):颈、胸、腹、盆腔X线摄影通常适宜;高度怀疑可透X线异物时,低剂量非增强胸部CT也可适宜。
  • 情境2(疑似摄入异物,初始X线阴性,下一步影像):非增强胸部CT通常适宜;透视食管造影或腹盆腔CT也可适宜;已知摄入水珠时,腹部超声可能有帮助。
  • 情境3(疑似误吸异物,初始X线阴性,下一步影像):非增强胸部CT通常适宜;侧卧位胸片和透视检查通常不适宜。

研究设计与关键结果

  • 美国放射学会(ACR)适宜性标准针对儿童摄入或误吸异物制定三个临床情境的影像学适宜性推荐,由多学科专家组每年审查,采用GRADE等方法评价证据,证据不足时可依据专家意见形成推荐。

证据类型、等级与局限

  • 证据类型:指南(美国放射学会适宜性标准);采用GRADE等方法评价证据,证据不足时以专家意见为主要依据。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对疑似摄入或误吸异物的儿童,初始影像可按指南选择颈、胸、腹、盆腔X线摄影;高度怀疑可透X线异物时可考虑低剂量非增强胸部CT。
  • 初始X线阴性但临床仍怀疑摄入异物时,非增强胸部CT通常适宜;已知摄入水珠时腹部超声可能有帮助。
  • 初始X线阴性但临床仍怀疑误吸异物时,非增强胸部CT通常适宜,侧卧位胸片和透视检查通常不适宜。

指南或共识出处

  • 美国放射学会(ACR)适宜性标准:儿童摄入或误吸异物(ACR Appropriateness Criteria® Ingested or Aspirated Foreign Body-Child)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Ingestion or aspiration of foreign bodies (FBs) is a common reason for pediatric emergency department visits. In this document, three variants were developed. In Variant 1 (suspect ingested or aspirated FB, initial imaging), neck, chest, abdomen, and pelvis radiographs are usually appropriate to identify the presence and location of a swallowed or inhaled FB. Low-dose noncontrast chest CT may also be appropriate when there is high suspicion for radiolucent FB. In Variant 2 (suspect ingested FB, initial radiographs negative, next imaging study), chest CT without contrast is usually appropriate, although fluoroscopic esophagram or CT abdomen and pelvis may be appropriate. If known ingested water beads, abdomen ultrasound may be helpful. In Variant 3 (suspect aspirated FB, initial radiographs negative, next imaging study), CT chest without contrast is usually appropriate while decubitus chest radiographs and fluoroscopy studies are usually not appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

参考来源

  1. Meyers ML, Moore MM, Baker JB, et al. ACR Appropriateness Criteria® Ingested or Aspirated Foreign Body-Child. J Am Coll Radiol. 2026. PMID: 41485865. doi:10.1016/j.jacr.2025.10.028

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。