文献速递重症综合管理与镇静镇痛

重症监护病房数字智能多模态交接班系统的开发与应用

[Development and application of intensive care unit digital intelligence multimodal shift handover system].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2025-01-01
一句话结论ICU数字智能多模态交接班系统可缩短交接班时间、提高交接班质量并提升医护沟通满意度。

该研究成立由1名科主任、1名护士长、3名信息技术工程师、3名护士和2名医生组成的研发团队,基于香农-韦弗线性传输模型开发了ICU数字智能多模态交接班系统,整合自动数据采集、智能动态监测、多维病情分析和可视化报告功能,通过云平台采集多参数生命体征监护仪、输液泵、呼吸机等设备数据,并采用人工智能算法标准化分析数据并提供个性化建议。研究采用自身前后对照方法,比较应用前(2023年12月至2024年3月,传统口头床旁交接班)与应用后(2024年6月至2025年3月)的交接班时间、交接班质量(护理交接班评价量表评分)和医护沟通满意度(ICU医护量表评分),并调查护士对交接班系统的满意度(临床护理信息系统有效性评价量表评分)。结果显示,应用后交接班时间显著缩短[分钟:20(15,25)vs. 30(22,40)],交接班质量显著提高[评分:84.0(78.0,88.5)vs. 71.0(55.0,79.0)],医护沟通满意度也显著提高(评分:84.58±6.79 vs. 74.50±11.30),差异均有统计学意义(均P<0.05)。护士系统有效性评价量表评分为102.30±10.56,表明护士对该系统满意度很高。

要点

  • 应用ICU数字智能多模态交接班系统后,交接班时间由30(22,40)分钟缩短至20(15,25)分钟,差异有统计学意义(P<0.05)。
  • 应用后交接班质量评分由71.0(55.0,79.0)分提高至84.0(78.0,88.5)分,差异有统计学意义(P<0.05)。
  • 应用后医护沟通满意度评分由74.50±11.30分提高至84.58±6.79分,差异有统计学意义(P<0.05)。
  • 护士对系统的有效性评价量表评分为102.30±10.56分,表明护士满意度很高。
  • 该系统基于香农-韦弗线性传输模型开发,整合自动数据采集、智能动态监测、多维病情分析和可视化报告功能。

适用人群与场景

  • ICU交接班场景,涉及护士与医生之间的交接班。

研究设计与关键结果

  • 研究类型为自身前后对照研究,比较传统口头床旁交接班(2023年12月至2024年3月)与ICU数字智能多模态交接班系统(2024年6月至2025年3月)的应用效果。
  • 交接班时间:应用前30(22,40)分钟 vs. 应用后20(15,25)分钟,应用后显著缩短(P<0.05)。
  • 交接班质量评分(护理交接班评价量表):应用前71.0(55.0,79.0)分 vs. 应用后84.0(78.0,88.5)分,应用后显著提高(P<0.05)。
  • 医护沟通满意度评分(ICU医护量表):应用前74.50±11.30分 vs. 应用后84.58±6.79分,应用后显著提高(P<0.05)。
  • 护士对系统的有效性评价量表评分为102.30±10.56分,表明护士满意度很高。

证据类型、等级与局限

  • 证据类型:自身前后对照研究(质量改进项目)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,应用ICU数字智能多模态交接班系统可缩短交接班时间、提高交接班质量并提升医护沟通满意度,护士对该系统满意度高。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To develop a digital intelligent multimodal shift handover system for the intensive care unit (ICU) and evaluate its application effect in ICU shift handovers.

METHODS: A research and development team was established, consisting of 1 department director, 1 head nurse, 3 information technology engineers, 3 nurses, and 2 doctors. Team members were assigned responsibilities including overall coordination and planning, platform design and maintenance, pre-application training, collection and organization of clinical feedback, and research investigation respectively. A digital intelligent multimodal shift handover system was developed for ICU based on the Shannon-Weaver linear transmission model. This innovative system integrated automated data collection, intelligent dynamic monitoring, multidimensional condition analysis and visual reporting functions. A cloud platform was used to gather data from multi-parameter vital signs monitors, infusion pumps, ventilators and other devices. Artificial intelligence algorithms were employed to standardize and analyze the data, providing personalized recommendations for healthcare professionals. A self-controlled before-after method was adopted. Before the application of the ICU digital intelligent multimodal shift handover system (from December 2023 to March 2024), the traditional verbal bedside handover was used; from June 2024 to March 2025, the ICU digital intelligent multimodal shift handover system was applied for shift handovers. Questionnaires before the application of the shift handover system were collected in April 2024, and those after the application were collected in April 2025. The shift handover time, handover quality (scored by the nursing handover evaluation scale), satisfaction with doctor-nurse communication (scored by the ICU doctor-nurse scale) before and after the application of the handover system were compared, and nurses' satisfaction with the shift handover system (scored by the clinical nursing information system effectiveness evaluation scale) was investigated.

RESULTS: After the application of the ICU digital intelligent multimodal shift handover system, the shift handover time was significantly shorter than that before the application [minutes: 20 (15, 25) vs. 30 (22, 40)], the handover quality was significantly higher than that before the application [score: 84.0 (78.0, 88.5) vs. 71.0 (55.0, 79.0)], and the satisfaction with doctor-nurse communication was also significantly higher than that before the application (score: 84.58±6.79 vs. 74.50±11.30). All differences were statistically significant (all P < 0.05). In addition, the nurses' system effectiveness evaluation scale score was 102.30±10.56, which indicated that nurses had a very high level of satisfaction with the ICU digital intelligent multimodal shift handover system.

CONCLUSIONS: The application of the ICU digital intelligent multimodal shift handover system can shorten the shift handover time, improve the handover quality, and enhance the satisfaction with doctor-nurse communication. Nurses have a high level of satisfaction with this system.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Bai X, Chang L, Fang W, et al. [Development and application of intensive care unit digital intelligence multimodal shift handover system]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 41331890. doi:10.3760/cma.j.cn121430-20250624-00601

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。